Co-extracted electrons and beam inhomogeneity in the large negative ion source SPIDER

被引:13
|
作者
Pimazzoni, Antonio [1 ,2 ]
Agostini, Matteo [2 ]
Brombin, Matteo [2 ]
Marconato, Nicolo [2 ,3 ]
Sartori, Emanuele [2 ]
Pasqualotto, Roberto [2 ]
Serianni, Gianluigi [2 ]
机构
[1] Viale Univ 2, INFNLNL, I-35020 Legnaro, Italy
[2] Consorzio RFX, Corso Stati Uniti 4, I-35127 Padua, Italy
[3] Univ Padua, Dipartimento Ingn Ind DII, I-35131 Padua, Italy
关键词
Electrons; Negative ions; SPIDER; Magnetic field; Beam inhomogeneity;
D O I
10.1016/j.fusengdes.2021.112440
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The SPIDER ion source has been designed to generate a current of H- ions up to 60 A and accelerate them up to 100 keV. In addition, the ratio between the co-extracted electrons and negative ions has to be below 1, and a beam inhomogeneity within 10 % has to be attained. A magnetic filter field is produced by a current flowing through the plasma electrode in the vertical direction with the aim of reducing electron temperature and density in the extraction region, so as to enhance the survival probability of H- ions while reducing the co-extracted electrons. Another strategy to reduce the co-extracted electrons is to apply a small bias voltage to the plasma grid with respect to the ion source body. In addition to this, a so-called bias plate is installed in the vicinity of the plasma grid, which can also be biased with respect to source body. However, the application of a bias voltage affects the beam inhomogeneity by modifying the ExB plasma drift within the ion source. Recently, the filter field configuration of SPIDER was modified so as to improve the plasma diffusion towards the extraction region. In addition, the voltage ratings of the bias power supplies were increased. Both these modifications permit to efficiently lower the electron co-extracted current. The present contribution describes such improvements while focusing on the effects they have on the beam inhomogeneity.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Improvement of extracted ion beam from cold cathode Penning ion source
    Radwan, Samah I.
    El-Khabeary, H.
    Helal, A. G.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 144 : 351 - 355
  • [42] Manufacturing of the full size prototype of the ion source for the ITER neutral beam injector - The SPIDER beam source
    Pavei, Mauro
    Boilson, Deirdre
    Bonicelli, Tullio
    Boury, Jacques
    Bush, Michael
    Ceracchi, Andrea
    Faso, Diego
    Graceffa, Joseph
    Heinemann, Bernd
    Hemsworth, Ronald
    Lievin, Christophe
    Marcuzzi, Diego
    Masiello, Antonio
    Sczepaniak, Bernd
    Singh, Mahendrajit
    Toigo, Vanni
    Zaccaria, Pierluigi
    FUSION ENGINEERING AND DESIGN, 2015, 96-97 : 319 - 324
  • [44] Technique for the removal of electrons from an extracted, pulsed, H- ion beam
    Perkins, LT
    Herz, PR
    Leung, KN
    Pickard, DS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (10): : 3497 - 3500
  • [45] Study of Negative Ion Beamlets Produced in SPIDER by Beam Emission Spectroscopy
    Agnello, Riccardo
    Barbisan, M.
    Casati, G.
    Pasqualotto, R.
    Serianni, G.
    Zaniol, B.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2022, 50 (11) : 3865 - 3870
  • [46] Separation of beam and electrons in the spallation neutron source H-ion source
    Whealton, JH
    Raridon, RJ
    Leung, KN
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS / PRODUCTION AND APPLICATION OF LIGHT NEGATIVE IONS, 1998, 439 : 244 - 253
  • [47] Design of a visible tomography diagnostic for negative ion RF source SPIDER
    Pasqualotto, R.
    Agostini, M.
    Brombin, M.
    Delogu, R. S.
    Fonnesu, N.
    Lotto, L.
    Molon, F.
    Piron, C.
    Serianni, G.
    Taliercio, C.
    Tollin, M.
    Zaniol, B.
    FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 1253 - 1256
  • [48] Lifetime assessment of the modified grounded grid in the negative ion source SPIDER
    Tomsic, P.
    Berton, G.
    Zaccaria, P.
    Agostinetti, P.
    Pavei, M.
    Marcuzzi, D.
    FUSION ENGINEERING AND DESIGN, 2023, 195
  • [49] Numerical and experimental investigations of a microwave interferometer for the negative ion source SPIDER
    Agnello, R.
    Cavazzana, R.
    Furno, I.
    Jacquier, R.
    Pasqualotto, R.
    Sartori, E.
    Serianni, G.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (03)
  • [50] First measurements of optical emission spectroscopy on SPIDER negative ion source
    Zaniol, Barbara
    Barbisan, Marco
    Bruno, Domenico
    Pasqualotto, Roberto
    Taliercio, Cesare
    Ugoletti, Margherita
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (01):