Accelerated intensity-modulated radiotherapy to breast in prone position: Dosimetric results

被引:41
|
作者
DeWyngaert, J. Keith [1 ]
Jozsef, Gabor [1 ]
Mitchell, James [1 ]
Rosenstein, Barry [1 ]
Formenti, Silvia C. [1 ]
机构
[1] NYU, Sch Med, Dept Radiat Oncol, New York, NY 10016 USA
关键词
prone breast irradiation; intensity-modulated radiotherapy; IMRT; accelerated regimen; simultaneous integrated boost; SIB;
D O I
10.1016/j.ijrobp.2007.04.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To report the physics and dosimetry results of a trial of accelerated intensity-modulated radiotherapy to the whole breast with a concomitant boost to the tumor bed in patients treated in the prone position. Methods and Materials: Patients underwent computed tomography planning and treatment in the prone position on a dedicated treatment platform. The platform has an open aperture on the side to allow for the index breast to fall away from the chest wall. Noncontrast computed tomography images were acquired at 2.5- or 3.75-mm-thick intervals, from the level of the mandible to below the diaphragm. A dose of 40.5 Gy was delivered to the entire breast at 2.7-Gy fractions in 15 fractions. An additional dose of 0.5 Gy was delivered as a concomitant boost to the lumpectomy site, with a 1-cm margin, using inverse planning, for a total dose of 48 Gy in 15 fractions. No more than 10% of the heart and lung volume was allowed to receive >18 and >20 Gy, respectively. Results: Between September 2003 and August 2005, 91 patients were enrolled in the study. The median volume of heart that received >= 18 Gy was 0.5%, with a maximal value of 4.7%. The median volume of ipsilateral lung that received >= 20 Gy was 0.8%, with a maximum of 7.2%. Conclusion: This technique for whole breast radiotherapy is feasible and enables an accelerated regimen in the prone position while sparing the lung and heart. (C) 2007 Elsevier Inc.
引用
收藏
页码:1251 / 1259
页数:9
相关论文
共 50 条
  • [11] Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
    Koksal, C.
    Kesen, N. D.
    Akbas, U.
    Kalafat, U.
    Ozkaya, K.
    Okutan, M.
    Fayda, E. M.
    Kucucuk, S.
    Bilge, H.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2017, 15 (04): : 353 - 362
  • [12] A comparison of supine intensity-modulated radiotherapy treatment with prone 3D conformal radiotherapy for rectal cancer: Preliminary results of dosimetric analysis
    Usiene, I.
    Andrade, R. S.
    Heron, D. E.
    McCoy, C.
    Mohney, M. M.
    Smith, R. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S296 - S297
  • [13] PREDICTORS FOR CLINICAL OUTCOMES AFTER ACCELERATED PARTIAL BREAST INTENSITY-MODULATED RADIOTHERAPY
    Reeder, Reed
    Carter, Dennis L.
    Howell, Kathryn
    Henkenberns, Phyllis
    Tallhamer, Michael
    Johnson, Tim
    Kercher, Jane
    Widner, Jodi
    Kaske, Terese
    Paul, Devchand
    Sedlacek, Scot
    Leonard, Charles E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01): : 92 - 97
  • [14] Prone position breast irradiation;: an intensity modulated radiotherapy (IMRT) planning study
    Bijker, N.
    van Heumen, M.
    Alberding, F.
    van Vliet-Vroegindeweij, C.
    Minkema, D.
    Wittkamper, F. W.
    Russell, N. S.
    EJC SUPPLEMENTS, 2007, 5 (04): : 195 - 195
  • [15] Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer
    Ercan, Tuelay
    Igdem, Sefik
    Alco, Guel
    Zengin, Funda
    Atilla, Selin
    Dincer, Maktav
    Okkan, Sait
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (04) : 283 - 289
  • [16] Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer
    Tülay Ercan
    Şefik İğdem
    Gül Alço
    Funda Zengin
    Selin Atilla
    Maktav Dinçer
    Sait Okkan
    Japanese Journal of Radiology, 2010, 28 : 283 - 289
  • [17] BENCHMARKING DOSIMETRIC QUALITY ASSESSMENT OF PROSTATE INTENSITY-MODULATED RADIOTHERAPY
    Senthi, Sashendra
    Gill, Suki S.
    Haworth, Annette
    Kron, Tomas
    Cramb, Jim
    Rolfo, Aldo
    Thomas, Jessica
    Duchesne, Gillian M.
    Hamilton, Christopher H.
    Joon, Daryl Lim
    Bowden, Patrick
    Foroudi, Farshad
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02): : 998 - 1005
  • [18] Accelerated Partial Breast Irradiation with Intensity-Modulated Radiotherapy Is Feasible for Chinese Breast Cancer Patients
    He, Zhenyu
    Wu, Sangang
    Zhou, Juan
    Li, Fengyan
    Sun, Jiayan
    Lin, Qin
    Lin, Huanxin
    Guan, Xunxing
    JOURNAL OF BREAST CANCER, 2014, 17 (03) : 256 - 264
  • [19] Accelerated Partial Breast Intensity-Modulated Radiotherapy in Women Who Have Prior Breast Augmentation
    Leonard, Charles E.
    Johnson, Tim
    Tallhamer, Michael
    Howell, Kathryn
    Kercher, Jane
    Kaske, Terese
    Barke, Lora
    Sedlacek, Scot
    Hobart, Tracy
    Carter, Dennis L.
    CLINICAL BREAST CANCER, 2011, 11 (03) : 184 - 190
  • [20] Dosimetric comparison of intensity-modulated and 3D conformal accelerated partial breast irradiation
    Stelczer, G.
    Meszaros, N.
    Pesznyak, C.
    Major, T.
    Polgar, C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S191 - S192