A Rapid and Low-Cost Lung Function Testing Method Based on an Optical Flow Sensor

被引:1
|
作者
Hoeglinger, Markus [1 ]
Wiesmayr, Bianca [2 ]
Baumgartner, Werner [1 ]
Stadler, Anna T. [1 ]
机构
[1] Johannes Kepler Univ Linz, Inst Biomed Mechatron, Altenberger Str 69, A-4040 Linz, Austria
[2] Johannes Kepler Univ Linz, LIT Cyber Phys Syst Lab, Altenberger Str 69, A-4040 Linz, Austria
来源
VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING | 2020年 / 75卷
关键词
Rapid lung function testing; Optical measurement principle; FEV1/FVC ratio; POLYDIMETHYLSILOXANE PDMS;
D O I
10.1007/978-3-030-30648-9_61
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Chronic obstructive pulmonary disease was the fifth highest cause of death in 2002 and it is projected to be the fourth highest cause of mortality by 2030 [1]. It is a heterogeneous disease, but the basic abnormality in all patients is airflow limitation, a value that could be easily assessed by pulmonary function tests. These tests are not readily available in low and middle income countries. Reasons include high equipment costs and the need for trained personnel. In this work, we present a lung function test that measures three highly relevant values: the forced vital capacity; the forced expiratory volume in one second and their ratio; the Tiffeneau-Pinelli index. The sensor is based on an optical detection principle. Light is coupled into a silicone fiber, that consists of a core and a cladding with low refractive index contrast to ensure high bending sensitivity. All parts of the sensor are low-cost, the silicone fiber can be both disposed and autoclaved.
引用
收藏
页码:469 / 477
页数:9
相关论文
共 50 条
  • [11] Low-cost optical cavity based sensor with a large dynamic range
    Rho, D.
    Kim, S.
    OPTICS EXPRESS, 2017, 25 (10): : 11244 - 11253
  • [12] Development of a low-cost pH sensor based on plastic optical fibers
    Rovati, Luigi
    Fabbri, Paola
    Pilati, Francesco
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1615 - +
  • [13] Design and Development of a Low-Cost Cantilever-Based Flow Sensor
    Naveen, Harija
    Narasimhan, Shankar
    George, Boby
    Tangirala, Arun K.
    IFAC PAPERSONLINE, 2020, 53 (01): : 111 - 116
  • [14] Low-cost robust polymer optical fiber temperature sensor based on FIR method for in situ measurement
    Xi'an Institute of Optics and Precision Mechanics of Chinese Academy of Sciences, Xi'an
    710119, China
    不详
    100049, China
    不详
    710069, China
    Guangzi Xuebao, 4
  • [15] LOW-COST OPTICAL SENSOR OVERCOMES AMBIENT LIGHT
    MORTENSEN, HH
    ELECTRONICS, 1975, 48 (12): : 124 - 125
  • [16] A Low-Cost Optical Sensor for Noncontact Vibration Measurements
    Perrone, Guido
    Vallan, Alberto
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (05) : 1650 - 1656
  • [17] Optical Characterization Studies of a Low-Cost Particle Sensor
    Li, Jiayu
    Biswas, Pratim
    AEROSOL AND AIR QUALITY RESEARCH, 2017, 17 (07) : 1691 - 1704
  • [18] Design and Development of a Low-Cost Optical Current Sensor
    Zubia, Joseba
    Casado, Luciano
    Aldabaldetreku, Gotzon
    Montero, Alfonso
    Zubia, Eneko
    Durana, Gaizka
    SENSORS, 2013, 13 (10): : 13584 - 13595
  • [19] Clinical Validation of Innovative Optical-Sensor-Based, Low-Cost, Rapid Diagnostic Test to Reduce Antimicrobial Resistance
    Kapur, Suman
    Gehani, Manish
    Kammili, Nagamani
    Bhardwaj, Pankaj
    Nag, Vijayalakshmi
    Devara, Sudha M.
    Sharad, Shashwat
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (12)
  • [20] A Rapid and Low-Cost Nonlithographic Method to Fabricate Biomedical Microdevices for Blood Flow Analysis
    Pinto, Elmano
    Faustino, Vera
    Rodrigues, Raquel O.
    Pinho, Diana
    Garcia, Valdemar
    Miranda, Joao M.
    Lima, Rui
    MICROMACHINES, 2015, 6 (01): : 121 - 135