Detection and validated quantification of toxic alkaloids in human blood plasma - comparison of LC-APCI-MS with LC-ESI-MS/MS

被引:93
|
作者
Beyer, Jochen
Peters, Frank T.
Kraemer, Thomas
Maurer, Hans H. [1 ]
机构
[1] Univ Saarland, Dept Expt & Clin Toxicol, Inst Expt & Clin Pharmacol & Toxicol, D-66421 Homburg, Germany
[2] Univ Saarland, Inst Legal Med, D-66421 Homburg, Germany
来源
JOURNAL OF MASS SPECTROMETRY | 2007年 / 42卷 / 05期
关键词
LC-MS; LC-MS/MS; determination; alkaloids; plasma;
D O I
10.1002/jms.1191
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Poisonings with toxic plants may occur after abuse, intentional or accidental ingestion of plants. For diagnosis of such poisonings, multianalyte procedures were developed for detection and validated quantification of the toxic alkaloids aconitine, atropine, colchicine, coniine, cytisine, nicotine and its metabolite cotinine, physostigmine, and scopolamine in plasma using LC-APCI-MS and LC-ESI-MS/MS. After mixed-mode solid-phase extraction of 1 ml of plasma, the analytes were separated using a C8 base select separation column and gradient elution (acetonitrile/ammonium formate, pH 3.5). Calibration curves were used for quantification with cotinine-d(3), benzoylecgonine-d(3), and trimipramine-d(3) as internal standards. The method was validated according to international guidelines. Both assays were selective for the tested compounds. No instability was observed after repeated freezing and thawing or in processed samples. The assays were linear for coniine, cytisine, nicotine and its metabolite cotinine, from 50 to 1000 ng/ml using LC-APCI-MS and 1 to 1000 ng/ml using LC-ESI-MS/MS, respectively, and for aconitine, atropine, colchicine, physostigmine, and scopolamine from 5 to 100 ng/ml for LC-APCI-MS and 0.1 to 100 ng/ml for LC-ESI-MS/MS, respectively. Accuracy ranged from -38.6 to 14.0%, repeatability from 2.5 to 13.5%, and intermediate precision from 4.8 to 13.5% using LC-APCI-MS and from -38.3 to 8.3% for accuracy, from 3.5 to 13.8%, for repeatability, and from 4.3 to 14.7% for intermediate precision using LC-ESI-MS/MS. The lower limit of quantification was fixed at the lowest calibrator in the linearity experiments. With the exception of the greater sensitivity and higher identification power, LC-ESI-MS/MS had no major advantages over LC-APCI-MS. Both presented assays were applicable for sensitive detection of all studied analytes and for accurate and precise quantification, with the exception of the rather volatile nicotine. The applicability of the assays was demonstrated by analysis of plasma samples from suspected poisoning cases. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:621 / 633
页数:13
相关论文
共 50 条
  • [31] LC-ESI-MS/MS determination of paclitaxel on dried blood spots
    Rao, R. Nageswara
    Raju, S. Satyanarayana
    Vali, R. Mastan
    Sarma, V. U. M.
    Sankar, G. Girija
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (05) : 616 - 621
  • [32] LC-ESI-MS/MS quantification of 4β-hydroxycholesterol and cholesterol in plasma samples of limited volume
    Xu, Yaodong
    Yuan, Yang
    Smith, Lisa
    Edom, Rick
    Weng, Naidong
    Mamidi, Rao
    Silva, Jose
    Evans, David C.
    Lim, Heng-Keang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 85 : 145 - 154
  • [33] Identification of 48 homologues of phosphatidylethanol in blood by LC-ESI-MS/MS
    Gnann, H.
    Engelmann, C.
    Skopp, G.
    Winkler, M.
    Auwaerter, V.
    Dresen, S.
    Ferreiros, N.
    Wurst, F. M.
    Weinmann, W.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (07) : 2415 - 2423
  • [34] Simultaneous quantification of vinblastine and desacetylvinblastine concentrations in canine plasma and urine samples using LC-APCI-MS/MS
    Achanta, Satyanarayana
    Ngo, Minh
    Veitenheimer, Allison
    Maxwell, Lara K.
    Wagner, Jarrad R.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 913 : 147 - 154
  • [35] LC-ESI-MS Method for the Determination of Mizolastine in Human Plasma
    Li Ding
    Yan Zhong
    Qinxin Song
    Li Li
    Lin Yang
    Aidong Wen
    Chromatographia, 2007, 66 : 179 - 184
  • [36] Determination of Tiopronin in Human Plasma and Pharmacokinetics by LC-ESI-MS
    Bin Wang
    Liang Zhao
    Hui Wang
    Yindi Zhang
    Guoqing Zhang
    Chromatographia, 2009, 70 : 89 - 94
  • [37] Determination of glycyrrhetic acid in human plasma by LC-ESI-MS
    Ding, L
    Huang, X
    Yang, J
    Bian, XJ
    Zhang, ZX
    Liu, GY
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (03) : 758 - 762
  • [38] Determination of oxomemazine in human plasma by capillary LC-ESI-MS
    Saber, A. L.
    Elmosallamy, M. A. F.
    Wilson, S. R.
    Lundanes, E.
    Greibrokk, T.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (03) : 393 - 403
  • [39] LC-ESI-MS method for the determination of bisoprolol in human plasma
    Ding, Li
    Zhou, Xia
    Guo, Xiaofeng
    Song, Qinxin
    He, Jianchang
    Xu, Guili
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (02) : 520 - 525
  • [40] Development and Validation of LC-ESI-MS/MS Method for the Determination of Alfuzosin in Human Plasma
    Moustapha, Moustapha E.
    El Gamal, Rania M.
    Kamal, Mehnaz
    JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (11) : 1327 - 1335