Influence of Applied Voltages on Mechanical Properties and In-Vitro Performances of Electroplated Hydroxyapatite Coatings on Pure Titanium

被引:10
|
作者
Chen, Shih-Hsun [1 ,2 ]
Tsai, Wei-Lin [3 ]
Chen, Po-Chun [3 ]
Fang, Alex [2 ]
Say, Wen-Ching [3 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Mech Engn, Taipei 10607, Taiwan
[2] Texas A&M Univ, Dept Engn Technol & Ind Distribut, College Stn, TX 77843 USA
[3] Natl Taipei Univ Technol, Inst Mat Sci & Engn, Taipei 10608, Taiwan
关键词
COMPOSITE; CALCIUM; BIOMATERIALS; PROSTHESES; CERAMICS; IMPLANTS; SURFACE;
D O I
10.1149/2.1001607jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Titanium and its alloys have been extensively used in biomaterials due to their bone-compatible modulus, superior bio-compatibility and enhanced corrosion resistance. But the metal implants that contact the body will release ions and scraps. In this study, Hydroxyapatite (HA, Ca-10(PO4)(6)(OH)(2)) was coated on a pure Ti substrate by electrochemical deposition process, which can provide a well-controlled process and product. Across various applied voltages, the electroplated HA/Ti composites were evaluated on their chemical and mechanical performances and the behaviors of in-vitro simulating tests. Highly pure HA coatings were obtained with additional voltages from 16 V to 19 V. In addition, their mechanical properties were significantly enhanced with increasing voltages. With the results of in-vitro evaluations, the electroplated HA/Ti composites is capable of serving as a biomaterial for bone substitution or implantation. (C) The Author(s) 2016. Published by ECS. This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 License (CC BY, http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse of the work in any medium, provided the original work is properly cited. All rights reserved.
引用
收藏
页码:D305 / D308
页数:4
相关论文
共 50 条
  • [41] Characterization, mechanical and in vitro biological behavior of hydroxyapatite-titanium-carbon nanotube composite coatings deposited on NiTi alloy by electrophoretic deposition
    Maleki-Ghaleh, Hossein
    Khalil-Allafi, Jafar
    SURFACE & COATINGS TECHNOLOGY, 2019, 363 : 179 - 190
  • [42] Influence of the addition of carbonated hydroxyapatite and selenium dioxide on mechanical properties and in vitro bioactivity of borosilicate inert glass
    Youness, Rasha A.
    Taha, Mohammed A.
    El-Kheshen, Amany A.
    Ibrahim, Medhat
    CERAMICS INTERNATIONAL, 2018, 44 (17) : 20677 - 20685
  • [43] Physico-mechanical properties of two different heat treated Nickel-Titanium instruments: in-vitro study
    Schiavon, Riccardo
    Pelliccioni, Gian Andrea
    Zamparini, Fausto
    Bolelli, Giovanni
    Spinelli, Andrea
    Pirani, Chiara
    Iacono, Francesco
    Gandolfi, Maria Giovanna
    Prati, Carlo
    Generali, Luigi
    GIORNALE ITALIANO DI ENDODONZIA, 2024, 38 (01): : 28 - 36
  • [44] Carbonated Hydroxyapatite-Based Honeycomb Scaffold Coatings on a Titanium Alloy for Bone Implant Application-Physicochemical and Mechanical Properties Analysis
    Sari, Mona
    Kristianto, Nicholas Adi
    Chotimah
    Ana, Ika Dewi
    Yusuf, Yusril
    COATINGS, 2021, 11 (08)
  • [45] Influence of gas flow rate on the microstructure and mechanical properties of hydroxyapatite coatings fabricated by gas tunnel type plasma spraying
    Morks, M. F.
    Kobayashi, Akira
    SURFACE & COATINGS TECHNOLOGY, 2006, 201 (06): : 2560 - 2566
  • [46] Deposition of hydroxyapatite coatings by axial plasma spraying: Influence of feedstock characteristics on coating microstructure, phase content and mechanical properties
    Ganvir, Ashish
    Markocsan, Nicolaie
    Balani, Kantesh
    Nagar, Sainyam
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2021, 41 (08) : 4637 - 4649
  • [47] Bias voltage influence on the mechanical and tribological properties of titanium aluminum nitride coatings produced by triode magnetron sputtering
    Devia Narvaez, Diana Marcela
    Velez Restrepo, Juan Manuel
    Restrepo Parra, Elisabeth
    MATERIA-RIO DE JANEIRO, 2015, 20 (01): : 115 - 126
  • [48] Characterization of thick titanium plasma spray coatings on PEEK materials used for medical implants and the influence on the mechanical properties
    Vogel, Danny
    Dempwolf, Henry
    Baumann, Axel
    Bader, Rainer
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 77 : 600 - 608
  • [49] The influence of the concept of "line energy" on the mechanical properties of laser formed commercially pure grade 2 titanium alloy plates
    Mjali, Kadephi Vuyolwethu
    Botes, Annelize
    46TH SME NORTH AMERICAN MANUFACTURING RESEARCH CONFERENCE, NAMRC 46, 2018, 26 : 267 - 275
  • [50] Influence of chitosan and hydroxyapatite incorporation on properties of electrospun PVA/HA nanofibrous mats for bone tissue regeneration: Nanofibers optimization and in-vitro assessment
    Salim, Samar A.
    Loutfy, Samah A.
    El-Fakharany, Esmail M.
    Taha, Tarek H.
    Hussien, Yasmen
    Kamoun, Elbadawy A.
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2021, 62