Detection of Glucose Using Non-Invasive Method and Food Analysis for Diabetic Patients Using IoT

被引:0
|
作者
Suriya, N. [1 ]
Pavithra, S. [2 ]
Solomon, K. Santhosh [1 ]
Reddy, Yaswanth [1 ]
机构
[1] Chennai Inst Technol, Dept ECE, Chennai 600069, Tamil Nadu, India
[2] Chennai Inst Technol, Dept CSE, Chennai 600069, Tamil Nadu, India
来源
关键词
DIABETES; GLUCOMETER; HEALTH MONITORING; WEARABLE SENSORS; MOBILE APPLICATION;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In current trends of smart wearables, there are lot of smart devices for healthcare systems. Among them the detection of Glucose from the patient is tested using blood sample by pricking the finger. This paper demonstrates a device to test the blood glucose level using non-invasive method of not pricking the finger. A Node MCU 32S is used as microcontroller to obtain the readings from the blood glucose detector, temperature sensor and heart rate sensor. The Glucose detector contains PIC16LF178X chip and has two electrodes to send and receive data bits. The electrodes are placed on the tongue where one electrode sends a certain bit of data. The data bits when passed through the blood in the tongue, certain amount is lost due to the presence of glucose. The remaining bits are detected at the second electrode. The difference between these values gives the amount of glucose in the blood. The temperature sensor detects body temperature. The pulse sensor detects the heart rate and blood pressure. These readings are displayed on the mobile application which is connected to the microcontroller via interne. Based on these readings, the microcontroller sends alerts in the mobile application. The dietary suggestions are given to the patient through the mobile application in order to maintain normal glucose levels and also to reduce in times of high glucose levels. A list of foods which should be taken is displayed on the mobile application
引用
收藏
页码:167 / 171
页数:5
相关论文
共 50 条
  • [21] Analysis of the effective signal extraction method in near infrared non-invasive blood glucose detection
    Liu, H. M.
    Lin, J.
    Liu, Y. J.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 123 : 73 - 73
  • [22] Non-enzymatic and non-invasive glucose detection using Au nanoparticle decorated CuO nanorods
    Chakraborty, Pinak
    Dhar, Saurab
    Debnath, Kamalesh
    Majumder, Tanmoy
    Mondal, Suvra Prakash
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 283 : 776 - 785
  • [23] Non-invasive detection of glucose in porcine eyes
    Ergin, A
    Thomas, GA
    2005 IEEE 31ST ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2005, : 246 - 247
  • [24] Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors
    Heinemann, L
    Schmelzeisen-Redeker, G
    DIABETOLOGIA, 1998, 41 (07) : 848 - 854
  • [25] Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors
    L. Heinemann
    G. Schmelzeisen-Redeker
    Diabetologia, 1998, 41 : 848 - 854
  • [26] Non-invasive Blood Glucose Measurement Using Transmission Spectroscopy
    Khawam, Yahya
    Ali, Muddassar
    Shazada, Haris
    Kanan, Sofian
    Nashash, Hasan
    2013 FIRST INTERNATIONAL CONFERENCE ON COMMUNICATIONS SIGNAL PROCESSING, AND THEIR APPLICATIONS (ICCSPA'13), 2013,
  • [27] Non-invasive monitoring of blood glucose using Raman spectroscopy
    Peterson, CM
    Peterson, KP
    Chaiken, J
    Finney, W
    Knudson, PE
    Weinstock, RS
    DIABETES, 2000, 49 : A121 - A121
  • [28] Non-Invasive Glucose Monitoring Using Open Electromagnetic Waveguides
    Hofmann, M.
    Bloss, M.
    Weigel, R.
    Fischer, G.
    Kissinger, D.
    2012 42ND EUROPEAN MICROWAVE CONFERENCE (EUMC), 2012, : 546 - 549
  • [29] Non-Invasive Blood Glucose Monitoring using a Hybrid Technique
    Nanayakkara, Nuwan D.
    Munasingha, S. C.
    Ruwanpathirana, G. P.
    2018 MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON) 4TH INTERNATIONAL MULTIDISCIPLINARY ENGINEERING RESEARCH CONFERENCE, 2018, : 7 - 12
  • [30] A Survey on Non-Invasive Blood Glucose Monitoring Using NIR
    Menon, K. A. Unnikrishna
    Hemachandran, Deepak
    Abhishek, T. K.
    2013 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND SIGNAL PROCESSING (ICCSP), 2013, : 1069 - 1072