Sequential dilation strategy in stent therapy of the aortic coarctation: A single centre experience

被引:4
|
作者
Heck, Pinar Bambul [1 ]
Fayed, Mohamed [1 ,2 ]
Hager, Alfred [1 ]
Cesna, Sigitas [1 ,3 ]
Georgiev, Stanimir [1 ]
Tanase, Daniel [1 ]
Hoerer, Juergen [1 ,4 ]
Ewert, Peter [1 ]
Eicken, Andreas [1 ]
机构
[1] Tech Univ Munchen TUM, Deutsch Herzzentrum Munchen DHM, Dept Paediat Cardiol & Congenital Heart Dis, Munich, Germany
[2] Zagazig Univ, Fac Med, Dept Paediat, Zagazig, Egypt
[3] Vilnius Univ, Inst Clin Med, Clin Cardiac & Vasc Dis, Vilnius, Lithuania
[4] Ludwig Maximilians Univ Munchen, Div Paediat & Congenital Heart Surg, Univ Hosp, Munich, Germany
关键词
Aortic coarctation; Endovascular stent implantation; NATIVE COARCTATION; SUCCESSFUL REPAIR; FOLLOW-UP; RECOARCTATION; COMPLICATIONS; IMPLANTATION; ADULTS;
D O I
10.1016/j.ijcard.2021.01.038
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In our study, we sought to analyse the mid-term results after interventional aortic coarctation (CoA) stenting with sequential dilation of the stent. Methods: The data of all 218 patients, who are above the age of 6 years and underwent CoA-stent implantation in our hospital, were retrospectively analysed on the rate of re-interventions, complications and arterial hypertension at a follow-up time of 31 months. To avoid any aortic complications, stents were deployed primarily not in full size and a second cardiac catheterisation for further dilatation was scheduled within 6-12 months after the stent implantation. Results: The median peak invasive systolic pressure gradient declined significantly from 26.2 mmHg to 2.7 mmHg after stenting. There was one procedure related death due to an aortic rupture after stent implantation. There were in total 33 (15.1%) procedure-related complications including femoral artery complications, stent fracture and stent dislocation (in 9, 9 and 7 patients, respectively). In 85 patients a re-dilatation and in 25 patients a second stent-implantation was necessary at the first re-intervention. The systolic blood pressure declined significantly from 144 mmHg to 131 mmHg after stenting. The number of patients being normotensive changed from 18% before stenting to 78.5% after stenting with adjusted antihypertensive medication. Conclusion: Aortic stenting is an effective means for CoA treatment. With sequential dilation of the stent, a very low rate of life threatening procedural complications and mortality can be achieved. CoA stenting with proper antihypertensive medications results in better control of blood pressure. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 87
页数:6
相关论文
共 50 条
  • [31] MIDDLE AORTIC SYNDROME IN CHILDREN - SINGLE CENTRE EXPERIENCE
    Antoniewicz, Jolanta
    Brzezinska-Rajszys, Grazyna
    Kalicinski, Piotr
    Kosciesza, Andrzej
    Pedich, Marek
    Daszkowska, Jadwiga
    Grenda, Ryszard
    PEDIATRIC NEPHROLOGY, 2012, 27 (09) : 1737 - 1737
  • [32] Direct aortic approach for TAVI: a single centre experience
    H Amrane
    F Porta
    S Head
    A van Boven
    A Kappetein
    Journal of Cardiothoracic Surgery, 8 (Suppl 1)
  • [33] STABILISE; treatment of aortic dissection, a single Centre experience
    Goran Mitreski
    Damian Flanders
    Julian Maingard
    Domenic Robinson
    Jason Chuen
    George Matalanis
    Siven Seevanayagam
    Hong Kuan Kok
    Dinesh Ranatunga
    Hamed Asadi
    Duncan Mark Brooks
    CVIR Endovascular, 5
  • [34] STABILISE; treatment of aortic dissection, a single Centre experience
    Mitreski, Goran
    Flanders, Damian
    Maingard, Julian
    Robinson, Domenic
    Chuen, Jason
    Matalanis, George
    Seevanayagam, Siven
    Kok, Hong Kuan
    Ranatunga, Dinesh
    Asadi, Hamed
    Brooks, Duncan Mark
    CVIR ENDOVASCULAR, 2022, 5 (01)
  • [35] A single centre experience using aorfix endovascular stent graft
    Narendra, N.
    Lambert, G.
    Rai, H.
    Abrew, C.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 222 - 223
  • [36] Aortic Luminal Remodeling After Intravascular Stent Therapy for Coarctation of the Aorta: Intermediate Results
    Pei, Louise
    Abrahamyan, Lusine
    Sklar, Jaime C.
    Muthuppalaniappan, Annamalar
    Romero, Ricardo Gorocica
    Benson, Lee
    Osten, Mark
    Horlick, Eric M.
    JOURNAL OF INVASIVE CARDIOLOGY, 2023, 35 (09):
  • [37] Balloon aortic valve valvuloplasty as palliative therapy in severe aortic valve stenosis: 10 years experience in a single centre
    Mantovani, F.
    Clavel, M. A.
    Jayme, F.
    Valli, L.
    De Mola, R. M.
    Leuzzi, C.
    Navazio, A.
    Guiducci, V.
    EUROPEAN HEART JOURNAL, 2019, 40 : 512 - 512
  • [38] BALLOON AORTIC VALVE VALVULOPLASTYAS PALLIATIVE THERAPY IN SEVERE AORTIC VALVE STENOSIS: 10 YEARS' EXPERIENCE IN A SINGLE CENTRE
    Mantovani, F.
    Leuzzi, C.
    Valli, L.
    De Mola, R.
    Potenza, A.
    Navazio, A.
    Guiducci, V.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0E) : E52 - E52
  • [39] Sequential Therapy In Children: Single Center Experience
    Salcioglu, Z.
    Sen, H. Sayilan
    Tugcu, D.
    Aydogan, G.
    Akici, F.
    Keskindemirci, G.
    Gokce, M.
    Bayram, C.
    Baslar, Z.
    HAEMOPHILIA, 2015, 21 : 56 - 56
  • [40] Outcomes following female urethral dilation - a single UK centre's experience
    Moon, A. D.
    Shaw, M.
    Thomas, D.
    Zachariah, K.
    Dorkin, T.
    BJU INTERNATIONAL, 2013, 111 : 55 - 55