Pseudophakic eye with obliquely crossed piggyback toric intraocular lenses

被引:13
|
作者
Jin, Haiying [1 ,2 ,3 ]
Limberger, Il-Joo [1 ]
Borkenstein, Andreas F. M. [1 ]
Ehmer, Angela [1 ]
Guo, Haike [2 ]
Auffarth, Gerd U. [1 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, Int Vis Correct Res Ctr, D-69120 Heidelberg, Germany
[2] Guangdong Acad Med Sci, Guangdong Eye Inst, Guangzhou, Guangdong, Peoples R China
[3] Guangdong Gen Hosp Acad Med Sci, Guangdong Eye Inst, Guangzhou, Guangdong, Peoples R China
来源
关键词
IMPLANTATION; ASTIGMATISM;
D O I
10.1016/j.jcrs.2009.07.054
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A 72-year-old man presented with high astigmatism (2.25 - 5.0 x 45) induced by long-term rotation of a toric intraocular lens (IOL). Corneal astigmatism was 3.78 diopters (D). The corrected distance visual acuity (CDVA) was 20/32. Because of the risk of repositioning, a secondary toric IOL of -3.0/6.0 D especially designed for sulcus implantation was piggybacked through 3.5 mm sutureless clear-corneal incision with a cylindrical axis obliquely crossed with that of the primary IOL. Eight months postoperatively, the corneal astigmatism was 5.04 D. The CDVA was 20/25 with a refraction of 1.0 -2.5 x 70. No interlenticular opacification or significant rotation or decentration of the secondary toric IOL was observed. The refractive properties of this pseudophakic eye were analyzed using a mathematical approach. The calculated postoperative refraction was 0.84 -1.7 x 47. A piggyback toric IOL can be implanted in an obliquely crossed style that allows a secondary toric IOL to correct astigmatism induced by long-term toric IOL rotation.
引用
收藏
页码:497 / 502
页数:6
相关论文
共 50 条
  • [21] Toric phakic intraocular lenses
    Dick, H. B.
    Buchner, S. E.
    OPHTHALMOLOGE, 2007, 104 (12): : 1032 - +
  • [22] Determination of toric intraocular lenses
    Langenbucher, A.
    Viestenz, Anja
    Szentmary, N.
    Behrens-Baumann, W.
    Viestenz, A.
    OPHTHALMOLOGE, 2008, 105 (07): : 685 - 692
  • [23] Depth of focus extended intraocular lenses and their optical performances in a pseudophakic eye model
    Wang, Zhao-Qi
    Rao, Feng
    Liu, Yong-Ji
    5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: ADVANCED OPTICAL MANUFACTURING TECHNOLOGIES, 2010, 7655
  • [24] Interlenticular opacification of piggyback acrylic intraocular lenses
    Spencer, TS
    Mamalis, N
    Lane, SS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07): : 1287 - 1290
  • [25] On obliquely-crossed cylindrical lenses.
    Thompson, Silvanus P.
    PHILOSOPHICAL MAGAZINE, 1900, 49 (296-01) : 316 - 324
  • [26] Piggyback silicone intraocular lenses of opposite power
    Till, JS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (01): : 165 - 168
  • [27] Contact zone of piggyback acrylic intraocular lenses
    Findl, O
    Menapace, R
    Rainer, G
    Georgopoulos, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (06): : 860 - 862
  • [28] A novel approach to design intraocular lenses with extended depth of focus in a pseudophakic eye model
    Rao, Feng
    Wang, Zhao-Qi
    Liu, Yong-Ji
    Wang, Yan
    OPTIK, 2011, 122 (11): : 991 - 995
  • [29] Quality of images with toric intraocular lenses
    Tognetto, Daniele
    Perrotta, Alberto Armando
    Bauci, Francesco
    Rinaldi, Silvia
    Antonuccio, Manlio
    Pellegrino, Felice Andrea
    Fenu, Gianfranco
    Stamatelatos, George
    Alpins, Noel
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (03): : 376 - 381
  • [30] Toric intraocular lenses and correction of astigmatism
    Viestenz, Arne
    Walter, S.
    Viestenz, Anja
    Behrens-Baumann, W.
    Langenbucher, A.
    OPHTHALMOLOGE, 2007, 104 (07): : 620 - 627