Noninvasive intracranial compliance monitoring - Technical note and clinical results

被引:27
|
作者
Lang, EW
Paulat, K
Witte, C
Zolondz, J
Mehdorn, HM
机构
[1] Univ Kiel, Dept Neurosurg, Kiel, Germany
[2] Univ Appl Sci, Dept Med Cybernet, Fachhochsch Ulm, Germany
[3] DWL Inc, Sipplingen, Germany
关键词
intracranial compliance; intracranial pressure monitoring; waveform analysis;
D O I
10.3171/jns.2003.98.1.0214
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Although invasive measurement of intracranial pressure (ICP) involving high-resolution waveform analysis allows assessment of intracranial compliance (ICC), it is only feasible in a few selected neurosurgical conditions. Intracranial compliance can be assessed using the high-frequency centroid (HFC), which is the power-weighted mean frequency within the 4 to 15-Hz band of the ICP waveform. The authors have systematically tested the utility, performance, and reliability of a noninvasive monitor of ICC. The underlying principle of this device is that the ICP transmission and its infrasonic waves are transmitted through the inner ear toward the tympanic membrane. If the outer ear is sealed in an airtight fashion, motions of the tympanic membrane cause air pressure fluctuations that can be recorded using a special sensor. The authors compared the HFC calculated from an intraparenchymal ICP sensor with that obtained simultaneously from an ipsilaterally placed noninvasive device during half of a respiratory cycle (peak to baseline) as well as for three random samples of three heart cycles. They analyzed 32 sessions in 13 patients in whom mechanical ventilation had been established. In four (11%) of 36 sessions they could not demonstrate an adequate signal. For the peak-to-baseline cycle, the mean invasively recorded HFC was 8.05 +/- 0.55 Hz (range 6.7-9 Hz) whereas the mean noninvasively recorded HFC was 8.04 +/- 0.49 Hz (range 7-9.3 Hz). The ICP was 8.5 +/- 5 mm Hg (range 2-24 mm Hg). For the three heart cycles randomly sampled, the values were 7.73 +/- 0.51 Hz (range 6.7-8.6 Hz) and 7.76 +/- 0.56 mm Hg (range 6.5-8.8 mm Hg), respectively. This device allows noninvasive assessment of ICC based on the HFC waveform analysis that is equivalent to that obtained by invasive intraparenchymal recording. The monitoring device may become a valuable tool for monitoring parameters in patients in whom placement of an intracranial sensor is not feasible but assessment of ICC as an alternative to ICP measurement is desired.
引用
收藏
页码:214 / 218
页数:5
相关论文
共 50 条
  • [21] Noninvasive assessment of intracranial pressure waveforms by using pulsed phase lock loop technology - Technical note
    Ueno, T
    Macias, BR
    Yost, WT
    Hargens, AR
    JOURNAL OF NEUROSURGERY, 2005, 103 (02) : 361 - 367
  • [23] Review: pathophysiology of intracranial hypertension and noninvasive intracranial pressure monitoring
    Canac, Nicolas
    Jalaleddini, Kian
    Thorpe, Samuel G.
    Thibeault, Corey M.
    Hamilton, Robert B.
    FLUIDS AND BARRIERS OF THE CNS, 2020, 17 (01)
  • [24] Review: pathophysiology of intracranial hypertension and noninvasive intracranial pressure monitoring
    Nicolas Canac
    Kian Jalaleddini
    Samuel G. Thorpe
    Corey M. Thibeault
    Robert B. Hamilton
    Fluids and Barriers of the CNS, 17
  • [25] MINIATURIZED METHODS TO MONITOR INTRACRANIAL-PRESSURE - TECHNICAL AND CLINICAL RESULTS
    GAAB, M
    KNOBLICH, OE
    DIETRICH, K
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1979, 350 (01): : 13 - 31
  • [26] Validation of a Noninvasive Approach for Cerebrospinal Compliance Monitoring
    Brasil, Sergio
    Ben-Hur, Igor
    Cardim, Danilo
    Czosnyka, Marek
    Paiva, Wellingson S.
    Frigieri, Gustavo
    NEUROCRITICAL CARE, 2025,
  • [27] Noninvasive intracranial pressure monitoring in women with migraine
    Rossi, Denise Martineli
    Bevilaqua-Grossi, Debora
    Mascarenhas, Sergio
    Dutra de Souza, Hugo Celso
    Carvalho, Gabriela Ferreira
    Carmona Vendramim, Ana Carolina
    Philbois, Stella Vieira
    Dach, Fabiola
    Tallarico, Francisco Jose
    de Oliveira, Anamaria Siriani
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [28] Noninvasive intracranial pressure monitoring in women with migraine
    Denise Martineli Rossi
    Débora Bevilaqua-Grossi
    Sérgio Mascarenhas
    Hugo Celso Dutra de Souza
    Gabriela Ferreira Carvalho
    Ana Carolina Carmona Vendramim
    Stella Vieira Philbois
    Fabíola Dach
    Francisco José Tallarico
    Anamaria Siriani de Oliveira
    Scientific Reports, 12
  • [29] CAROTID CONTROL FOR INTRACRANIAL ANEURYSMS - TECHNICAL NOTE
    HEIFETZ, MD
    JOURNAL OF NEUROSURGERY, 1988, 69 (01) : 142 - 142
  • [30] Noninvasive Intracranial Pressure Monitoring: Are We There Yet?
    Rajajee, Venkatakrishna
    NEUROCRITICAL CARE, 2024, 41 (2) : 332 - 338