Test-retest reliability of ERP components: A short-term replication of a visual Go/NoGo task in ADHD subjects

被引:26
|
作者
Kompatsiari, Kyveli [1 ]
Candrian, Gian [1 ]
Mueller, Andreas [1 ]
机构
[1] Brain & Trauma Fdn Grisons, Poststr 22, CH-7000 Chur, Switzerland
关键词
Test-retest reliability; Event-related potentials; Independent components; ADHD; Visual continuous performance task; Intraclass correlation coefficient; EVENT-RELATED POTENTIALS; INDEPENDENT COMPONENTS; ATTENTION; CHILDREN; MISMATCH; INHIBITION; DURATION; P300;
D O I
10.1016/j.neulet.2016.02.012
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Event-related potentials (ERPs) have been widely used to investigate brain functioning in children with Attention Deficit Hyperactivity Disorder (ADHD) in both research and diagnostic settings. To ensure the efficiency of ERP techniques in ADHD diagnosis and in longitudinal observational studies, the test-retest reliability of the affected population must be validated. Thus, the present article assesses the short-term test-retest reliability of certain early and late ERPs (i.e., P1, N1, N2, P2, P3), as well as independent components (ICs) decomposed from the above mentioned ERPs (IC P3 Go, IC P3 NoGo early, IC P3 NoGo late) relevant to ADHD, through the Intraclass Correlation Coefficient (ICC). More specifically, we employ a cued visual Go/NoGo paradigm for recording ERPs from 22 children with ADHD (mean age 12.2), twice within 30 min. Amplitudes and latencies are calculated by the 'peak amplitude' method and by a variation of the fractional area. Results for amplitudes lie mostly within the 'good' and 'excellent' range for both measurement methods, while ICC for latencies is more variable ranging from 'poor' to 'excellent' results. Crucially, the ICs, which are associated with distinct functionally independent processes of the executive attentional system have shown a comparable test-retest reliability with the raw ERPs. Our results are consistent with other reliability studies of neurotypical population in the literature, and as such, consist initial evidence that ERPs could be reliable neurophysiological markers for the ADHD population. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:166 / 172
页数:7
相关论文
共 50 条
  • [21] Test-Retest Reliability of the Timed Up and Go Test in Subjects with Parkinson's Disease: Implications for Longitudinal Assessments
    Luque-Casado, Antonio
    Novo-Ponte, Sabela
    Andres Sanchez-Molina, Jose
    Sevilla-Sanchez, Marta
    Santos-Garcia, Diego
    Fernandez-del-Olmo, Miguel
    JOURNAL OF PARKINSONS DISEASE, 2021, 11 (04) : 2047 - 2055
  • [22] Short-Term Test-Retest Reliability of Electrically Evoked Cortical Auditory Potentials in Adult Cochlear Implant Recipients
    Pike, Meghan
    Biagio-de Jager, Leigh
    le Roux, Talita
    Hofmeyr, Louis M.
    FRONTIERS IN NEUROLOGY, 2020, 11
  • [23] Morpho-Functional 1H-MRI of the Lung in COPD: Short-Term Test-Retest Reliability
    Jobst, Bertram J.
    Wielpuetz, Mark O.
    Triphan, Simon M. F.
    Anjorin, Angela
    Ley-Zaporozhan, Julia
    Kauczor, Hans-Ulrich
    Biederer, Juergen
    Ley, Sebastian
    Sedlaczek, Oliver
    PLOS ONE, 2015, 10 (09):
  • [24] Regional electroencephalogram (EEG) alpha power and asymmetry in older adults: a study of short-term test-retest reliability
    Mathewson, Karen J.
    Hashemi, Ali
    Sheng, Bruce
    Sekuler, Allison B.
    Bennett, Patrick J.
    Schmidt, Louis A.
    FRONTIERS IN AGING NEUROSCIENCE, 2015, 7
  • [25] Test-retest reliability and short-term variability of quantitative light reflex pupillometry in a mixed memory clinic cohort
    Gramkow, Mathias Holsey
    Clemmensen, Frederikke Kragh
    Waldemar, Gunhild
    Hasselbalch, Steen Gregers
    Frederiksen, Kristian Steen
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2024, 456
  • [26] Biomechanical measures of short-term maximal cycling on an ergometer: a test-retest study
    Burnie, Louise
    Barratt, Paul
    Davids, Keith
    Worsfold, Paul
    Wheat, Jon
    SPORTS BIOMECHANICS, 2023, 22 (08) : 997 - 1015
  • [27] PET-FDG TEST-RETEST RELIABILITY DURING A VISUAL-DISCRIMINATION TASK IN SCHIZOPHRENIA
    HOLCOMB, HH
    CASCELLA, NG
    MEDOFF, DR
    GASTINEAU, EA
    LOATS, H
    THAKER, GK
    CONLEY, RR
    DANNALS, RF
    WAGNER, HN
    TAMMINGA, CA
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (05) : 704 - 709
  • [28] Short Term Test-Retest Reliability of Contralateral Inhibition of Distortion Product Otoacoustic Emissions
    Kalaiah, Mohan Kumar
    Lasrado, Alina
    Pinto, Nikita
    Shastri, Usha
    JOURNAL OF AUDIOLOGY AND OTOLOGY, 2018, 22 (04): : 189 - 196
  • [29] Test-retest reliability of eye tracking during the visual probe task in cocaine-using adults
    Marks, Katherine R.
    Pike, Erika
    Stoops, William W.
    Rush, Craig R.
    DRUG AND ALCOHOL DEPENDENCE, 2014, 145 : 235 - 237
  • [30] Short-term test-retest reliability of resting state fMRI metrics in children with and without attention-deficit/hyperactivity disorder
    Somandepalli, Krishna
    Kelly, Clare
    Reiss, Philip T.
    Zuo, Xi-Nian
    Craddock, R. C.
    Yan, Chao-Gan
    Petkova, Eva
    Castellanos, F. X.
    Milham, Michael P.
    Di Martino, Adriana
    DEVELOPMENTAL COGNITIVE NEUROSCIENCE, 2015, 15 : 83 - 93