Improvement of signal-to-noise ratio of electropherograms and analysis reproducibility with digital signal processing and multiple injections

被引:0
|
作者
Kuldvee, R
Kaljurand, M
Smit, HC
机构
[1] Inst Chem, EE-0026 Tallinn, Estonia
[2] Univ Amsterdam, Analyt Chem Lab, NL-1018 WV Amsterdam, Netherlands
来源
关键词
CZE; detection limit; signal-to-noise ratio; correlation chromatography; reproducibility;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poor signal-to-noise ratios and analytical reproducibility in capillary electrophoresis were improved by application of multiple injections of the same sample at (pseudo) randomly chosen time moments. One order of signal-to-noise ratio improvement was achieved in practice using an in-house developed computer-controlled pneumatic sampler. However, it is demonstrated here that better implementation of the capabilities of multiple input requires that the detector signal noise be "pre-whitened", i.e. spikes, baseline drift, oscillations etc, must be removed from the detector signal before transforming it to the electropherogram in the common form. Such filtering of the detector signal was realized by implementing iterative, menu-driven software written in Matlab, a high-level programming language.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 50 条
  • [31] SIGNAL-TO-NOISE RATIO MONITORING CIRCUIT FOR DIGITAL CHANNELS
    KISORZHEVSKIY, VF
    TELECOMMUNICATIONS AND RADIO ENGINEERING, 1974, 28 (03) : 45 - 47
  • [32] SIGNAL-TO-NOISE RATIO ENHANCEMENT THROUGH DOPPLER PROCESSING
    NEWHOUSE, VL
    AMIR, I
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (01): : 119 - 119
  • [33] Measurement of Signal-to-Noise Ratio and Signal-to-Noise and Distortion Ratio Using Histogram Test in Time Domain Analysis
    Jain, Manish
    Sharma, Prakash Chandra
    Tiwari, Pradeep Kumar
    Gupta, Rohit Kumar
    SMART SYSTEMS: INNOVATIONS IN COMPUTING (SSIC 2021), 2022, 235 : 403 - 410
  • [34] Analysis of signal-to-noise ratio in optical receivers
    Bielecki, Z
    Kolosowski, W
    Sedek, E
    Borejko, M
    TELSIKS 2003: 6TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS IN MODERN SATELLITE, CABLE AND BROADCASTING SERVICE, VOLS 1 AND 2, PROCEEDINGS OF PAPERS, 2003, : 71 - 74
  • [35] SIGNAL-PROCESSING STRATEGIES FOR ENHANCEMENT OF SIGNAL-TO-NOISE RATIO OF THERMODILUTION MEASUREMENTS
    JOHNSON, RW
    NORMANN, RA
    ANNALS OF BIOMEDICAL ENGINEERING, 1988, 16 (03) : 265 - 278
  • [36] Improvement of signal-to-interference ratio and signal-to-noise ratio in nerve cuff electrode systems
    Chu, Jun-Uk
    Song, Kang-Il
    Han, Sungmin
    Lee, Soo Hyun
    Kim, Jinseok
    Kang, Ji Yoon
    Hwang, Dosik
    Suh, Jun-Kyo Francis
    Choi, Kuiwon
    Youn, Inchan
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (06) : 943 - 967
  • [37] Analysis of Responsivity and Signal-to-Noise Ratio in PEPT
    Zhou Quan
    Guo Shu-Xu
    Li Zhao-Han
    Song Jing-Yi
    Chang Yu-Chun
    CHINESE PHYSICS LETTERS, 2012, 29 (11)
  • [38] Analysis of signal-to-noise ratio in optical receivers
    Bielecki, Z
    Kolosowski, W
    Sedek, E
    Borejko, M
    ELECTRICAL ENGINEERING AND ELECTROMAGNETICS VI, 2003, 5 : 255 - 264
  • [39] An analysis of the signal-to-noise ratio of a current amplifier
    Brovchenko, VG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2000, 43 (01) : 57 - 62
  • [40] AMBER performances: signal-to-noise ratio analysis
    Malbet, F
    Chelli, A
    Petrov, R
    INTERFEROMETRY IN OPTICAL ASTRONOMY, PTS 1 AND 2, 2000, 4006 : 233 - 242