共 50 条
Energy and exergy analyses of an integrated solar heat pump system
被引:62
|作者:
Suleman, F.
[1
]
Dincer, I.
[1
]
Agelin-Chaab, M.
[1
]
机构:
[1] Univ Ontario, Fac Engn & Appl Sci, Inst Technol, Oshawa, ON L1H 7K4, Canada
关键词:
Solar energy;
Exergy;
Energy;
Heat pump;
Efficiency;
D O I:
10.1016/j.applthermaleng.2014.08.006
中图分类号:
O414.1 [热力学];
学科分类号:
摘要:
An integrated solar and heat pump based system for industrial heating is developed in this study. The system comprises heat pump cycle for process heating water and solar energy for another industrial heating process. Comprehensive energy and exergy analyses are performed on the system. These analyses generated some compelling results as expected because of the use of green and environmentally friendly energy sources. The results show that the energy efficiency of the profess is 58% while the exergy efficiency is 75%. Energetic COP of the heat pump cycle is 3.54 whereas the exergy efficiency is 42.5%. Moreover, the energetic COP of the system is 2.97 and the exergy efficiency of the system is 35.7%. In the parametric study, a different variation such as changing the temperature and pressure of the condenser also shows positive results. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:559 / 566
页数:8
相关论文