Effect of particle morphology on the triboelectrification in dry powder inhalers

被引:69
|
作者
Murtomaa, M [1 ]
Mellin, V
Harjunen, P
Lankinen, T
Laine, E
Lehto, VP
机构
[1] Turku Univ, Dept Phys, FIN-20014 Turku, Finland
[2] Univ Kuopio, Dept Pharmaceut, FIN-70211 Kuopio, Finland
[3] Focus Inhalat, FIN-20101 Turku, Finland
关键词
dry powder inhaler; aerosol; electrostatic charge; spray dried lactose;
D O I
10.1016/j.ijpharm.2004.06.002
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Electrostatic charge of lactoses of different particle morphology and amorphous contents were measured during actuation from two different dry powder inhalers (DPIs). Triboelectric studies may give important information when new inhaler devices, materials and formulations are designed in order to improve the drug deposition. Two inhalers, Taifun(TM) (Fpcus Inhalation Oy, Finland) and Clickhaler(TM) (Innovata Biomed Ltd., UK) were filled with lactose powders which were spray dried from different solutions or suspensions of lactose, ethanol and water. Differences in the amorphous contents were determined with isothermal microcalorimetry (IMC) and X-ray diffraction (XRD) and the particle morphology was examined with laser diffraction and electron microscopy (SEM). Samples were actuated from the inhalers at given intervals into the Faraday pail and the generated charges were recorded. Increase in the water concentration of the feed suspension had negligible effect on the charging until it exceeded 70%. Reproducibility of the measurement was found to be better with samples of homogenous particles and higher crystallinity while more amorphous samples with different morphology and wide particle size distribution showed change in the sign of the charge in addition to higher variations of the magnitude. In this study we show that different inhalers, as well as the morphology of the lactose powder, has noticeable effects on the generated charge which has previously been shown to affect the deposition of the drug and the function of an inhaler. (C) 2004, Elsevier B.V. All rights reserved.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 50 条
  • [31] Dry Powder Inhalers for Delivery of Synthetic Biomolecules
    Omidian, Hossein
    Nokhodchi, Ali
    Babanejad, Niloofar
    PHARMACEUTICALS, 2025, 18 (02)
  • [32] Dry powder inhalers - between the doctor and the patient
    Emeryk, Andrzej
    Pirozynski, Michal
    Emeryk-Maksymiuk, Justyna
    ADVANCES IN RESPIRATORY MEDICINE, 2018, 86 (01) : 44 - 52
  • [33] Dry Powder Inhalers: From Bench to Bedside
    Chrystyn, Henry
    Azouz, Wahida
    Tarsin, Walid
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2023, 36 (06) : 324 - 335
  • [34] Towards the optimisation and adaptation of dry powder inhalers
    Cui, Y.
    Schmalfuss, S.
    Zellnitz, S.
    Sommerfeld, M.
    Urbanetz, N.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2014, 470 (1-2) : 120 - 132
  • [35] Patient preference in the choice of dry powder inhalers
    Giner, J
    Torrejón, A
    Ramos, A
    Casan, P
    Granel, C
    Plaza, V
    Belda, J
    Sanchis, J
    ARCHIVOS DE BRONCONEUMOLOGIA, 2004, 40 (03): : 106 - 109
  • [36] Dry-powder inhalers in acute asthma
    Selroos, Olof
    THERAPEUTIC DELIVERY, 2014, 5 (01) : 69 - 81
  • [37] Are outcomes the same with all dry powder inhalers?
    Thomas, M
    Williams, AE
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2005, 59 : 33 - 35
  • [38] Influence of carrier on the performance of dry powder inhalers
    Saint-Lorant, G.
    Leterme, P.
    Gayot, A.
    Flament, M. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2007, 334 (1-2) : 85 - 91
  • [39] Dry powder inhalers for optimal drug delivery
    Newman, SP
    EXPERT OPINION ON BIOLOGICAL THERAPY, 2004, 4 (01) : 23 - 33
  • [40] Investigation of aerodynamic resistance of dry powder inhalers
    Sosnowski, TR
    Gradon, L
    INZYNIERIA CHEMICZNA I PROCESOWA, 2004, 25 (03): : 1619 - 1624