Influence of Applied Voltages on Mechanical Properties and In-Vitro Performances of Electroplated Hydroxyapatite Coatings on Pure Titanium

被引:10
|
作者
Chen, Shih-Hsun [1 ,2 ]
Tsai, Wei-Lin [3 ]
Chen, Po-Chun [3 ]
Fang, Alex [2 ]
Say, Wen-Ching [3 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Mech Engn, Taipei 10607, Taiwan
[2] Texas A&M Univ, Dept Engn Technol & Ind Distribut, College Stn, TX 77843 USA
[3] Natl Taipei Univ Technol, Inst Mat Sci & Engn, Taipei 10608, Taiwan
关键词
COMPOSITE; CALCIUM; BIOMATERIALS; PROSTHESES; CERAMICS; IMPLANTS; SURFACE;
D O I
10.1149/2.1001607jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Titanium and its alloys have been extensively used in biomaterials due to their bone-compatible modulus, superior bio-compatibility and enhanced corrosion resistance. But the metal implants that contact the body will release ions and scraps. In this study, Hydroxyapatite (HA, Ca-10(PO4)(6)(OH)(2)) was coated on a pure Ti substrate by electrochemical deposition process, which can provide a well-controlled process and product. Across various applied voltages, the electroplated HA/Ti composites were evaluated on their chemical and mechanical performances and the behaviors of in-vitro simulating tests. Highly pure HA coatings were obtained with additional voltages from 16 V to 19 V. In addition, their mechanical properties were significantly enhanced with increasing voltages. With the results of in-vitro evaluations, the electroplated HA/Ti composites is capable of serving as a biomaterial for bone substitution or implantation. (C) The Author(s) 2016. Published by ECS. This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 License (CC BY, http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse of the work in any medium, provided the original work is properly cited. All rights reserved.
引用
收藏
页码:D305 / D308
页数:4
相关论文
共 50 条
  • [1] Surface and mechanical properties of a nanostructured citrate hydroxyapatite coating on pure titanium
    Arres, Mar
    Salama, Mariana
    Rechena, Diogo
    Paradiso, Patrizia
    Reis, Luis
    Alves, Marta M.
    Botelho do Rego, Ana M.
    Carmezim, Maria J.
    Vaz, Maria Fatima
    Deus, Augusto M.
    Santos, Catarina
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 108
  • [2] Mechanical properties, microstructural characteristics and in-vitro behavior of APS-sprayed nanostructured and conventional hydroxyapatite coatings
    Lima, RS
    Marple, BR
    Khor, KA
    Li, H
    Cheang, P
    THERMAL SPRAY 2004: ADVANCES IN TECHNOLOGY AND APPLICATION, PROCEEDINGS, 2004, : 157 - 162
  • [3] The influence of electrical potential on the mechanical properties of commercially pure titanium
    Osintsev, K. A.
    Komissarova, I. A.
    Konovalov, S., V
    Voronin, S. V.
    Chen, X.
    LETTERS ON MATERIALS, 2020, 10 (04): : 512 - 516
  • [4] Influence of Detonation Spraying Parameters on the Microstructure and Mechanical Properties of Hydroxyapatite Coatings
    Sagdoldina, Zhuldyz
    Kot, Marcin
    Baizhan, Daryn
    Buitkenov, Dastan
    Sulyubayeva, Laila
    MATERIALS, 2024, 17 (21)
  • [5] The Influence of Hard Coatings on Fatigue Properties of Pure Titanium by a Novel Testing Method
    Hu, Cai
    Zhao, Lei
    Zhang, Yong
    Du, Zhinan
    Deng, Yunlai
    MATERIALS, 2024, 17 (04)
  • [6] Improvement of Mechanical and Corrosion Properties of Commercially Pure Titanium Using Alumina PEO Coatings
    Malinovschi, Viorel
    Marin, Alexandru Horia
    Ducu, Catalin
    Moga, Sorin
    Andrei, Victor
    Coaca, Elisabeta
    Craciun, Valentin
    Lungu, Mihail
    Lungu, Cristian P.
    COATINGS, 2022, 12 (01)
  • [7] The influence of chemical polishing of titanium scaffolds on their mechanical strength and in-vitro cell response
    Wysocki, Bartlomiej
    Idaszek, Joanna
    Buhagiar, Joseph
    Szlazak, Karol
    Brynk, Tomasz
    Kurzydlowski, Krzysztof J.
    Swieszkowski, Wojciech
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 95 : 428 - 439
  • [8] Influence of Surface Roughness on the Adhesion of Hydroxyapatite Coatings to Titanium and Titanium Alloy Surfaces: A Systematic Review of in vitro Experimental Studies
    de Melo-Soares, Victor
    Gazott-Simoes, Isadora
    dos Reis, Andrea Candido
    Valente, Mariana Lima da Costa
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2025, 33 (01): : 93 - 103
  • [9] Enhanced mechanical properties and in vitro cell response of surface mechanical attrition treated pure titanium
    Zhao, Changli
    Han, Pei
    Ji, Weiping
    Zhang, Xiaonong
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2012, 27 (02) : 113 - 118
  • [10] Mechanical and in vitro biological performances of hydroxyapatite-carbon nanotube composite coatings deposited on Ti by aerosol deposition
    Hahn, Byung-Dong
    Lee, Jung-Min
    Park, Dong-Soo
    Choi, Jong-Jin
    Ryu, Jungho
    Yoon, Woon-Ha
    Lee, Byoung-Kuk
    Shin, Du-Sik
    Kim, Hyoun-Ee
    ACTA BIOMATERIALIA, 2009, 5 (08) : 3205 - 3214