Measurement and Evaluation of the Bioelectrical Impedance of the Human Body by Deconvolution of a Square Wave

被引:3
|
作者
Tseng, Yuhwai [1 ]
Su, Chauchin [2 ]
Liu, Chien-Nan Jimmy [1 ]
机构
[1] Natl Cent Univ, Dept Elect Engn, Jhongli 320, Taiwan
[2] Natl Chiao Tung Univ, Dept Elect & Control Engn, Hsinchu 300, Taiwan
来源
关键词
body impedance; square test waveform; deconvolution;
D O I
10.1587/transinf.E93.D.1656
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this study, we use the deconvolution of a square test stimulus to replace a series of sinusoidal test waveforms with different frequencies to simplify the measurement of human body impedance. The average biological impedance of body parts is evaluated by constructing a frequency response of the equivalent human body system. Only two stainless-steel electrodes are employed in the measurement and evaluation.
引用
收藏
页码:1656 / 1660
页数:5
相关论文
共 50 条
  • [1] The measurement of body composition by bioelectrical impedance
    Popa, Monica
    Sirbu, Dana
    Curseu, Daniela
    Ionutas, Alina
    2006 IEEE-TTTC INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS, VOL 2, PROCEEDINGS, 2006, : 437 - 440
  • [2] Bioelectrical impedance: The effect of exercise on bioelectrical impedance measurement and calculation of body composition
    Civar, S
    Ozer, K
    Gursel, E
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2006, 77 (01) : A37 - A38
  • [3] Bioelectrical impedance analysis in body composition measurement
    不详
    NUTRITION, 1996, 12 (11-12) : 749 - 759
  • [4] BIOELECTRICAL-IMPEDANCE MEASUREMENT OF BODY-WATER
    BOULIER, A
    THOMASSET, AL
    APFELBAUM, M
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1992, 55 (03): : 761 - 762
  • [5] Evaluation Of A Bioelectrical Impedance Device In The Analysis Of Body Composition
    Gogain, Melissa
    Schoffstall, James
    McLaughlin, James
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 317 - 317
  • [6] Evaluation of lymph drainage using bioelectrical impedance of the body
    de Godoy, J. M. P.
    Valente, F. M.
    Azoubel, L. M.
    Godoy, M. F. G.
    PHLEBOLOGY, 2011, 26 (07) : 298 - 300
  • [7] Evaluation Of A Bioelectrical Impedance Device In The Analysis Of Body Composition
    Gogain, Melissa
    Schoffstall, James
    McLaughlin, James
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2012, 27 : 317 - 317
  • [8] MEASUREMENT OF BODY-COMPOSITION USING BIOELECTRICAL IMPEDANCE ANALYSIS
    LUBANSKI, RE
    KURZER, M
    MEGUID, MM
    CLINICAL RESEARCH, 1987, 35 (03): : A775 - A775
  • [9] Bioelectrical parameters of the whole human body obtained through bioelectrical impedance analysis
    Lafargue, AL
    Cabrales, LB
    Larramendi, RM
    BIOELECTROMAGNETICS, 2002, 23 (06) : 450 - 454
  • [10] Bioelectrical impedance - a tool for assessing the composition of the human body
    Carriero, Cosimo
    Electronics World, 2021, 127 (2006): : 22 - 24