Detection and validated quantification of toxic alkaloids in human blood plasma - comparison of LC-APCI-MS with LC-ESI-MS/MS

被引:93
|
作者
Beyer, Jochen
Peters, Frank T.
Kraemer, Thomas
Maurer, Hans H. [1 ]
机构
[1] Univ Saarland, Dept Expt & Clin Toxicol, Inst Expt & Clin Pharmacol & Toxicol, D-66421 Homburg, Germany
[2] Univ Saarland, Inst Legal Med, D-66421 Homburg, Germany
来源
JOURNAL OF MASS SPECTROMETRY | 2007年 / 42卷 / 05期
关键词
LC-MS; LC-MS/MS; determination; alkaloids; plasma;
D O I
10.1002/jms.1191
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Poisonings with toxic plants may occur after abuse, intentional or accidental ingestion of plants. For diagnosis of such poisonings, multianalyte procedures were developed for detection and validated quantification of the toxic alkaloids aconitine, atropine, colchicine, coniine, cytisine, nicotine and its metabolite cotinine, physostigmine, and scopolamine in plasma using LC-APCI-MS and LC-ESI-MS/MS. After mixed-mode solid-phase extraction of 1 ml of plasma, the analytes were separated using a C8 base select separation column and gradient elution (acetonitrile/ammonium formate, pH 3.5). Calibration curves were used for quantification with cotinine-d(3), benzoylecgonine-d(3), and trimipramine-d(3) as internal standards. The method was validated according to international guidelines. Both assays were selective for the tested compounds. No instability was observed after repeated freezing and thawing or in processed samples. The assays were linear for coniine, cytisine, nicotine and its metabolite cotinine, from 50 to 1000 ng/ml using LC-APCI-MS and 1 to 1000 ng/ml using LC-ESI-MS/MS, respectively, and for aconitine, atropine, colchicine, physostigmine, and scopolamine from 5 to 100 ng/ml for LC-APCI-MS and 0.1 to 100 ng/ml for LC-ESI-MS/MS, respectively. Accuracy ranged from -38.6 to 14.0%, repeatability from 2.5 to 13.5%, and intermediate precision from 4.8 to 13.5% using LC-APCI-MS and from -38.3 to 8.3% for accuracy, from 3.5 to 13.8%, for repeatability, and from 4.3 to 14.7% for intermediate precision using LC-ESI-MS/MS. The lower limit of quantification was fixed at the lowest calibrator in the linearity experiments. With the exception of the greater sensitivity and higher identification power, LC-ESI-MS/MS had no major advantages over LC-APCI-MS. Both presented assays were applicable for sensitive detection of all studied analytes and for accurate and precise quantification, with the exception of the rather volatile nicotine. The applicability of the assays was demonstrated by analysis of plasma samples from suspected poisoning cases. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:621 / 633
页数:13
相关论文
共 50 条
  • [1] LC-ESI-MS/MS Method for the Fosamprenavir Quantification Bioanalytical Method Development and Validation for the Quantification Fosamprenavir in Human Plasma by LC-ESI-MS/MS
    Susmitha, Kondam
    Menaka, Muthukkarupan
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2022, 56 (03) : S599 - S604
  • [2] Methods for the analysis of organophosphorus flame retardants—Comparison of GC-EI-MS, GC-NCI-MS, LC-ESI-MS/MS, and LC-APCI-MS/MS
    Tokumura, Masahiro
    Miyake, Yuichi
    Wang, Qi
    Nakayama, Hayato
    Amagai, Takashi
    Ogo, Sayaka
    Kume, Kazunari
    Kobayashi, Takeshi
    Takasu, Shinji
    Ogawa, Kumiko
    Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, 2018, 53 (05): : 475 - 481
  • [3] Sensitive Analysis of Wilforidine in Human Plasma by LC-APCI-MS/MS
    Meiqiang Cai
    Chenyi Shen
    Micong Jin
    Chromatographia, 2013, 76 : 985 - 991
  • [4] Methods for the analysis of organophosphorus flame retardantsComparison of GC-EI-MS, GC-NCI-MS, LC-ESI-MS/MS, and LC-APCI-MS/MS
    Tokumura, Masahiro
    Miyake, Yuichi
    Wang, Qi
    Nakayama, Hayato
    Amagai, Takashi
    Ogo, Sayaka
    Kume, Kazunari
    Kobayashi, Takeshi
    Takasu, Shinji
    Ogawa, Kumiko
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2018, 53 (05): : 475 - 481
  • [5] Sensitive Analysis of Wilforidine in Human Plasma by LC-APCI-MS/MS
    Cai, Meiqiang
    Shen, Chenyi
    Jin, Micong
    CHROMATOGRAPHIA, 2013, 76 (15-16) : 985 - 991
  • [6] Matrix effect in LC-ESI-MS and LC-APCI-MS with off-line and on-line extraction procedures
    Souverain, S
    Rudaz, S
    Veuthey, JL
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) : 61 - 66
  • [7] Fast and Reliable Determination of Voriconazole in Human Plasma by LC-APCI-MS/MS
    Xiong, Xin
    Duan, Jingli
    Zhai, Suodi
    Wang, Lijue
    Lan, Xi
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2010, 74 (10) : 2151 - 2153
  • [8] LC-APCI-MS/MS Quantification and Topical Bioavailability of Chloroacetamide in Rats
    Kim, Tae Hwan
    Seok, Su Hyun
    Kim, Kyu-Bong
    Shin, Beom Soo
    Lee, Jeong Pyo
    Choi, Yong-Kyu
    Kim, Min Gi
    Kim, Min Kyu
    Kim, Sang Min
    Yoo, Sun Dong
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (07) : 1100 - 1106
  • [9] Quantification of desloratadine in human plasma by LC-ESI-MS/MS and application to a pharmacokinetic study
    Ponnuru, Venkata Suresh
    Challa, B. R.
    Nadendla, Ramararo
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2012, 2 (03) : 180 - 187
  • [10] PICOGRAM LEVEL QUANTIFICATION OF VARENICLINE IN HUMAN PLASMA SAMPLES BY LC-ESI-MS/MS
    Dasari, Praveen Kumar
    Darapaneedi, Srinivasa Rao
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2016, 7 (06):