DETECTION OF MORPHOLOGIC PATTERNS OF DIABETIC MACULAR EDEMA USING A DEEP LEARNING APPROACH BASED ON OPTICAL COHERENCE TOMOGRAPHY IMAGES

被引:27
|
作者
Wu, Qiaowei [1 ]
Zhang, Bin [2 ]
Hu, Yijun [3 ,4 ]
Liu, Baoyi [1 ]
Cao, Dan [1 ]
Yang, Dawei [1 ,5 ]
Peng, Qingsheng [1 ,5 ]
Zhong, Pingting [1 ,5 ]
Zeng, Xiaomin [1 ]
Xiao, Yu [1 ]
Li, Cong [1 ]
Fang, Ying [1 ]
Feng, Songfu [6 ]
Huang, Manqing [1 ]
Cai, Hongmin [2 ]
Yang, Xiaohong [1 ]
Yu, Honghua [1 ]
机构
[1] Southern Med Univ, Guangdong Eye Inst, Dept Ophthalmol,Sch Clin Med 2, Guangdong Prov Peoples Hosp,Guangdong Acad Med Sc, Guangzhou, Peoples R China
[2] South China Univ Technol, Sch Comp Sci & Engn, Guangzhou, Peoples R China
[3] Guangzhou Aier Eye Hosp, Refract Surg Ctr, Aier Inst Refract Surg, Guangzhou, Peoples R China
[4] Cent South Univ, Aier Sch Ophthalmol, Changsha, Peoples R China
[5] Shantou Univ, Med Coll, Shantou, Peoples R China
[6] Southern Med Univ, Dept Ophthalmol, Zhujiang Hosp, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
artificial intelligence; deep learning; complication of diabetic retinopathy; diabetic macular edema; optical coherence tomography; BLOOD-RETINAL BARRIER; SYSTEMIC RISK-FACTORS; INTRAVITREAL BEVACIZUMAB; OUTCOMES; PATHOPHYSIOLOGY; RETINOPATHY; DISEASES;
D O I
10.1097/IAE.0000000000002992
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To develop a deep learning (DL) model to detect morphologic patterns of diabetic macular edema (DME) based on optical coherence tomography (OCT) images. Methods: In the training set, 12,365 OCT images were extracted from a public data set and an ophthalmic center. A total of 656 OCT images were extracted from another ophthalmic center for external validation. The presence or absence of three OCT patterns of DME, including diffused retinal thickening, cystoid macular edema, and serous retinal detachment, was labeled with 1 or 0, respectively. A DL model was trained to detect three OCT patterns of DME. The occlusion test was applied for the visualization of the DL model. Results: Applying 5-fold cross-validation method in internal validation, the area under the receiver operating characteristic curve for the detection of three OCT patterns (i.e., diffused retinal thickening, cystoid macular edema, and serous retinal detachment) was 0.971, 0.974, and 0.994, respectively, with an accuracy of 93.0%, 95.1%, and 98.8%, respectively, a sensitivity of 93.5%, 94.5%, and 96.7%, respectively, and a specificity of 92.3%, 95.6%, and 99.3%, respectively. In external validation, the area under the receiver operating characteristic curve was 0.970, 0.997, and 0.997, respectively, with an accuracy of 90.2%, 95.4%, and 95.9%, respectively, a sensitivity of 80.1%, 93.4%, and 94.9%, respectively, and a specificity of 97.6%, 97.2%, and 96.5%, respectively. The occlusion test showed that the DL model could successfully identify the pathologic regions most critical for detection. Conclusion: Our DL model demonstrated high accuracy and transparency in the detection of OCT patterns of DME. These results emphasized the potential of artificial intelligence in assisting clinical decision-making processes in patients with DME.
引用
收藏
页码:1110 / 1117
页数:8
相关论文
共 50 条
  • [41] Optical Coherence Tomography Imaging for Diabetic Retinopathy and Macular Edema
    John C. BuAbbud
    Motasem M. Al-latayfeh
    Jennifer K. Sun
    Current Diabetes Reports, 2010, 10 : 264 - 269
  • [42] Deep learning based early stage diabetic retinopathy detection using optical coherence tomography
    Li, Xuechen
    Shen, Linlin
    Shen, Meixiao
    Tan, Fan
    Qiu, Connor S.
    NEUROCOMPUTING, 2019, 369 : 134 - 144
  • [43] Optical Coherence Tomography Imaging for Diabetic Retinopathy and Macular Edema
    BuAbbud, John C.
    Al-latayfeh, Motasem M.
    Sun, Jennifer K.
    CURRENT DIABETES REPORTS, 2010, 10 (04) : 264 - 269
  • [44] Spectral Domain Optical Coherence Tomography in Diabetic Macular Edema
    Pournaras, Jean-Antoine C.
    Erginay, Ali
    Lazrak, Zineb
    Gaudric, Alain
    Massin, Pascale
    OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (06) : 548 - 553
  • [45] Quantitative assessment of diabetic macular edema with optical coherence tomography
    Hee, MR
    Puliafito, CA
    Duker, JS
    Reichel, E
    Coker, JG
    Wilkins, JR
    Schuman, JS
    Swanson, EA
    Fujimoto, JG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 4377 - 4377
  • [46] Visual correlations of optical coherence tomography of diabetic macular edema
    Kim, BY
    Kaiser, PK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [47] ROLE OF OPTICAL COHERENCE TOMOGRAPHY IN DIABETIC MACULAR EDEMA SCREENING
    Palarie, N.
    Pasenco, T. V.
    Vudu, L. T.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (03) : E118 - E118
  • [48] Optical coherence tomography classification of diabetic cystoid macular edema
    Helmy, Yasser M.
    Allah, Heba R. Atta
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 1731 - 1737
  • [49] Automatic Identification of Macular Edema in Optical Coherence Tomography Images
    Samagaio, Gabriela
    Estevez, Aida
    de Moura, Joaquim
    Novo, Jorge
    Ortega, Marcos
    Isabel Fernandez, Maria
    VISAPP: PROCEEDINGS OF THE 13TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER VISION, IMAGING AND COMPUTER GRAPHICS THEORY AND APPLICATIONS - VOL 4: VISAPP, 2018, : 533 - 540
  • [50] Structure tensor based automated detection of macular edema and central serous retinopathy using optical coherence tomography images
    Hassan, Bilal
    Raja, Gulistan
    Hassan, Taimur
    Akram, M. Usman
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2016, 33 (04) : 455 - 463