Methodology for improved detection of coronary stenoses with computed tomographic angiography

被引:21
|
作者
Budoff, MJ
Lu, B
Shinbane, JS
Chen, L
Child, J
Carson, S
Mao, SS
机构
[1] Harbor UCLA Med Ctr, Dept Med, Div Cardiol, Torrance, CA 90502 USA
[2] St Johns Cardiovasc Res Ctr, Torrance, CA USA
[3] FuWai Hosp, Peking Union Med Coll, Cardiovasc Inst, Dept Radiol, Beijing, Peoples R China
[4] Chinese Acad Sci, Beijing, Peoples R China
[5] XiJing Hosp, Dept Radiol, Xian, Peoples R China
关键词
D O I
10.1016/j.ahj.2004.04.043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Noninvasive angiography is a promising technique for visualization of the coronary lumen; however, current methodologies lead to limited accuracy. We assessed the accuracy of electron beam computed tomographic angiography (EBA) for detection of coronary stenoses, using improved triggering techniques and thinner slice collimation. Methods Eighty-six patients with suspected coronary disease were studied with EBA and conventional invasive coronary angiography. Electrocardiographic triggering was performed at a fixed time in end systole to reduce cardiac motion. Thin (1.5 mm) slices were obtained with 1.5 mm table incrementation. In axial (2-dimensional) EBA images and 3-dimensional reconstructions, all coronary arteries and side branches with a diameter of greater than or equal to1.5 mm were assessed for the presence of stenoses with >50% diameter reduction. Both EBA and invasive angiographic images were assessed in a blinded manner. Results In comparison to invasive coronary angiography, EBA correctly classified 49 of 53 patients (92%) as having at least 1 coronary stenosis. Overall, 103 stenoses with >50% diameter reduction were present, and 93 of these lesions were correctly detected by EBA (sensitivity 90%, specificity 93%, positive predictive value 84%, and negative predictive value 96%). Only 5% of vessels could not be assessed, predominantly due to significant calcification. Conclusions Thinner slice collimation and end-systolic electrocardiographic triggering improves accuracy and assessment of coronary EBA for the detection of obstructive coronary artery disease, making this study clinically useful in the evaluation of obstructive coronary artery disease.
引用
收藏
页码:1085 / 1090
页数:6
相关论文
共 50 条
  • [41] Simultaneous computed tomographic angiography of the coronary and radial arteries
    Tamaoki, Hiroya
    Yoshimachi, Fuminobu
    Sakurai, Tsuyoshi
    Shin, Tomoyasu
    Ikari, Yuji
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2020, 35 (02) : 185 - 193
  • [42] Accuracy of 320 computed tomography coronary angiography in detection of functionally significant stenoses - comparison with FFR
    Ko, Brian
    Cameron, James
    Leung, Michael
    Wong, Dennis
    Leong, Darryl
    Meredith, Ian
    Antonis, Paul
    Malaiapan, Yuvi
    Seneviratne, Sujith
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B68 - B68
  • [43] Computed tomographic angiography of the coronary arteries: Techniques and applications
    Gerber, TC
    Breen, JF
    Kuzo, RS
    Kantor, B
    Williamson, EE
    Safford, RE
    Morin, RL
    SEMINARS IN ULTRASOUND CT AND MRI, 2006, 27 (01) : 42 - 55
  • [44] Diagnostic Accuracy and Impact of Computed Tomographic Coronary Angiography on Utilization of Invasive Coronary Angiography
    Chow, Benjamin J. W.
    Abraham, Arun
    Wells, George A.
    Chen, Li
    Ruddy, Terrence D.
    Yam, Yeung
    Govas, Nayia
    Galbraith, Phoebe Diane
    Dennie, Carole
    Beanlands, Rob S.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (01) : 16 - 23
  • [45] Whole-heart coronary magnetic resonance angiography: Value for the detection of coronary artery stenoses in comparison to multislice computed tomography angiography
    Maintz, D.
    Ozgun, M.
    Hoffmeier, A.
    Quante, M.
    Fischbach, R.
    Manning, W. J.
    Heindel, W.
    Botnar, R. M.
    ACTA RADIOLOGICA, 2007, 48 (09) : 967 - 973
  • [46] Detection of in-stent restenosis by 64 detector computed tomographic coronary angiography: Comparison with quantitative selective coronary angiography.
    Hecht, Harvey S.
    Zaric, Maja
    Jelnin, Vladimir
    Lubarsky, Lev
    Prakash, Manish
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 13B - 13B
  • [47] Automatic centerline extraction of coronary arteries in coronary computed tomographic angiography
    Guanyu Yang
    Pieter Kitslaar
    Michel Frenay
    Alexander Broersen
    Mark J. Boogers
    Jeroen J. Bax
    Johan H. C. Reiber
    Jouke Dijkstra
    The International Journal of Cardiovascular Imaging, 2012, 28 : 921 - 933
  • [48] Application of Quantitative Assessment of Coronary Atherosclerosis by Coronary Computed Tomographic Angiography
    Lee, Su Nam
    Lin, Andrew
    Dey, Damini
    Berman, Daniel S.
    Han, Donghee
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (06) : 518 - 539
  • [49] Automatic centerline extraction of coronary arteries in coronary computed tomographic angiography
    Yang, Guanyu
    Kitslaar, Pieter
    Frenay, Michel
    Broersen, Alexander
    Boogers, Mark J.
    Bax, Jeroen J.
    Reiber, Johan H. C.
    Dijkstra, Jouke
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04): : 921 - 933
  • [50] Stent Sizing by Coronary Computed Tomographic Angiography: Comparison With Conventional Coronary Angiography in an Experienced Setting
    de Silva, Ramesh
    Mussap, Christian J.
    Hecht, Harvey S.
    van Mieghem, Nicolas M.
    Matarazzo, Thomas J.
    Roubin, Gary S.
    Panagopoulos, Georgia
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (05) : 755 - 763