Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands

被引:12
|
作者
Morvannou, Ania [1 ,3 ]
Troesch, Stephane [1 ]
Esser, Dirk [2 ]
Forquet, Nicolas [3 ]
Petitjean, Alain [1 ]
Molle, Pascal [3 ]
机构
[1] Epur Nat, 12 Rue Toussaint Flechaire, F-84510 Caumont Sur Durance, France
[2] Soc Ingn Nat & Tech, F-73370 Chef Lieu, La Chapelle Du, France
[3] Irstea, Wastewater Treatment Team, Freshwater Syst Ecol & Pollut Res Unit, 5 Rue Doua,CS 70077, F-69626 Villeurbanne, France
关键词
footprint; performance; unsaturated/saturated conditions; vertical flow constructed wetland; SINGLE-STAGE; TREATMENT PERFORMANCES; RECIRCULATION; SEWAGE;
D O I
10.2166/wst.2017.115
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
French vertical flow constructed wetlands (VFCW) treating raw wastewater have been developed successfully over the last 30 years. Nevertheless, the two-stage VFCWs require a total filtration area of 2-2.5 m(2)/P.E. Therefore, implementing a one-stage system in which treatment performances reach standard requirements is of interest. Biho-Filter (R) is one of the solutions developed in France by Epur Nature. Biho-Filter (R) is a vertical flow system with an unsaturated layer at the top and a saturated layer at the bottom. The aim of this study was to assess this new configuration and to optimize its design and operating conditions. The hydraulic functioning and pollutant removal efficiency of three different Biho-Filter (R) plants commissioned between 2011 and 2012 were studied. Outlet concentrations of the most efficient Biho-Filter (R) configuration are 70 mg/L, 15 mg/L, 15 mg/L and 25 mg/L for chemical oxygen demand (COD), 5-day biological oxygen demand (BOD5), total suspended solids (TSS) and total Kjeldahl nitrogen (TKN), respectively. Up to 60% of total nitrogen is removed. Nitrification efficiency is mainly influenced by the height of the unsaturated zone and the recirculation rate. The optimum recirculation rate was found to be 100%. Denitrification in the saturated zone works at best with an influent COD/NO3-N ratio at the inflet of this zone larger than 2 and a hydraulic retention time longer than 0.75 days.
引用
收藏
页码:124 / 133
页数:10
相关论文
共 50 条
  • [1] Effects of partially saturated conditions on the metabolically active microbiome and on nitrogen removal in vertical subsurface flow constructed wetlands
    Pelissari, Catiane
    Guivernau, Miriam
    Vinas, Marc
    Garcia, Joan
    Velasco-Galilea, Maria
    Souza, Samara Silva
    Sezerino, Pablo Heleno
    Avila, Cristina
    WATER RESEARCH, 2018, 141 : 185 - 195
  • [2] A partial siphon operational strategy strengthens nitrogen removal performance in partially saturated vertical flow constructed wetlands
    Zuo S.
    Wang Y.
    Wu J.
    Zhong F.
    Kong L.
    Chen Y.
    Cheng S.
    Chemosphere, 2024, 361
  • [3] Simultaneous removal of vanadium and nitrogen in two-stage vertical flow constructed wetlands: Performance and mechanisms
    Chi, Zifang
    Li, Wenjing
    Zhang, Pengdong
    Li, Huai
    Chemosphere, 2024, 367
  • [4] The improvement of pollutant removal efficiency in saturated vertical flow constructed wetlands by tubifex tubifex
    Yang, Jiqiang
    Li, Qiming
    An, Yu
    Zhang, Miao
    Du, Juan
    Chen, Chen
    Zhao, Ran
    Zhao, Dehua
    An, Shuqing
    BIORESOURCE TECHNOLOGY, 2020, 318
  • [5] Toxicity of Chromium on Nitrogen and Biodegradable Compound Removal in Vertical Flow Constructed Wetlands
    Basnayaka, H. A.
    Koottatep, T.
    ENGINEER-JOURNAL OF THE INSTITUTION OF ENGINEERS SRI LANKA, 2009, 42 (02): : 40 - 46
  • [6] Modeling of Organic Substances and Ammonia Nitrogen Removal in Vertical Flow Constructed Wetlands
    Malinowski, Pawel
    Dabrowski, Wojciech
    JOURNAL OF ECOLOGICAL ENGINEERING, 2020, 21 (01): : 231 - 237
  • [7] Nitrogen removal in vertical flow constructed wetlands: The influence of recirculation and partial saturation
    Baggiotto, Carine
    Decezaro, Samara Terezinha
    Lutterbeck, Carlos Alexandre
    Friedrich, Marciano
    Ramirez, Rolando Jose Manuel Gonzalez
    Wolff, Delmira Beatriz
    ECOLOGICAL ENGINEERING, 2025, 212
  • [8] Removal of bacterial and viral indicators in vertical flow constructed wetlands and intermittent sand filters
    Torrens, Antonina
    Molle, Pascal
    Boutin, Catherine
    Salgot, Miquel
    DESALINATION, 2009, 246 (1-3) : 169 - 178
  • [9] Effects of chromate on nitrogen removal and microbial community in two-stage vertical-flow constructed wetlands
    Chi Z.
    Zhang P.
    Hou L.
    Li H.
    Liang S.
    Song A.
    Chemosphere, 2023, 345
  • [10] Nitrogen removal in vertical flow constructed wetlands: influence of bed depth and high nitrogen loadings
    Almeida, Adelaide
    Jozwiakowski, Krzysztof
    Kowalczyk-Jusko, Alina
    Bugajski, Piotr
    Kurek, Karolina
    Carvalho, Fatima
    Durao, Anabela
    Ribeiro, Carlos
    Gajewska, Magdalena
    ENVIRONMENTAL TECHNOLOGY, 2020, 41 (17) : 2196 - 2209