Detection of Escherichia coli with a label-free impedimetric biosensor based on lectin functionalized mixed self-assembled monolayer

被引:66
|
作者
Yang, Haiying [1 ]
Zhou, Huafeng [2 ]
Hao, Haoyong [1 ]
Gong, Qiaojuan [1 ]
Nie, Kai [1 ]
机构
[1] Yuncheng Univ, Dept Chem, Yuncheng 044300, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Sci, Xian 710055, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2016年 / 229卷
关键词
Biosensor; Electrochemical impedance spectroscopy; Escherichia coli; Concanavalin A; Mixed self-assembled monolayer; PATHOGENIC BACTERIA; SENSITIVE DETECTION; IMMUNOSENSOR; QUANTIFICATION; CARBOHYDRATE; NANOPARTICLES; RECOGNITION; SENSOR; MICROARRAY; O157H7;
D O I
10.1016/j.snb.2015.08.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive impedimetric lectin-based biosensor for the determination of Escherichia coli (E. coil) was developed based on the affinity of lectin with glycosyl complex on cellular surface. The biosensor was fabricated by co-assembling 11-mercaptoundecanoic acid (MUA) and dithiothreitol (DTT) on the surface of gold electrode, and then the lectin was covalently immobilized using carbodiimide chemistry. A well-known lectin, Concanavalin A (Con A) was used to demonstrate proof-of-concept of the recognition interface. In the measurement of E. coli DH5 (as a model target), the change in interfacial electron transfer resistance of lectin-based biosensor was monitored using a redox couple of Fe(CN)(6)(3-/4-). The increase in the electron transfer resistance was in logarithmically direct proportion to the concentration of E. coli over a range from 1.0 x 10(2) to 1.0 x 10(5) cells/mL. The detection limit of this sensor was 75 cells/mL. Additionally, the EIS biosensor also showed satisfactory selectivity in discriminating gram negative E. coli from gram-positive bacteria. The strategy developed in this study may be a promising approach and could be extended to the design of EIS biosensors for highly sensitive and rapid detection of other desired bacteria. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:297 / 304
页数:8
相关论文
共 50 条
  • [21] Microfabricated Capacitive Microwave Biosensor for Label-free Escherichia Coli Bacteria Detection
    Pierkarz, Ilona
    Sorocki, Jakub
    Gorska, Sabina
    Wincza, Krzysztof
    Gruszczynski, Slawomir
    2023 53RD EUROPEAN MICROWAVE CONFERENCE, EUMC, 2023, : 564 - 567
  • [22] Atrazine analysis using an impedimetric immunosensor based on mixed biotinylated self-assembled monolayer
    Hleli, S
    Martelet, C
    Abdelghani, A
    Burais, N
    Jaffrezic-Renault, N
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) : 711 - 717
  • [23] Development of a myoglobin impedimetric immunosensor based on mixed self-assembled monolayer onto gold
    Billah, Morsaline
    Hays, Henry C. W.
    Millner, Paul A.
    MICROCHIMICA ACTA, 2008, 160 (04) : 447 - 454
  • [24] Development of a myoglobin impedimetric immunosensor based on mixed self-assembled monolayer onto gold
    Morsaline Billah
    Henry C. W. Hays
    Paul A. Millner
    Microchimica Acta, 2008, 160 : 447 - 454
  • [25] A reusable and label-free supersandwich biosensor for sensitive DNA detection by immobilizing target-triggered DNA concatamers on ternary self-assembled monolayer
    Ren, Wang
    Zhou, Long Yin
    Zhang, Ying
    Li, Nian Bing
    Luo, Hong Qun
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 223 : 24 - 29
  • [26] A sensitive label-free impedimetric DNA biosensor based on silsesquioxane-functionalized gold nanoparticles for Zika Virus detection
    Steinmetz, Marines
    Lima, Dhesmon
    Viana, Adriano Goncalves
    Fujiwara, Sergio Toshio
    Pessoa, Christiana Andrade
    Etto, Rafael Mazer
    Wohnrath, Karen
    BIOSENSORS & BIOELECTRONICS, 2019, 141
  • [27] Label-Free Impedimetric Sensor for a Ribonucleic Acid Oligomer Specific to Hepatitis C Virus at a Self-Assembled Monolayer-Covered Electrode
    Park, Jin-Young
    Lee, Yoon-suk
    Chang, Byoung-Yong
    Kim, Byeang Hyean
    Jeon, Sangmin
    Park, Su-Moon
    ANALYTICAL CHEMISTRY, 2010, 82 (19) : 8342 - 8348
  • [28] Label-free Immunosensor Using a Gold Electrode Covered with Conductive Self-assembled Monolayer
    Takoh, Kimiyasu
    Horie, Mika
    Someya, Hiroko
    Ishida, Masahiko
    Kamijo, Ken'ichi
    2010 IEEE SENSORS, 2010, : 411 - 414
  • [29] Electrochemical studies of cystine modified self-assembled monolayer for Escherichia coli detection
    Pandey, Chandra Mouli
    Sumana, Gajjala
    Sood, K. N.
    Malhotra, B. D.
    THIN SOLID FILMS, 2010, 519 (03) : 1178 - 1183
  • [30] Functionalized-Graphene Field Effect Transistor-Based Biosensor for Ultrasensitive and Label-Free Detection of β-Galactosidase Produced by Escherichia coli
    Wei, Shanhong
    Dou, Yanzhi
    Song, Shiping
    Li, Tie
    BIOSENSORS-BASEL, 2023, 13 (10):