Measurement of cerebral blood flow with near infrared spectroscopy and indocyanine green dye dilution

被引:1
|
作者
Keller, Emanuela
Mudra, Regina
机构
[1] Univ Zurich Hosp, Dept Neurol, Neurocrit Care Unit, CH-8091 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomed Engn, Zurich, Switzerland
关键词
near infrared spectroscopy; indocyanine green; cerebral blood flow; extracerebral contamination; Monte Carlo simulation; spatially resolved spectroscopy;
D O I
10.2174/157340507780619151
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Early detection and treatment of cerebral ischemia to prevent further neurological damage in patients with severe brain injuries, such as in trauma and stroke patients, is one of the most important issues in Neurocritical Care. Our own clinical experiences in treatment of patients with severe ischemic stroke and subarachnoid hemorrhage have shown that the available methods to monitor cerebral hemodynamics and oxygenation are insufficient with regard to detection of secondary ischemic events. The established methods for bedside monitoring of cerebral blood flow (CBF) and cerebral oxygenation are difficult to perform clinically, involve radioactive radiation, are invasive or require the patient to be transported, thus involving potentially high risks. Transcranial Doppler sonography produces indices that can be related to changes in CBF and cerebral oxygenation but does not measure actual flow rates. During recent years, near infrared spectroscopy (NIRS) was further developed and supplemented with the indocyanine green (ICG) dye dilution mode for bedside monitoring of CBF. The NIRS ICG dye dilution technique is a promising method for serial bedside CBF measurements in the environment of the intensive care unit. The NIRS method with optodes on the skin has the advantage of being non invasive, does not require the patient to be transported and provides data at the bedside within minutes. Preliminary data in a limited number of volunteers indicate that CBF measurements obtained by NIRS ICG dye dilution technique are in agreement with corresponding values obtained by perfusion-weighted MRI. More patient-validated data by correlating the measurement values with clinical events and comparing them with standard methods are needed. For the accuracy of absolute measurements and in order to quantify the individual extracerebral pathlengths as well as to allow appropriate correction to be made for extracerebral dead space tissue further modelling based on patients data is required. New-generation NIRS instrumentation, implementing spatially resolved spectroscopy (SRS), depth-resolved technologies and invasive NIRS probes will give the opportunity to reduce or eliminate extracerebral contamination and will provide some unique physiological information for NIRS technology. To calculate the influence of extracerebral contamination comparative measurements can be performed using noninvasive NIRS probes on the scalp and invasive probes for NIRS and intracranial pressure (ICP) monitoring. Combined monitoring of ICP and NIRS will be of special clinical value in patients with severe stroke, subarachnoid hemorrhage and head trauma, already provided with ICP probes for treatment of intracranial hypertension and being especially at risk for secondary ischemic brain damage.
引用
收藏
页码:139 / 150
页数:12
相关论文
共 50 条
  • [21] Near-infrared spectroscopy and indocyanine green derived blood flow index for noninvasive measurement of muscle perfusion during exercise
    Habazettl, Helmut
    Athanasopoulos, Dimitris
    Kuebler, Wolfgang M.
    Wagner, Harrieth
    Roussos, Charis
    Wagner, Peter D.
    Ungruhe, Juergen
    Zakynthinos, Spyros
    Vogiatzis, Ioannis
    JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (04) : 962 - 967
  • [22] Analysis of near-infrared spectroscopy and indocyanine green dye dilution with Monte Carlo simulation of light propagation in the adult brain
    Mudra, R.
    Nadler, A.
    Keller, E.
    Niederer, P.
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (04)
  • [23] Regional blood flow during exercise in humans measured by near-infrared spectroscopy and indocyanine green
    Boushel, R
    Langberg, H
    Olesen, J
    Nowak, M
    Simonsen, L
    Bülow, J
    Kjær, M
    JOURNAL OF APPLIED PHYSIOLOGY, 2000, 89 (05) : 1868 - 1878
  • [24] Near-infrared spectroscopy and indocyanine green derived blood flow index for noninvasive measurement of muscle perfusion during exercise in COPD
    Louvaris, Zafeiris
    Habazettl, Helmut
    Wagner, Harrieth
    Wagner, Peter
    Zakynthinos, Spyros
    Vogiatzis, Ioannis
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [25] Measurement of cerebral blood flow during cardiopulmonary bypass with near-infrared spectroscopy
    Roberts, IG
    Fallon, P
    Kirkham, FJ
    Kirshbom, PM
    Cooper, CE
    Elliott, MJ
    Edwards, AD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (01): : 94 - 102
  • [26] Measurement of cerebral blood flow in dogs with near infrared spectroscopy in the reflectance mode is invalid
    Newton, CRJC
    Wilson, DA
    Gunnoe, E
    Wagner, B
    Cope, M
    Traystman, RJ
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1997, 17 (06): : 695 - 703
  • [27] Cerebral Blood Flow Measurement by Near-Infrared Spectroscopy During Carotid Endarterectomy
    Kato, Shinya
    Yoshitani, Kenji
    Ohnishi, Yoshihiko
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2016, 28 (04) : 291 - 295
  • [28] Estimation of regional cerebral blood flow distribution in infants by near-infrared topography using indocyanine green
    Kusaka, T
    Isobe, K
    Nagano, K
    Okubo, K
    Yasuda, S
    Kondo, M
    Itoh, S
    Onishi, S
    NEUROIMAGE, 2001, 13 (05) : 944 - 952
  • [29] Cerebral blood flow assessment with indocyanine green bolus transit detection by near-infrared spectroscopy before and after acetazolamide provocation in humans
    Schytz, H. W.
    Wienecke, T.
    Jensen, L. T.
    Selb, J.
    Boas, D. A.
    Ashina, M.
    EUROPEAN JOURNAL OF NEUROLOGY, 2009, 16 (04) : 461 - 467
  • [30] CHOROIDAL BLOOD-FLOW MEASUREMENT IN THE MONKEY BY CLEARANCE OF INDOCYANINE GREEN DYE
    ERNEST, JT
    GOLDSTICK, TK
    EXPERIMENTAL EYE RESEARCH, 1979, 29 (01) : 7 - 14