Measurement and Evaluation of the Bioelectrical Impedance of the Human Body by Deconvolution of a Square Wave

被引:3
|
作者
Tseng, Yuhwai [1 ]
Su, Chauchin [2 ]
Liu, Chien-Nan Jimmy [1 ]
机构
[1] Natl Cent Univ, Dept Elect Engn, Jhongli 320, Taiwan
[2] Natl Chiao Tung Univ, Dept Elect & Control Engn, Hsinchu 300, Taiwan
来源
IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS | 2010年 / E93D卷 / 06期
关键词
body impedance; square test waveform; deconvolution;
D O I
10.1587/transinf.E93.D.1656
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this study, we use the deconvolution of a square test stimulus to replace a series of sinusoidal test waveforms with different frequencies to simplify the measurement of human body impedance. The average biological impedance of body parts is evaluated by constructing a frequency response of the equivalent human body system. Only two stainless-steel electrodes are employed in the measurement and evaluation.
引用
收藏
页码:1656 / 1660
页数:5
相关论文
共 50 条
  • [31] Measurement of body water by multifrequency bioelectrical impedance spectroscopy in a multiethnic pediatric population
    Ellis, KJ
    Shypailo, RJ
    Wong, WW
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1999, 70 (05): : 847 - 853
  • [32] Techniques used in the measurement of body composition: An overview with emphasis on bioelectrical impedance analysis
    Heymsfield, SB
    Wang, ZM
    Visser, M
    Gallagher, D
    Pierson, RN
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 64 (03): : 478 - 484
  • [33] Correlation between body composition measurement by bioelectrical impedance analysis and intradialytic hypotension
    Zhou, Qin
    Wang, Jiaqi
    Xie, Shuqin
    Yuan, Shiyi
    Zhong, Ling
    Chen, Jianwei
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2020, 52 (05) : 953 - 958
  • [34] Correlation between body composition measurement by bioelectrical impedance analysis and intradialytic hypotension
    Qin Zhou
    Jiaqi Wang
    Shuqin Xie
    Shiyi Yuan
    Ling Zhong
    Jianwei Chen
    International Urology and Nephrology, 2020, 52 : 953 - 958
  • [35] Accuracy augmentation of body composition measurement by bioelectrical impedance analyzer in elderly population
    Fang, Wen-Hui
    Yang, Jie-Ru
    Lin, Chih-Ying
    Hsiao, Po-Jen
    Tu, Ming-Yu
    Chen, Chien-Fu
    Tsai, Dung-Jang
    Su, Wen
    Huang, Guo-Shu
    Chang, Hung
    Su, Sui-Lung
    MEDICINE, 2020, 99 (07)
  • [36] SENSITIVITY OF BIOELECTRICAL IMPEDANCE TO DETECT CHANGES IN HUMAN-BODY COMPOSITION
    ROSS, R
    LEGER, L
    MARTIN, P
    ROY, R
    JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (04) : 1643 - 1648
  • [38] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    不详
    LANCET, 1992, 340 (8834-5): : 1511 - 1511
  • [39] No differences in the body fat after violating core bioelectrical impedance measurement assumptions
    Arshdeep K. Randhawa
    Veronica Jamnik
    Michael D. T. Fung
    Adam S. Fogel
    Jennifer L. Kuk
    BMC Public Health, 21
  • [40] No differences in the body fat after violating core bioelectrical impedance measurement assumptions
    Randhawa, Arshdeep K.
    Jamnik, Veronica
    Fung, Michael D. T.
    Fogel, Adam S.
    Kuk, Jennifer L.
    BMC PUBLIC HEALTH, 2021, 21 (01)