Hemiepiphysiodesis for Idiopathic Genu Valgum: Percutaneous Transphyseal Screw Versus Tension-band Plate

被引:24
|
作者
Park, Hoon [1 ]
Park, Minjung [3 ]
Kim, Sung Min [1 ,2 ]
Kim, Hyun Woo
Lee, Dong Hoon [2 ]
机构
[1] Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Orthopaed Surg, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Severance Childrens Hosp, Div Orthopaed Surg, 50 Yonsei Ro, Seoul 03722, South Korea
[3] Natl Hlth Insurance Serv Ilsan Hosp, Dept Orthopaed Surg, Goyang, South Korea
关键词
hemiepiphysiodesis; transphyseal screw; tension-band plate; genu valgum; ANGULAR DEFORMITY CORRECTION; MEDIAL MALLEOLAR SCREW; GUIDED GROWTH; ANKLE VALGUS; TEMPORARY HEMIEPIPHYSIODESIS; KNEE; EPIPHYSIODESIS; CHILDREN; 8-PLATE; LENGTH;
D O I
10.1097/BPO.0000000000000821
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background:The aim of this study was to compare the outcomes of angular deformity correction by percutaneous hemiepiphysiodesis using transphyseal screw (PETS) or tension-band plating (TBP) in growing children with idiopathic genu valgum with emphasis on the rate of deformity correction.Methods:We retrospectively reviewed cases of hemiepiphysiodesis for angular deformity in lower extremities between 2009 and 2014. A total of 90 limbs in 33 patients received PETS and 60 limbs in 24 patients received TBP. Angular measurements were compared preoperatively and at the time of hardware removal. The amount and rate of angular deformity correction were compared between the 2 groups. Potential factors affecting correction velocity were investigated using multivariate analysis.Results:Angular correction was achieved in all patients. The mean rate of correction was more rapid with PETS than with TBP at both the distal femur (0.92 vs. 0.64 deg./mo, respectively; P<0.001) and proximal tibia (0.72 vs. 0.55 deg./mo, respectively; P=0.019). Multivariate analysis showed that the used implant significantly affected the rate of correction: PETS demonstrated faster correction velocity than TBP (-0.26, 95% confidence interval, -0.35 to -0.17, P<0.001).Conclusions:Both PETS and TBP techniques result in satisfactory correction of coronal angular deformity in patients with idiopathic genu valgum. However, the observed rate of correction was faster with PETS than TBP. Correction with PETS, rather than TBP, may better serve patients near skeletal maturity.Level of Evidence:Level IIIretrospective comparative series.
引用
收藏
页码:325 / 330
页数:6
相关论文
共 50 条
  • [31] Percutaneous medial hemi-epiphysiodesis using a transphyseal screw for caput valgum associated with developmental dysplasia of the hip
    Chang Ho Shin
    Wan Kee Hong
    Doo Jae Lee
    Won Joon Yoo
    In Ho Choi
    Tae-Joon Cho
    BMC Musculoskeletal Disorders, 18
  • [32] Percutaneous medial hemi-epiphysiodesis using a transphyseal screw for caput valgum associated with developmental dysplasia of the hip
    Shin, Chang Ho
    Hong, Wan Kee
    Lee, Doo Jae
    Yoo, Won Joon
    Choi, In Ho
    Cho, Tae-Joon
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [33] A comparison between a hinged plate and screw system and a conventional tension-band plate and screw system used for correction of an angular deformity of the lower limb: an animal study
    Zhenkai Wu
    Dahang Zhao
    Li Zhao
    Jianlin Liu
    Hai Li
    Jie Zhu
    Fengcang Ma
    Daniel Edward Porter
    Journal of Orthopaedic Surgery and Research, 10
  • [34] A comparison between a hinged plate and screw system and a conventional tension-band plate and screw system used for correction of an angular deformity of the lower limb: an animal study
    Wu, Zhenkai
    Zhao, Dahang
    Zhao, Li
    Liu, Jianlin
    Li, Hai
    Zhu, Jie
    Ma, Fengcang
    Porter, Daniel Edward
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [35] Guided growth using a tension-band plate in Blount's disease
    Mare, Pieter Herman
    Thompson, David Mungo
    Marais, Leonard Charles
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2022, 31 (02): : 120 - 126
  • [36] TENSION-BAND WIRING AND LAG SCREW FIXATION OF A TRANSVERSE, COMMINUTED FRACTURE OF A PATELLA IN A HORSE
    HUNT, RJ
    BAXTER, GM
    ZAMOS, DT
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1992, 200 (06) : 819 - 820
  • [37] Risk Factors for Rebound After Correction of Genu Valgum in Skeletal Dysplasia Patients Treated by Tension Band Plates
    Ulusaloglu, Armagan C.
    Asma, Ali
    Rogers, Kenneth J.
    Thacker, Mihir M.
    Mackenzie, William G. S.
    Mackenzie, William G.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2022, 42 (04) : 190 - 194
  • [38] Comparison of double screw fixation versus tension-band fixation after olecranon osteotomy for complex distal humerus fractures
    Dumartinet-Gibaud, Raphaelle
    Lancigu, Romain
    Hermine, Pierre De Sainte
    Cronier, Patrick
    Hubert, Laurent
    Rony, Louis
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (02)
  • [39] The efficacy of hemiepiphysiodesis for idiopathic knee coronal angular deformity by reconstruction plate and screw: A pilot study
    Maleki, Arash
    Qoreishi, Mohamad
    Bisadi, Amir
    Safdari, Farshad
    Daei Sorkhabi, Amin
    Fotouhi, Ali
    Tahririan, Mohammad A. A.
    HEALTH SCIENCE REPORTS, 2023, 6 (06)
  • [40] The 8-plate versus physeal stapling for temporary hemiepiphyseodesis correcting genu valgum and genu varum: a retrospective analysis of thirty five patients
    Eva Maria Jelinek
    Bernd Bittersohl
    Friederike Martiny
    Axel Scharfstädt
    Rüdiger Krauspe
    Bettina Westhoff
    International Orthopaedics, 2012, 36 : 599 - 605