Dimensions of double-lumen tracheobronchial tubes

被引:20
|
作者
Russell, WJ [1 ]
Strong, TS [1 ]
机构
[1] Royal Adelaide Hosp, Dept Anaesthesia & Intens Care, Adelaide, SA 5000, Australia
关键词
tracheobronchial tubes : measurement; double-lumen; sizing;
D O I
10.1177/0310057X0303100109
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The diameter of the left main bronchus is the determining dimension when selecting the size of a left tracheobronchial (double-lumen) tube for lung separation. However, this information is not given by any manufacturer, either on the tube or in the package insert. This paper describes the lengths and diameters of the deflated bronchial cuff segment of left tracheobronchial tubes in common use. One hundred and seventy-one left tracheobronchial tubes ranging in size from 28 to 41 nominal French gauge from four manufacturers were measured. There was wide variation between tubes of the same nominal size from the same manufacturer For tubes of the same size from the same manufacturer, the diameter of the segment with the deflated bronchial cuff varied by more than I mm in diameter in some instances. The diameter of the bronchial cuff segment did not consistently decrease as the nominal size decreased even for the same manufacturer There was major overlap in diameters of the bronchial segments between Fr 41, Er 39, and Fr 37 tubes from most manufacturers, so that some of the Fr 39 tubes have a bronchial cuff segment diameter as much as 0.5 mm larger than the Fr 41 tube. It is concluded that the current French gauge markings on left tracheobronchial tubes are of very limited value in determining the appropriate size to be selected for a patient. More accurate and consistent dimensions of tracheobronchial tubes are required to improve clinical selection.
引用
收藏
页码:50 / 53
页数:4
相关论文
共 50 条
  • [41] ENDOBRONCHIAL CUFF PRESSURES OF DOUBLE-LUMEN TUBES
    MAGEE, PT
    ANESTHESIA AND ANALGESIA, 1991, 72 (02): : 265 - 266
  • [42] INTRAOPERATIVE MANIPULATION FOR POSITIONING OF DOUBLE-LUMEN TUBES
    COHEN, E
    KIRSCHNER, PA
    GOLDOFSKY, S
    ANESTHESIOLOGY, 1988, 68 (01) : 170 - 170
  • [43] AN AID IN THE DIAGNOSIS OF MALPOSITIONED DOUBLE-LUMEN TUBES
    SIMON, BA
    HURFORD, WE
    ALFILLE, PH
    HASPEL, K
    BEHRINGER, EC
    ANESTHESIOLOGY, 1992, 76 (05) : 862 - 863
  • [44] Fibreoptic bronchoscopic positioning of double-lumen tubes
    Foley, Karen A.
    Slinger, Peter
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2014, 15 (11): : 505 - 508
  • [45] LOW RESISTANCE DOUBLE-LUMEN ENDOBRONCHIAL TUBES
    ROBERTSHAW, FL
    BRITISH JOURNAL OF ANAESTHESIA, 1962, 34 (08) : 576 - &
  • [46] Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes
    Brodsky, JB
    Macario, A
    Mark, JBD
    ANESTHESIA AND ANALGESIA, 1996, 82 (04): : 861 - 864
  • [47] Tracheobronchial laceration after double-lumen intubation for thoracic procedures
    Spaggiari, L
    Rusca, M
    Carbognani, P
    Solli, P
    ANNALS OF THORACIC SURGERY, 1998, 65 (06): : 1837 - 1838
  • [48] GASTRIC ULCERATION - COMPLICATION OF DOUBLE-LUMEN NASOGASTRIC TUBES
    GREENE, JF
    SAWICKI, JE
    DOYLE, WF
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1973, 224 (03): : 338 - 339
  • [49] A comparison of techniques for placement of double-lumen endobronchial tubes
    Boucek, CD
    Landreneau, R
    Freeman, JA
    Strollo, D
    Bircher, NG
    JOURNAL OF CLINICAL ANESTHESIA, 1998, 10 (07) : 557 - 560
  • [50] Challenges encountered with double-lumen tubes: A case report
    Zhang, Liman
    Zhang, Yuanyuan
    Wang, Yu
    Liu, Hong
    ASIAN JOURNAL OF SURGERY, 2024, 47 (11) : 4768 - 4769