Macular Ganglion Cell and Retinal Nerve Fiber Layer Thickness in Children With Refractive Errors-An Optical Coherence Tomography Study

被引:22
|
作者
Goh, Jody P. [1 ]
Koh, Victor [1 ]
Chan, Yiong Huak [2 ]
Ngo, Cheryl [1 ]
机构
[1] Natl Univ Singapore Hosp, Dept Ophthalmol, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore
[2] Natl Univ Singapore, Yong Loo Lin Sch Med, Biostat Unit, Singapore, Singapore
关键词
children; ganglion cell-inner plexiform layer thickness; retinal nerve fiber layer thickness; high definition optical coherence tomography; glaucoma; INNER PLEXIFORM LAYER; REFERENCE RANGES; AXIAL LENGTH; GLAUCOMA; MYOPIA; PARAMETERS;
D O I
10.1097/IJG.0000000000000683
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the distribution of macular ganglion cell-inner plexiform layer (GC-IPL) thickness and peripapillary retinal nerve fiber layer (RNFL) thickness in children with refractive errors. Materials and Methods: Two hundred forty-three healthy eyes from 139 children with refractive error ranging from -10.00 to +5.00D were recruited from the National University Hospital Eye Surgery outpatient clinic. After a comprehensive ocular examination, refraction, and axial length (AL) measurement (IOLMaster), macular GC-IPL and RNFL thickness values were obtained with a spectral domain Cirrus high definition optical coherence tomography system (Carl Zeiss Meditec Inc.). Only scans with signal strength of >6/10 were included. Correlation between variables was calculated using the Pearson correlation coefficient. A multivariate analysis using mixed models was done to adjust for confounders. Results: The mean spherical equivalent refraction was -3.20 +/- 3.51D and mean AL was 24.39 +/- 1.72mm. Average, minimum, superior, and inferior GC- IPL were 82.59 +/- 6.29, 77.17 +/- 9.65, 83.68 +/- 6.96, and 81.64 +/- 6.70 mu m, respectively. Average, superior, and inferior peripapillary RNFL were 99.00 perpendicular to 11.45, 123.20 perpendicular to 25.81, and 124.24 +/- 22.23 mu m, respectively. Average, superior, and inferior GC-IPL were correlated with AL (beta = -2.056, P-value 0.000; beta = -2.383, P- value 0.000; beta = -1.721, P-value 0.000), but minimum GC- IPL was not (beta = -1.056, P-value 0.115). None of the RNFL parameters were correlated with AL. Conclusions: This study establishes normative macular GC- IPL and RNFL thickness in children with refractive errors. Our results suggest that high definition optical coherence tomography RNFL parameters and minimum GC-IPL are not affected by AL or myopia in children, and therefore warrants further evaluation in pediatric glaucoma patients.
引用
收藏
页码:619 / 625
页数:7
相关论文
共 50 条
  • [21] Evaluation of peripapillary retinal nerve fiber layer,macula and ganglion cell thickness in amblyopia using spectral optical coherence tomography
    Penpe Gul Firat
    Ercan Ozsoy
    Soner Demire
    Tongabay Cumurcu
    Abuzer Gunduz
    International Journal of Ophthalmology, 2013, (01) : 90 - 94
  • [22] Evaluation of peripapillary retinal nerve fiber layer, macula and ganglion cell thickness in amblyopia using spectral optical coherence tomography
    Firat, Penpe Gul
    Ozsoy, Ercan
    Demirel, Soner
    Cumurcu, Tongabay
    Gunduz, Abuzer
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (01) : 90 - 94
  • [23] Effect of Refractive Power on the Measurement of Peripapillary Retinal Nerve Fiber Layer Thickness in Cirrus Optical Coherence Tomography
    Lee, E.
    Kim, N.
    Kim, C.
    Byeon, S.
    Kim, S.
    Hong, S.
    Seong, G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [24] Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography
    Malik, A.
    Singh, M.
    Arya, S. K.
    Sood, S.
    Ichhpujani, P.
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2012, 4 (01) : 59 - 63
  • [25] Optical coherence tomography longitudinal retinal nerve fiber layer thickness assessment
    Wollstein, G
    Lin, P
    Hertzmark, E
    Fujimoto, JG
    Schuman, JS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U204 - U204
  • [26] Evaluation of Macular Thickness and Retinal Nerve Fiber Layer by Optical Coherence Tomography in Cases with Strabismic and Anisometropic Amblyopia
    Soyugelen, Gulizar
    Onursever, Nihal
    Ceran, Basak Bostanci
    Can, Izzet
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (05): : 318 - 324
  • [27] Measurement of Retinal Nerve Fiber Layer Thickness and Macular Volume for Glaucoma Detection Using Optical Coherence Tomography
    Tomonari Ojima
    Teruyo Tanabe
    Masanori Hangai
    Saiyuu Yu
    Shiho Morishita
    Nagahisa Yoshimura
    Japanese Journal of Ophthalmology, 2007, 51 : 197 - 203
  • [28] Normative spectral domain optical coherence tomography data on macular and retinal nerve fiber layer thickness in Indians
    Appukuttan, Bindu
    Giridhar, Anantharaman
    Gopalakrishnan, Mahesh
    Sivaprasad, Sobha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (03) : 316 - 321
  • [29] Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Sood, Amit
    Paliwal, Rahul Omprakash
    Mishra, Rishu Yogesh
    GALICIAN MEDICAL JOURNAL, 2021, 28 (04)
  • [30] Measurement of retinal nerve fiber layer thickness and macular volume for glaucoma detection using optical coherence tomography
    Ojima, Tomonari
    Tanabe, Teruyo
    Hangai, Masanori
    Yu, Saiyuu
    Morishita, Shiho
    Yoshimura, Nagahisa
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2007, 51 (03) : 197 - 203