Biomechanical evaluation of immediate stability with rectangular versus cylindrical interbody cages in stabilization of the lumbar spine

被引:7
|
作者
Sengupta, DK [1 ]
Mehdian, SMH
Mulholland, RC
Webb, JK
Ohnmeiss, DD
机构
[1] William Beaumont Hosp, Royal Oak, MI 48072 USA
[2] Univ Nottingham Hosp, Queens Med Ctr, Ctr Spinal Studies & Surg, Nottingham NG7 2UH, England
[3] Texas Hlth Res Inst, Plano, TX USA
关键词
D O I
10.1186/1471-2474-3-23
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Recent cadaver studies show stability against axial rotation with a cylindrical cage is marginally superior to a rectangular cage. The purpose of this biomechanical study in cadaver spine was to evaluate the stability of a new rectangular titanium cage design, which has teeth similar to the threads of cylindrical cages to engage the endplates. Methods: Ten motion segments (five L2-3, five L4-5) were tested. From each cadaver spine, one motion segment was fixed with a pair of cylindrical cages (BAK, Sulzer Medica) and the other with paired rectangular cages (Rotafix, Corin Spinal). Each specimen was tested in an unconstrained state, after cage introduction and after additional posterior translaminar screw fixation. The range of motion (ROM) in flexion-extension, lateral bending, and rotation was tested in a materials testing machine, with +/- 5 Nm cyclical load over 10 sec per cycle; data from the third cycle was captured for analysis. Results: ROM in all directions was significantly reduced (p < 0.05) with both types of cages. There was no significant difference in reduction of ROM in flexion-extension (p = 0.6) and rotation (p = 0.92) between the two cage groups, but stability in lateral bending was marginally superior with the rectangular cages (p = 0.11). Additional posterior fixation further reduced the ROM significantly (p < 0.05) in most directions in both cage groups, but did not show any difference between the cage groups. Conclusions: There was no significant difference in immediate stability in any direction between the threaded cylindrical cage and the new design of the rectangular cage with endplate teeth.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [41] MULTISEGMENTAL ANTERIOR STABILIZATION OF THE LUMBAR SPINE - A COMPARATIVE BIOMECHANICAL INVESTIGATION
    EYSEL, P
    HOPF, C
    DIOP, A
    LAVASTE, F
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1995, 133 (03): : 242 - 248
  • [42] Intraspinal metalloma causing lumbar stenosis after interbody fusion with cylindrical titanium cages
    Fernandez-Baillo, Nicomedes
    Sanchez Marquez, Jose Miguel
    Conde Gallego, Esther
    Martin Esteban, Ana
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (06): : 811 - 814
  • [43] Comparative Biomechanical Analysis of Anterior Lumbar Interbody Fusion and Bilateral Expandable Transforaminal Lumbar Interbody Fusion Cages: A Finite Element Analysis Study
    Bakhaidar, Mohamad
    Harinathan, Balaji
    Devaraj, Karthik Banurekha
    DeGroot, Andrew
    Yoganandan, Narayan
    Shabani, Saman
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2024, 18 (04):
  • [44] A BIOMECHANICAL ANALYSIS OF THE CLINICAL STABILITY OF THE LUMBAR AND LUMBOSACRAL SPINE
    POSNER, I
    WHITE, AA
    EDWARDS, WT
    HAYES, WC
    SPINE, 1982, 7 (04) : 374 - 389
  • [45] Biomechanical evaluation of anterior cervical spine stabilization
    Grubb, MR
    Currier, BL
    Shih, JS
    Bonin, V
    Grabowski, JJ
    Chao, EYS
    SPINE, 1998, 23 (08) : 886 - 892
  • [46] Biomechanical analysis of lumbar interbody fusion supplemented with various posterior stabilization systems
    Fan, Wei
    Guo, Li-Xin
    Zhang, Ming
    EUROPEAN SPINE JOURNAL, 2021, 30 (08) : 2342 - 2350
  • [47] Biomechanical evaluation of lateral lumbar interbody fusion with secondary augmentation
    Reis, Marco T.
    Reyes, Phillip M.
    Altun, Idris
    Newcomb, Anna G. U. S.
    Singh, Vaneet
    Chang, Steve W.
    Kelly, Brian P.
    Crawford, Neil R.
    JOURNAL OF NEUROSURGERY-SPINE, 2016, 25 (06) : 720 - 726
  • [48] Biomechanical evaluation of posterior and anterior lumbar interbody fusion techniques
    Voor, MJ
    Mehta, S
    Wang, M
    Zhang, YM
    Mahan, J
    Johnson, JR
    JOURNAL OF SPINAL DISORDERS, 1998, 11 (04): : 328 - 334
  • [49] A biomechanical and histological evaluation of a bioresorbable lumbar interbody fusion cage
    Hojo, Y
    Kotani, Y
    Ito, M
    Abumi, K
    Kadosawa, T
    Shikinami, Y
    Minami, A
    BIOMATERIALS, 2005, 26 (15) : 2643 - 2651
  • [50] Biomechanical analysis of lumbar interbody fusion supplemented with various posterior stabilization systems
    Wei Fan
    Li-Xin Guo
    Ming Zhang
    European Spine Journal, 2021, 30 : 2342 - 2350