Biomechanical evaluation of immediate stability with rectangular versus cylindrical interbody cages in stabilization of the lumbar spine

被引:7
|
作者
Sengupta, DK [1 ]
Mehdian, SMH
Mulholland, RC
Webb, JK
Ohnmeiss, DD
机构
[1] William Beaumont Hosp, Royal Oak, MI 48072 USA
[2] Univ Nottingham Hosp, Queens Med Ctr, Ctr Spinal Studies & Surg, Nottingham NG7 2UH, England
[3] Texas Hlth Res Inst, Plano, TX USA
关键词
D O I
10.1186/1471-2474-3-23
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Recent cadaver studies show stability against axial rotation with a cylindrical cage is marginally superior to a rectangular cage. The purpose of this biomechanical study in cadaver spine was to evaluate the stability of a new rectangular titanium cage design, which has teeth similar to the threads of cylindrical cages to engage the endplates. Methods: Ten motion segments (five L2-3, five L4-5) were tested. From each cadaver spine, one motion segment was fixed with a pair of cylindrical cages (BAK, Sulzer Medica) and the other with paired rectangular cages (Rotafix, Corin Spinal). Each specimen was tested in an unconstrained state, after cage introduction and after additional posterior translaminar screw fixation. The range of motion (ROM) in flexion-extension, lateral bending, and rotation was tested in a materials testing machine, with +/- 5 Nm cyclical load over 10 sec per cycle; data from the third cycle was captured for analysis. Results: ROM in all directions was significantly reduced (p < 0.05) with both types of cages. There was no significant difference in reduction of ROM in flexion-extension (p = 0.6) and rotation (p = 0.92) between the two cage groups, but stability in lateral bending was marginally superior with the rectangular cages (p = 0.11). Additional posterior fixation further reduced the ROM significantly (p < 0.05) in most directions in both cage groups, but did not show any difference between the cage groups. Conclusions: There was no significant difference in immediate stability in any direction between the threaded cylindrical cage and the new design of the rectangular cage with endplate teeth.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [1] Biomechanical evaluation of immediate stability with rectangular versus cylindrical interbody cages in stabilization of the lumbar spine
    Dilip K Sengupta
    SMH Mehdian
    Robert C Mulholland
    John K Webb
    Donna D Ohnmeiss
    BMC Musculoskeletal Disorders, 3
  • [2] Spine update - Lumbar interbody cages
    Weiner, BK
    Fraser, RD
    SPINE, 1998, 23 (05) : 634 - 640
  • [3] The importance of the endplate for interbody cages in the lumbar spine
    Anne Polikeit
    Stephen J. Ferguson
    Lutz P. Nolte
    Tracy E. Orr
    European Spine Journal, 2003, 12 : 556 - 561
  • [4] Biomechanical comparison of anterior versus posterior lumbar threaded interbody fusion cages
    Vishteh, AG
    Crawford, NR
    Chamberlain, RH
    Thramann, JJ
    Park, SC
    Craigo, JB
    Sonntag, VKH
    Dickman, CA
    SPINE, 2005, 30 (03) : 302 - 310
  • [5] The importance of the endplate for interbody cages in the lumbar spine
    Polikeit, A
    Ferguson, SJ
    Nolte, LP
    Orr, TE
    EUROPEAN SPINE JOURNAL, 2003, 12 (06) : 556 - 561
  • [6] A Biomechanical Stability Study of Extraforaminal Lumbar Interbody Fusion on the Cadaveric Lumbar Spine Specimens
    Guo, Song
    Zeng, Cheng
    Yan, Meijun
    Han, Yingchao
    Xia, Dongdong
    Sun, Guixin
    Li, Lijun
    Yang, Mingjie
    Tan, Jun
    PLOS ONE, 2016, 11 (12):
  • [7] Biomechanical comparison of posterior lumbar interbody fusion cages
    Rapoff, AJ
    Ghanayem, AJ
    Zdeblick, TA
    SPINE, 1997, 22 (20) : 2375 - 2379
  • [8] Biomechanical comparison of biodegradable lumbar interbody fusion cages
    Khodadadyan-Klostermann, C
    Kandziora, F
    Schnake, KJ
    Lewandrowski, KU
    Wise, D
    Weiler, A
    Haas, NP
    CHIRURG, 2001, 72 (12): : 1431 - 1438
  • [9] Biomechanical comparison of cervical spine interbody fusion cages
    Kandziora, F
    Pflugmacher, R
    Schäfer, J
    Born, C
    Duda, G
    Haas, NP
    Mittlmeier, T
    SPINE, 2001, 26 (17) : 1850 - 1857
  • [10] Biomechanical analysis of cages for posterior lumbar interbody fusion
    Fantigrossi, Alfonso
    Galbusera, Fabio
    Raimondi, Manuela Teresa
    Sassi, Marco
    Fornari, Maurizio
    MEDICAL ENGINEERING & PHYSICS, 2007, 29 (01) : 101 - 109