Modeling and Identification of the Electrohysterographic Volume Conductor by High-Density Electrodes

被引:25
|
作者
Rabotti, Chiara [1 ]
Mischi, Massimo [1 ]
Beulen, Lean [2 ]
Oei, Guid [2 ]
Bergmans, Jan W. M. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Elect Engn, NL-5600 MB Eindhoven, Netherlands
[2] Maxima Med Ctr, Dept Obstet & Gynecol, NL-5500 MB Veldhoven, Netherlands
关键词
Action potential; electrohysterography; high-density (HD) electrodes; parameter estimation; smooth muscle; subcutaneous tissue thickness; volume conductor; ELECTRICAL PROPAGATION; SURFACE EMG; FREQUENCY; MUSCLE; REPRODUCIBILITY; CONTRACTIONS; MYOMETRIUM; PARAMETERS; PRESSURE; PATTERNS;
D O I
10.1109/TBME.2009.2035440
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The surface electrohysterographic (EHG) signal represents the bioelectrical activity that triggers the mechanical contraction of the uterine muscle. Previous work demonstrated the relevance of the EHG signal analysis for fetal and maternal monitoring as well as for prognosis of preterm labor. However, for the introduction in the clinical practice of diagnostic and prognostic EHG techniques, further insights are needed on the properties of the uterine electrical activation and its propagation through biological tissues. An important contribution for studying these phenomena in humans can be provided by mathematical modeling. A five-parameter analytical model of the EHG volume conductor and the cellular action potential (AP) is proposed here and tested on EHG signals recorded by a grid of 64 high-density electrodes. The model parameters are identified by a least-squares optimization method that uses a subset of electrodes. The parameters representing fat and abdominal muscle thickness are also measured by echography. The mean correlation coefficient and standard deviation of the difference between the echographic and EHG estimates were 0.94 and 1.9 mm, respectively. No bias was present. These results suggest that the model provides an accurate description of the EHG AP and the volume conductor, with promising perspectives for future applications.
引用
收藏
页码:519 / 527
页数:9
相关论文
共 50 条
  • [1] Identification of the electrohysterographic volume conductor by high-density electrodes
    Rabotti, Chiara
    Mischi, Massimo
    Gamba, Marco
    Vinken, Maartje
    Oei, Guid
    Bergmans, Jan
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 235 - 238
  • [2] GOLD CONDUCTOR PASTES FOR HIGH-DENSITY CIRCUIT
    KADOTA, S
    SHIBATA, K
    ELECTROCOMPONENT SCIENCE AND TECHNOLOGY, 1981, 9 (01): : 31 - 41
  • [3] ELECTROSTATIC BEST FOR HIGH-DENSITY, VOLUME
    RICHMOND, D
    COMPUTER GRAPHICS WORLD, 1986, 9 (03) : 55 - 56
  • [4] Design of High-Density Electrodes for EEG Acquisition
    Xing, Xiao
    Pei, Weihua
    Wang, Yijun
    Liu, Zhiduo
    Chen, Hongda
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 1295 - 1298
  • [5] Dynamics of conductor heating and evaporation by high-density pulse current
    Vorobev, VS
    ZHURNAL TEKHNICHESKOI FIZIKI, 1996, 66 (01): : 35 - 48
  • [7] MODELING AND SIMULATION OF HIGH-DENSITY PLASMAS
    GRAVES, DB
    WU, HM
    PORTEOUS, RK
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (6B): : 2999 - 3006
  • [8] High-density objects in exomass affect the volume of high-density objects inside the field of view
    Coelho-Silva, Fernanda
    Cascante-Sequeira, Deivi
    Rea, Marcela Tarosso
    Oliveira, Matheus L.
    Freitas, Deborah Queiroz
    Haiter-Neto, Francisco
    de-Azevedo-Vaz, Sergio Lins
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (02) : 153 - 160
  • [9] CONDUCTOR PROPAGATION CIRCUITS FOR HIGH-DENSITY BUBBLE-DOMAIN MEMORIES
    COPELAND, JA
    IEEE TRANSACTIONS ON MAGNETICS, 1972, MAG8 (03) : 378 - &
  • [10] HIGH-DENSITY POLYETHYLENE FOR INSULATION OF FINE-CONDUCTOR CITY CABLE
    YOSHIDA, T
    MATSUI, T
    AZUMA, M
    YANAGISA.K
    PLASTICS & POLYMERS, 1968, 36 (121): : 57 - &