Quantitative assessment of ensemble coherency in contrast-free ultrasound microvasculature imaging

被引:10
|
作者
Nayak, Rohit [1 ]
MacNeill, Justin [1 ]
Flores, Cecilia [2 ]
Webb, Jeremy [1 ]
Fatemi, Mostafa [2 ]
Alizad, Azra [1 ,2 ]
机构
[1] Mayo Clin, Coll Med & Sci, Dept Radiol, Rochester, MN 55902 USA
[2] Mayo Clin, Coll Med & Sci, Dept Physiol & Biomed Engn, Rochester, MN 55902 USA
基金
美国国家卫生研究院;
关键词
contrast free microvascular imaging; ensemble coherence; motion tracking and correction; power Doppler imaging; quality metric; ultrafast imaging; FRAME RATE ULTRASONOGRAPHY; PLANE-WAVE; DOPPLER; FLOW;
D O I
10.1002/mp.14918
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Contrast-free visualization of microvascular blood flow (MBF) using ultrasound can play a valuable role in diagnosis and detection of diseases. In this study, we demonstrate the importance of quantifying ensemble coherence for robust MBF imaging. We propose a novel approach to quantify ensemble coherence by estimating the local spatiotemporal correlation (LSTC) image, and evaluate its efficacy through simulation and in vivo studies. Methods The in vivo patient studies included three volunteers with a suspicious breast tumor, 15 volunteers with a suspicious thyroid tumor, and two healthy volunteers for renal MBF imaging. The breast data displayed negligible prior motion and were used for simulation analysis involving synthetically induced motion, to assess its impact on ensemble coherency and motion artifacts in MBF images. The in vivo thyroid data involved complex physiological motion due to its proximity to the pulsating carotid artery, which was used to assess the in vivo efficacy of the proposed technique. Further, in vivo renal MBF images demonstrated the feasibility of using the proposed ensemble coherence metric for curved array-based MBF imaging involving phase conversion. All ultrasound data were acquired at high imaging frame rates and the tissue signal was suppressed using spatiotemporal clutter filtering. Thyroid tissue motion was estimated using two-dimensional normalized cross correlation-based speckle tracking, which was subsequently used for ensemble motion correction. The coherence of the MBF image was quantified based on Casorati correlation of the Doppler ensemble. Results The simulation results demonstrated that an increase in ensemble motion corresponded with a decrease in ensemble coherency, which reciprocally degraded the MBF images. Further the data acquired from breast tumors demonstrated higher ensemble coherency than that from thyroid tumors. Motion correction improved the coherence of the thyroid MBF images, which substantially improved its visualization. The proposed coherence metrics were also useful in assessing the ensemble coherence for renal MBF imaging. The results also demonstrated that the proposed coherence metric can be reliably estimated from downsampled ensembles (by up to 90%), thus allowing improved computational efficiency for potential applications in real-time MBF imaging. Conclusions This pilot study demonstrates the importance of assessing ensemble coherency in contrast-free MBF imaging. The proposed LSTC image quantified coherence of the Doppler ensemble for robust MBF imaging. The results obtained from this pilot study are promising, and warrant further development and in vivo validation.
引用
收藏
页码:3540 / 3558
页数:19
相关论文
共 50 条
  • [21] Contrast-free microscopic assessment of glioblastoma bioposy specimens prior to biobanking
    Georges, Joseph
    Zehri, Aqib
    Carlson, Elizabeth
    Nichols, Joshua
    Mooney, Michael A.
    Martirosyan, Nikolay L.
    Ghaffari, Layla
    Kalani, M. Yashar S.
    Eschbacher, Jennifer
    Feuerstein, Burt
    Anderson, Trent
    Preul, Mark C.
    Van Keuren-Jensen, Kendall
    Nakaji, Peter
    NEUROSURGICAL FOCUS, 2014, 36 (02)
  • [22] Adaptive compensation of TGC effects in contrast-free ultrasensitive ultrasound Doppler imaging for improved resistivity index map visualization
    Chinchilla, Lenin
    Frappart, Thomas
    Fraschini, Christophe
    Correas, Jean-Michel
    Gennisson, Jean-Luc
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [23] High Spatiotemporal Resolution Contrast-Free Ultrasound Microvascular Imaging Using Adaptive Weight-Based Nonlinear Compounding
    Jiang, Liyuan
    Chu, Hanbing
    Liu, Yang
    Liu, Jiacheng
    Su, Xiao
    Yan, Yichen
    Liang, Meiling
    Chen, Yiran
    Zhang, Chaoyang
    Wang, Feiqian
    Zong, Yujin
    Wan, Mingxi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [24] Volumetric imaging and morphometric analysis of breast tumor angiogenesis using a new contrast-free ultrasound technique: a feasibility study
    Gu, Juanjuan
    Ternifi, Redouane
    Sabeti, Soroosh
    Larson, Nicholas B. B.
    Carter, Jodi M. M.
    Fazzio, Robert T. T.
    Fatemi, Mostafa
    Alizad, Azra
    BREAST CANCER RESEARCH, 2022, 24 (01)
  • [25] Volumetric imaging and morphometric analysis of breast tumor angiogenesis using a new contrast-free ultrasound technique: a feasibility study
    Juanjuan Gu
    Redouane Ternifi
    Soroosh Sabeti
    Nicholas B. Larson
    Jodi M. Carter
    Robert T. Fazzio
    Mostafa Fatemi
    Azra Alizad
    Breast Cancer Research, 24
  • [26] Simultaneous Highly Efficient Contrast-Free Lumen and Vessel Wall MR Imaging for Anatomical Assessment of Aortic Disease
    Munoz, Camila
    Fotaki, Anastasia
    Hua, Alina
    Hajhosseiny, Reza
    Kunze, Karl P.
    Ismail, Tevfik F.
    Neji, Radhouene
    Pushparajah, Kuberan
    Botnar, Rene M.
    Prieto, Claudia
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (04) : 1110 - 1122
  • [27] Automatic dissociation between microvasculature and larger vessels for Ultrasound Contrast Imaging
    Perperidis, Antonios
    Thomas, David
    Averkiou, Michalakis
    Duncan, Colin
    McNeilly, Alan
    Butler, Mairead
    Sboros, Vassilis
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5076 - 5079
  • [28] Clutter filtering of angular domain data for contrast-free ultrafast microvascular imaging
    Jiang, Liyuan
    Chu, Hanbing
    Yu, Jianjun
    Su, Xiao
    Liu, Jiacheng
    Wu, Haitao
    Wang, Feiqian
    Zong, Yujin
    Wan, Mingxi
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (01):
  • [29] Intravenous contrast-free standardized exercise perfusion imaging in diabetic feet with ulcers
    Edalati, Masoud
    Hastings, Mary K.
    Muccigrosso, David
    Sorensen, Christopher J.
    Hildebolt, Charles
    Zayed, Mohamed A.
    Mueller, Michael J.
    Zheng, Jie
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (02) : 474 - 480
  • [30] CONTRAST-FREE BLOOD FLOW VELOCITY PROFILE MEASUREMENT WITH ULTRASOUND IN REAL-TIME
    Koutsouridis, G. G.
    Bijnens, N.
    van Geldermalsen, S.
    Brands, P. J.
    van de Vosse, F. N.
    Rutten, M. C. M.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2011, PTS A AND B, 2011, : 1121 - 1122