Three-tesla cardiac magnetic resonance imaging for preterm infants

被引:12
|
作者
Foran, Adrienne M.
Fitzpatrick, Julie A.
Allsop, Joanna
Schmitz, Stephan
Franklin, Jamie
Pamboucas, Constandinos
O'Regan, Declan
Hajnal, Jo V.
Edwards, A. David
机构
[1] Imperial Coll, Dept Paediat, London, England
[2] Imperial Coll, Dept Imaging Sci, London, England
[3] Hammersmith Hosp, MRC, Clin Sci Ctr, London, England
基金
英国医学研究理事会;
关键词
cardiac magnetic resonance imaging; area-length ejection fraction; Sergeant's discs; preterm; newborn; patent ductus arteriosus; left ventricular function;
D O I
10.1542/peds.2006-3305
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
OBJECTIVES. We aimed to establish the feasibility of acquiring 3.0-T cardiac MRIs without sedation, anesthesia, or breath-holding for preterm infants and to obtain preliminary quantitative data on left ventricular function in this population. METHODS. Twelve preterm infants underwent 3.0-T cardiac MRI without sedation or breath-holding. The median gestational age was 29 weeks (range: 26-33 weeks), the median birth weight was 1240 g (range: 808-2200 g), and the median postconceptional age at the time of cardiac MRI was 33 weeks (range: 31-40 weeks). Anatomic images were acquired with T2-weighted spin-echo sequences, and ventricular function was assessed with balanced steady-state free precession cine sequences. We assessed left ventricular function by using the area-length ejection fraction method on horizontal long-axis images and the volumetric Sergeant's discs method of analysis on short-axis images. RESULTS. Imaging was successful for 10 of 12 infants. For those 10, the area- length ejection fraction method in the horizontal long- axis plane estimated median stroke volume at 2.9 mL, cardiac output at 0.4 L/minute, end-diastolic volume at 3.8 mL, end-systolic volume at 0.3 mL, and ejection fraction at 74.6%. Short-axis volumetric estimations were made for 4 infants. With this approach, the median stroke volume was 2.4 mL, cardiac output 0.35 L/minute, end-diastolic volume 4.3 mL, end-systolic volume 2.1 mL, and ejection fraction 56%. CONCLUSIONS. Three-tesla cardiac MRI is feasible for preterm infants without sedation, anesthesia, or breath-holding and has the potential to provide a wide range of precise quantitative data that may be of great value for the investigation of cardiac function in preterm infants.
引用
收藏
页码:78 / 83
页数:6
相关论文
共 50 条
  • [31] Physiological stability of preterm infants during magnetic resonance imaging
    Battin, M
    Maalouf, EF
    Counsell, S
    Herlihy, A
    Hall, A
    Azzopardi, D
    Edwards, AD
    EARLY HUMAN DEVELOPMENT, 1998, 52 (02) : 101 - 110
  • [32] Magnetic Resonance Imaging and Ultrasound Injury in Preterm Infants With Seizures
    Glass, Hannah C.
    Bonifacio, Sonia L.
    Sullivan, Joseph
    Rogers, Elizabeth
    Ferriero, Donna M.
    Goldstein, Ruth
    Barkovich, A. James
    JOURNAL OF CHILD NEUROLOGY, 2009, 24 (09) : 1105 - 1111
  • [33] Functional Magnetic Resonance Imaging of the Sensorimotor System in Preterm Infants
    Heep, Axel
    Scheef, Lukas
    Jankowski, Jakob
    Born, Mark
    Zimmermann, Nadine
    Sival, Deborah
    Bos, Arie
    Gieseke, Juergen
    Bartmann, Peter
    Schild, Hans
    Boecker, Henning
    PEDIATRICS, 2009, 123 (01) : 294 - 300
  • [34] Magnetic resonance imaging at term and neuromotor outcome in preterm infants
    Valkama, AM
    Pääkkö, ELE
    Vainionpää, LK
    Lanning, FP
    Ilkko, EA
    Koivisto, ME
    ACTA PAEDIATRICA, 2000, 89 (03) : 348 - 355
  • [35] Three-Tesla MR imaging of the elbow in non-symptomatic professional baseball pitchers
    Del Grande, Filippo
    Aro, Michael
    Farahani, Sahar Jalali
    Wilckens, John
    Cosgarea, Andrew
    Carrino, John A.
    SKELETAL RADIOLOGY, 2015, 44 (01) : 115 - 123
  • [36] Implantable cardiac defibrillator interactions with magnetic resonance imaging at 1.5 Tesla
    Coman, JA
    Martin, ET
    Sandler, DA
    Thomas, JR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 138A - 138A
  • [37] Magnetic resonance Imaging of Implantable cardiac rhythm devices at 3.0 tesla
    Gimbel, J. Rod
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (07): : 795 - 801
  • [38] Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla
    Martin, ET
    Coman, JA
    Shellock, FG
    Pulling, CC
    Fair, R
    Jenkins, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) : 1315 - 1324
  • [39] Three-Tesla High-Field Applications
    Kim, Peter D.
    Truwit, Charles L.
    Hall, Walter A.
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2009, 20 (02) : 173 - +
  • [40] Megalencephalic Leukoencephalopathy with Subcortical Cysts on Three Tesla Magnetic Resonance Imaging
    Indiran, Venkatraman
    TURKISH JOURNAL OF NEUROLOGY, 2016, 22 (01) : 33 - 34