Defining the Clinical Role of Swept-Source Anterior Segment Optical Coherence Tomography in Eyes Undergoing Strabismus Surgery

被引:2
|
作者
Pujari, Amar [1 ]
Patil, Vinay [1 ]
Chauhan, Nidhi [1 ]
Thangavel, Rajeswari [1 ]
Phuljhele, Swati [1 ]
Saxena, Rohit [1 ]
机构
[1] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, Room 212,RPC-1, New Delhi, India
来源
CLINICAL OPHTHALMOLOGY | 2022年 / 16卷
关键词
swept source anterior segment imaging; extraocular muscle imaging; imaging in strabismus; ASOCT imaging of extraocular muscles; EXTRAOCULAR-MUSCLES; INSERTION; ACCURACY;
D O I
10.2147/OPTH.S365622
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the clinical role of swept-source anterior segment optical coherence tomography in extraocular muscle imaging in various strabismic conditions. Study Design: Prospective observational study. Participants: A total of 1104 extraocular muscles of 150 subjects were imaged. Normal eyes (640 muscles), eyes undergoing reoperation (240 muscles), paralytic strabismic eyes (16 muscles), non-paralytic strabismic eyes (20 muscles), post-traumatic strabismic eyes (64 muscles), eyes with thyroid disease (64 muscles), and other atypical cases (60 muscles) were imaged. In all cases, up to four recti muscles were evaluated in a given eye depending on the need. Results: The mean age was 38.15 +/- 16.25 years. Overall, muscle insertion was identified in over 90% of the subjects. Apart from normal muscles (n = 860, 93.68%), the location was identified in previously operated eyes (n = 54, 90%), in traumatic muscle slippage (n = 2, 11.11%), in ocular coat ectasia (n = 11, 91.66%), in thyroid muscle hypertrophy, in operated scleral fixated intraocular lens with strabismus, and other challenging cases. In all circumstances, clinically useful information was obtained from the anterior 4-14 millimetres of the rectus muscle, which in turn helped in active surgical planning and overall management. Conclusion: The SS-ASOCT with its wider and deeper scanning abilities was able to locate the extraocular muscle insertion in a variety of strabismic conditions. Therefore, this tool can be used in the preoperative periods for optimal surgical planning and management.
引用
收藏
页码:1449 / 1465
页数:17
相关论文
共 50 条
  • [31] Objective quantification of lens nuclear opacities using swept-source anterior segment optical coherence tomography
    Wang, Wei
    Zhang, Jiaqing
    Gu, Xiaoxun
    Ruan, Xiaoting
    Chen, Xiaoyun
    Tan, Xuhua
    Jin, Guangming
    Wang, Lanhua
    He, Mingguang
    Congdon, Nathan
    Liu, Zhenzhen
    Luo, Lixia
    Liu, Yizhi
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (06) : 790 - 794
  • [32] Corneal thickness mapping by 3D swept-source anterior segment optical coherence tomography
    Neri, Alberto
    Malori, Marianna
    Scaroni, Patrizia
    Leaci, Rosachiara
    Delfini, Elisabetta
    Macaluso, Claudio
    ACTA OPHTHALMOLOGICA, 2012, 90 (06) : e452 - e457
  • [33] Diagnostic criteria of anterior segment swept-source optical coherence tomography to detect gonioscopic angle closure
    Guo, Philip Yawen
    Zhang, Xiulan
    Li, Fei
    Lin, Chen
    Nguyen, Anwell
    Sakata, Rei
    Higashita, Risa
    Okamoto, Keiichiro
    Yu, Marco
    Aihara, Makoto
    Aung, Tin
    Lin, Shan
    Leung, Christopher Kai-Shun
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024, 108 (08) : 1130 - 1136
  • [34] Implantable Collamer Lens Sizing Method Based on Swept-Source Anterior Segment Optical Coherence Tomography
    Nakamura, Tomoaki
    Isogai, Naoki
    Kojima, Takashi
    Yoshida, Yoko
    Sugiyama, Yasuo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 187 : 99 - 107
  • [35] Evaluation of lymphatic vessel dilatations by anterior segment swept-source optical coherence tomography: case report
    Eva Volek
    Jeannette Toth
    Zoltan Zsolt Nagy
    Miklos Schneider
    BMC Ophthalmology, 17
  • [36] Observation of anterior chamber volume after cataract surgery with swept-source optical coherence tomography
    Chen, Minjie
    Hu, Hailin
    He, Wenwen
    Lu, Yi
    Zhu, Xiangjia
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (08) : 1837 - 1844
  • [37] Optimization of implantable collamer lens sizing based on swept-source anterior segment optical coherence tomography
    Nakamura, Tomoaki
    Isogai, Naoki
    Kojima, Takashi
    Yoshida, Yoko
    Sugiyama, Yasuo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (05): : 742 - 748
  • [38] Screening for Subclinical Keratoconus Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography
    Steinberg, Johannes
    Casagrande, Maria K.
    Frings, Andreas
    Katz, Toam
    Druchkiv, Vasyl
    Richard, Gisbert
    Linke, Stephan J.
    CORNEA, 2015, 34 (11) : 1413 - 1419
  • [39] Observation of anterior chamber volume after cataract surgery with swept-source optical coherence tomography
    Minjie Chen
    Hailin Hu
    Wenwen He
    Yi Lu
    Xiangjia Zhu
    International Ophthalmology, 2019, 39 : 1837 - 1844
  • [40] OcularBiometric Characteristics Measured by Swept-Source Optical Coherence Tomography in Individuals Undergoing Cataract Surgery
    Wasser, Lauren M.
    Tsessler, Maria
    Weill, Yishay
    Zadok, David
    Abulafia, Adi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 233 : 38 - 47