The effects of changed biomechanical parameters on measurements of intraocular pressure in keratoconus patients

被引:29
|
作者
Bohm, A [1 ]
Kohlhaas, M [1 ]
Lerche, RC [1 ]
Bischoff, B [1 ]
Richard, G [1 ]
机构
[1] Univ Hamburg, Augenklin, D-20246 Hamburg, Germany
来源
OPHTHALMOLOGE | 1997年 / 94卷 / 11期
关键词
keratoconus; intraocular pressure; applanation tonometry; tonometry; biomechanics;
D O I
10.1007/s003470050201
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Keratoconus is associated with changes in the corneal structure, such as defects of Bowman's layer, a decrease of corneal thickness etc. They result in alterations of some of the biomechanical parameters of the cornea, namely, rigidity and elasticity. The present study was performed to examine how impression tonometry and applanation tonometry for determination of intraocular pressure (IOP) are affected by the changed biomechanical parameters associated with keratoconus. Patients and methods: We examined 20 normal subjects (40 eyes) and 17 keratoconus patients (25 eyes). The corneal thickness was measured by ultrasound pachymetry in the corneal center. In the keratoconus patients, an additional measurement was made at the conus peak. The corneal curvature was determined using the TMS keratoscope. The IOP measurements were made with the Schiotz tonometer (10 g). For comparison, additional IOP measurements in the corneal center and, in the keratoconus group, on the conus peak were made with the applanation tonometer. Results: The normal subjects had a central corneal thickness of 548 +/- 30 mu m, compared to 505 +/- 42 mu m in the corneal center and 425 +/- 41 Ccm on the conus peak in keratoconus patients. The average corneal curvature was 43.3 +/- 1.8 D in the normal subjects and 47.8 +/- 4.1 D in keratoconus patients. Applanation tonometry produced results on 11.33 +/- 1.43 mm Hg in the normal group (corneal center) compared to values of 12.00 +/- 2.55 mm Hg (corneal center) and 7.30 +/- 1.95 mm Hg (conus peak) in the keratoconus cohort. The coefficient of rigidity was 0.0236 +/- 0.0026 mu l(-1) in the normal subjects, compared to 0.0173 +/- 0.0050 mu l(-1) in the keratoconus patients. Conclusion: The morphological changes associated with keratoconus may cause tonometry errors.
引用
收藏
页码:771 / 774
页数:4
相关论文
共 50 条
  • [1] The effects of changed biomechanical parameters on measurements of intraocular pressure in keratoconus patientsEinfluß der veränderten Biomechanik*
    Andreas Böhm
    Michael Kohlhaas
    R.-C. Lerche
    Birgit Bischoff
    Gisbert Richard
    Der Ophthalmologe, 1997, 94 : 771 - 774
  • [2] Evaluation of Intraocular Pressure and Other Biomechanical Parameters to Distinguish between Subclinical Keratoconus and Healthy Corneas
    Peris-Martinez, Cristina
    Diez-Ajenjo, Maria Amparo
    Garcia-Domene, Maria Carmen
    Pinazo-Duran, Maria Dolores
    Luque-Cobija, Maria Jose
    del Buey-Sayas, Maria angeles
    Orti-Navarro, Susana
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
  • [3] Wave -score -dependent variation in measurements of intraocular pressure and of ocular biomechanical parameters
    Yuhas, Phillip Thomas
    Mahmoud, Ashraf M.
    Roberts, Cynthia J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [4] Differences of corneal biomechanical parameters for keratoconus patients
    Jansone-Langina, Z.
    Mikelsone, R.
    Gertnere, J.
    CLINICAL BIOPHOTONICS II, 2022, 12146
  • [5] Evaluation of Biomechanically Corrected Intraocular Pressure Measurements in Keratoconus and Forme Fruste Keratoconus
    Nishida, Tomoya
    Kojima, Takashi
    Kataoka, Takahiro
    Isogai, Naoki
    Yoshida, Yoko
    Nakamura, Tomoaki
    OPHTHALMIC RESEARCH, 2020, 63 (06) : 541 - 549
  • [6] Intraocular pressure in keratoconus
    Read, Scott A.
    Collins, Michael J.
    ACTA OPHTHALMOLOGICA, 2011, 89 (04) : 358 - 364
  • [7] Corneal biomechanical parameters and intraocular pressure: the effect of topical anesthesia
    Ogbuehi, Kelechi C.
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 871 - 878
  • [8] Intraoffice variability of corneal biomechanical parameters and intraocular pressure (IOP)
    Gonzalez-Meijome, Jose M.
    Queiros, Antonio
    Jorge, Jorge
    Diaz-Rey, Alberto
    Parafita, Manuel A.
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (06) : 457 - 462
  • [9] Intraocular pressure and biomechanical parameters measured with two generations of dynamic bidirectional air-puff tonometers in subjects with keratoconus and in healthy controls
    Fortman, Maddison Marie
    Mahmoud, Ashraf M.
    Roberts, Cynthia J.
    Yuhas, Phillip Thomas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [10] Corneal Biomechanical Changes in Diabetes Mellitus and Their Influence on Intraocular Pressure Measurements
    Sahin, Afsun
    Bayer, Atilla
    Ozge, Gokhan
    Mumcuoglu, Tarkan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (10) : 4597 - 4604