An in vitro verification of strength estimation for moving an 125I source during implantation in brachytherapy

被引:3
|
作者
Tanaka, Kenichi [1 ]
Kajimoto, Tsuyoshi [1 ]
Hayashi, Takahiro [1 ]
Asanuma, Osamu [2 ]
Hori, Masakazu [3 ]
Kamo, Ken-ichi [3 ]
Sumida, Iori [4 ]
Takahashi, Yutaka [4 ]
Tateoka, Kunihiko [3 ]
Bengua, Gerard [5 ]
Sakata, Koh-ichi [3 ]
Endo, Satoru [1 ]
机构
[1] Hiroshima Univ, Grad Sch Engn, Quantum Energy Applicat, 1-4-1 Kagamiyama, Higashihiroshima, Hiroshima 7398527, Japan
[2] Sapporo Med Univ Hosp, Div Radiol & Nucl Med, Chuo Ward, South 1,West 17, Sapporo, Hokkaido 0608556, Japan
[3] Sapporo Med Univ, Grad Sch Med, Dept Radiat Oncol, Chuo Ward, South 1,West 16, Sapporo, Hokkaido 0608543, Japan
[4] Osaka Univ, Grad Sch Med, Dept Radiol, 2-2 Yamada Oka, Suita, Osaka 5650871, Japan
[5] Auckland City Hosp, Pk Rd, Auckland 1142, New Zealand
基金
日本学术振兴会; 日本科学技术振兴机构;
关键词
brachytherapy; I-125; source strength; moving source; verification; INTERSTITIAL BRACHYTHERAPY; DOSIMETRY;
D O I
10.1093/jrr/rry021
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aims to demonstrate the feasibility of a method for estimating the strength of a moving brachytherapy source during implantation in a patient. Experiments were performed under the same conditions as in the actual treatment, except for one point that the source was not implanted into a patient. The brachytherapy source selected for this study was I-125 with an air kerma strength of 0.332 U (mu Gym(2)h(-1)), and the detector used was a plastic scintillator with dimensions of 10 cm x 5 cm x 5 cm. A calibration factor to convert the counting rate of the detector to the source strength was measured and then the accuracy of the proposed method was investigated for a manually driven source. The accuracy was found to be under 10% when the shielding effect of additional needles for implantation at other positions was corrected, and about 30% when the shielding was not corrected. Even without shielding correction, the proposed method can detect dead/dropped source, implantation of a source with the wrong strength, and a mistake in the number of the sources implanted. Furthermore, when the correction was applied, the achieved accuracy came close to within 7% required to find the Oncoseed 6711 (I-125 seed with unintended strength among the commercially supplied values of 0.392, 0.462 and 0.533 U).
引用
收藏
页码:484 / 489
页数:6
相关论文
共 50 条
  • [41] 125I plaque brachytherapy for anterior uveal melanomas
    L Lumbroso-Le Rouic
    M Charif Chefchaouni
    C Levy
    C Plancher
    R Dendale
    B Asselain
    S Solignac
    A Mazal
    L Desjardins
    Eye, 2004, 18 : 911 - 916
  • [42] 125I plaque brachytherapy for anterior uveal melanomas
    Lumbroso-Le Rouic, L
    Chefchaouni, MC
    Levy, C
    Plancher, C
    Dendale, R
    Asselain, B
    Solignac, S
    Mazal, A
    Desjardins, L
    EYE, 2004, 18 (09) : 911 - 916
  • [43] Patient release during brain brachytherapy with a temporarily-afterloaded high activity, liquid 125I source.
    Deguzman, A
    Shaw, E
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 317P - 317P
  • [44] A Monte Carlo evaluation of the dosimetric characteristics of the Best® model 2301 125I brachytherapy source
    Sowards, KT
    Meigooni, AS
    APPLIED RADIATION AND ISOTOPES, 2002, 57 (03) : 327 - 333
  • [45] Determination of dose calculation parameters of 125I brachytherapy source with Monte-Carlo method
    Department of Engineering Physics, Tsinghua University, Beijing 100084, China
    Yuanzineng Kexue Jishu, 2006, 6 (657-661):
  • [46] Experimental Verification of Dosimetric Parameters for a New I-125 Interstitial Brachytherapy Source
    Kennedy, R.
    Davis, S.
    Micka, J.
    MEDICAL PHYSICS, 2009, 36 (06) : 2533 - +
  • [47] The safety and efficacy of interstitial 125I seed implantation brachytherapy for metastatic epidural spinal cord compression
    Lu, Jian
    Huang, Wei
    Wang, Zhongmin
    Gong, Ju
    Ding, Xiaoyi
    Chen, Zhijin
    Xia, Ning
    Yang, Nannan
    Wu, Zhiyuan
    Wang, Chen
    Chen, Jun
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2018, 14 (07) : 1549 - 1555
  • [48] 125I Brachytherapy Seeds Implantation for Inoperable Low-Grade Leiomyosarcoma of Inferior Vena Cava
    Li, Yuliang
    Wang, Yongzheng
    Liu, Bin
    Li, Zheng
    Wang, Wujie
    KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (02) : 278 - 282
  • [49] THE ANALYSIS OF SIGNIFICANT FACTORS OF DEVELOPMENT OF EDEMA DURING PERMANENT BRACHYTHERAPY WITH MICROSOURCES 125I
    Panarina, N.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S404 - S404
  • [50] Treatment planning considerations for 125I eye plaque brachytherapy
    Miguel, David
    Maria de Frutos, Jesus
    Lopez-Lora, Francisco
    Alonso, Pilar
    Diezhandino, Patricia
    Antonia Saornil, Maria
    Garcia, Ciro
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (03) : 280 - 284