Comparing Deep Sclerectomy With Collagen Implant to the New Method of Very Deep Sclerectomy With Collagen Implant A Single-masked Randomized Controlled Trial

被引:15
|
作者
Mansouri, Kaweh [1 ]
Tran, Hoai Viet [1 ]
Ravinet, Emilie [1 ]
Mermoud, Andre [1 ]
机构
[1] Univ Lausanne, Jules Gonin Eye Hosp, Dept Ophthalmol, CH-1004 Lausanne, Switzerland
关键词
deep sclerectomy; collagen implant; uveoscleral outflow; randomized controlled trial; ULTRASOUND BIOMICROSCOPY; NONPENETRATING TRABECULECTOMY; EYES;
D O I
10.1097/IJG.0b013e3181a2fa46
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To prospectively study the intraocular pressure (IOP) lowering effect and safety of the new method of very deep sclerectomy with collagen implant (VDSCI) compared with standard deep sclerectomy with collagen implant (DSCI). Methods: The trial involved 50 eyes of 48 patients with medically uncontrolled primary and secondary open-angle glaucoma, randomized to undergo either VDSCI procedure (25 eyes) or DSCI procedure (25 eyes). Follow-up examinations were performed before surgery and after Surgery at day 1, at week 1, at months 1, 2, 3, 6, 9, 12, 18, and 24 months. Ultrasound biornicroscopy was performed at 3 and 12 months. Results: Mean follow-up period was 18.6 +/- 5.9 (VDSCI) and 18.9 +/- 3.6 (DSCI) months (P = NS). Mean preoperative IOP was 22.4 +/- 7.4 mm Hg for VDSCI and 20.4 +/- 4.4 mm Hg for DSCI eves (P = NS). Mean postoperative IOP was 3.9 +/- 2.3 (VDSCI) and 6.3 +/- 4.3 (DSCI) (P < 0.05) at day 1, and 12.2 +/- 3.9 (VDSCI) and 13.3 +/- 3.4 (DSCI) (P = NS) at month 24. At the last visit, the complete success rate (defined as an IOP of <= 18 mm Hg and a percentage drop of at least 20%, achieved without medication) was 57% in VDSCI and 62% in DSCI eves (P = NS) ultrasound biomicroscopy at 12 months showed a mean volume of the subconjunctival filtering bleb of 3.9 +/- 4.2 mm(3) (VDSCI) and 6.8 +/- 7.5 mm(3) (DSCI) (P = 0.426) and 5.2 +/- 3.6 mm(3) (VDSCI) and 5.4 +/- 2.9 mm(3) (DSCI) (P = 0.902) for the intrascleral space. Conclusions: Very deep sclerectomy seems to provide stable and good control of IOP at 2 years of follow-up with few postoperative complications similar to standard deep sclerectomy with the collagen implant.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [31] Deep sclerectomy with two different designs of collagen implant in an animal model: Final results
    Nguyen, C
    Boldea, R
    Roy, S
    Shaarawy, T
    Mermoud, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U225 - U225
  • [32] Aqueous dynamic and histological findings after deep sclerectomy with collagen implant in an animal model
    Delarive, T
    Rossier, A
    Rossier, S
    Ravinet, E
    Shaarawy, T
    Mermoud, A
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (11) : 1340 - 1344
  • [33] Deep sclerectomy in one eye versus Deep Sclerectomy with Collagen Implant in the contralateral eye of the same patient: Long term follow-up
    Shaarawy, TM
    Schnyder, C
    Mermoud, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U189 - U189
  • [34] Deep sclerectomy in one eye vs deep sclerectomy with collagen implant in the contralateral eye of the same patient: long-term follow-up
    T Shaarawy
    A Mermoud
    Eye, 2005, 19 : 298 - 302
  • [35] Deep sclerectomy in one eye vs deep sclerectomy with collagen implant in the contralateral eye of the same patient:: long-term follow-up
    Shaarawy, T
    Mermoud, A
    EYE, 2005, 19 (03) : 298 - 302
  • [36] Deep sclerectomy with collagen implant in one eye compared with trabeculectomy in the other eye of the same patient
    Ambresin, A
    Shaarawy, T
    Mermoud, A
    JOURNAL OF GLAUCOMA, 2002, 11 (03) : 214 - 220
  • [37] Outflow mechanisms after deep sclerectomy with two different designs of collagen implant in an animal model
    Nguyen, Christophe
    Boldea, Radu Christian
    Roy, Sylvain
    Shaarawy, Tarek
    Uffer, Sylvie
    Mermoud, Andre
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (12) : 1659 - 1667
  • [38] Ultrasound biomicroscopy images: long-term results after deep sclerectomy with collagen implant
    Dida Kazakova
    Sigrid Roters
    Corinne C. Schnyder
    Farid Achache
    Christian Jonescu-Cuypers
    André Mermoud
    Günter Krieglstein
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 918 - 923
  • [39] Ultrasound biomicroscopy images: long-term results after deep sclerectomy with collagen implant
    Kazakova, D
    Roters, S
    Schnyder, CC
    Achache, F
    Jonescu-Cuypers, C
    Mermoud, A
    Kriegistein, G
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 240 (11) : 918 - 923
  • [40] Post-operative inflammation following deep sclerectomy with collagen implant versus standard trabeculectomy
    Chiou, AGY
    Mermoud, A
    Jewelewicz, DA
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1998, 236 (08) : 593 - 596