Noise reduction and signal to noise ratio improvement in magneto-optical polarization rotation measurement

被引:5
|
作者
Basharat, Muhammad [1 ]
Ding, Ming [1 ]
Li, Yang [1 ]
Cai, Hongwei [1 ]
Fang, Jiancheng [1 ]
机构
[1] Beihang Univ, Sch Instrumentat Sci & Optoelect Engn, Beijing 100191, Peoples R China
基金
国家重点研发计划; 美国国家科学基金会;
关键词
TERBIUM GALLIUM GARNET; VERDET CONSTANT; TEMPERATURE; SENSOR;
D O I
10.3788/COL201816.081201
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The measurement of an extremely small magneto-optical polarization rotation angle with high sensitivity is integral to many scientific and technological applications. In this Letter, we have presented a technique based on Faraday modulation combined with the optical differential method to measure an extremely small polarization rotation angle with high sensitivity. The theoretical and experimental results show that common mode noise is reduced appreciably and signal to noise ratio is enhanced. The effectiveness of this technique has been demonstrated by measuring the Verdet constant of terbium gallium garnet glass and measuring the small polarization rotation angle. A sensitivity of enhancement of one order of magnitude has been achieved using differential detection based on Faraday modulation.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] SIGNAL TO NOISE RATIO IMPROVEMENT BY FREQUENCY DIVISION IN PRESENCE OF BANDPASS NOISE
    TEPEDELENLIOGLU, N
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1976, 12 (04) : 503 - 505
  • [32] MEASUREMENT OF OSCILLATOR-STRENGTHS IN THE ULTRAVIOLET BY MAGNETO-OPTICAL ROTATION
    GARTON, WRS
    CONNERADE, JP
    BAIG, MA
    HORMES, J
    ALEXA, B
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1983, 16 (03) : 389 - &
  • [33] Medium resolution magneto-optical Faraday rotation measurement system
    Dhara, S
    Moorthy, VN
    Rastogi, AC
    Das, BK
    BULLETIN OF MATERIALS SCIENCE, 1995, 18 (08) : 1031 - 1034
  • [34] SYSTEM FOR SUPPRESSING INTERFERENCE, DRIFT, AND NOISE IN MAGNETO-OPTICAL APPARATUS
    DUDOROV, VN
    LOGUNOV, MV
    RANDOSHKIN, VV
    CHERVENKOV, VD
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1985, 28 (01) : 159 - 161
  • [35] Noise imaging using magneto-optical sampling techniques (invited)
    Freeman, M.R., 1600, American Institute of Physics Inc. (91):
  • [36] Noise imaging using magneto-optical sampling techniques (invited)
    Freeman, MR
    Steeves, GM
    Ballentine, GE
    Krichevsky, A
    JOURNAL OF APPLIED PHYSICS, 2002, 91 (10) : 7326 - 7330
  • [37] USE OF AN AVALANCHE PHOTODIODE FOR REDUCING THE NOISE OF A MAGNETO-OPTICAL CONVERTER
    BOGOLYUBOV, AV
    PANIN, VV
    STEPANOV, BM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1984, 27 (01) : 188 - 191
  • [38] Noise spectroscopy of nonlinear magneto-optical resonances in Rb vapor
    Martinelli, M
    Valente, P
    Failache, H
    Felinto, D
    Cruz, LS
    Nussenzveig, P
    Lezama, A
    PHYSICAL REVIEW A, 2004, 69 (04): : 043809 - 1
  • [39] Optical coherence tomography by "spectral radar":: Improvement of signal-to-noise ratio
    Andretzky, P
    Knauer, M
    Kiesewetter, F
    Häusler, G
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS IV, 2000, 3915 : 55 - 59
  • [40] Improvement of signal to noise ratio in electro optical probing technique by wavelets filtering
    Boscaro, A.
    Jacquir, S.
    Sanchez, K.
    Perdu, P.
    Binczak, S.
    MICROELECTRONICS RELIABILITY, 2015, 55 (9-10) : 1585 - 1591