Utility of computed diffusion-weighted MRI for predicting aggressiveness of prostate cancer

被引:24
|
作者
Waseda, Yuma [1 ]
Yoshida, Soichiro [1 ]
Takahara, Taro [2 ]
Kwee, Thomas Christian [3 ]
Matsuoka, Yoh [1 ]
Saito, Kazutaka [1 ]
Kihara, Kazunori [1 ]
Fujii, Yasuhisa [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch, Urol, Tokyo, Japan
[2] Tokai Univ, Biomed Engn, Sch Engn, Hiratsuka, Kanagawa, Japan
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, Groningen, Netherlands
关键词
biomarkers; diffusion magnetic resonance imaging; Gleason grading; multimodal imaging; prostatic neoplasms; MAGNETIC-RESONANCE; COEFFICIENT VALUES; RADICAL PROSTATECTOMY; TUMOR-DETECTION; T; HISTOLOGIC GRADE; GLEASON SCORE; B VALUE; RATIO; ADC;
D O I
10.1002/jmri.25593
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo investigate the value of computed (c) diffusion-weighted imaging (DWI) in assessing prostate cancer aggressiveness. Materials and MethodsFifty-five patients with peripheral zone prostate cancer who underwent prebiopsy 1.5T magnetic resonance imaging (including native DWI at b-values of 0 and 1000 s/mm(2)) were included. cDWI signal intensities of peripheral zone prostate cancer and nonmalignant prostate tissue were measured. Association between changes in monoexponentially calculated cDWI signals according to different b-values and primary Gleason grades were assessed. ResultsThe cDWI signal intensity of prostate cancer was lower at b=0 s/mm(2) and higher at b=1000 s/mm(2) compared to nonmalignant prostate tissue. The b-value at which the signal intensities of prostate cancer and nonmalignant prostate tissue were equal was defined as the iso-b-value. On multivariate analysis, only the iso-b-value was a significant predictor of primary Gleason grade 4/5 cancer (P=0.001). The area under the curve (AUC) of the iso-b-value for diagnosing primary Gleason grade 4/5 cancer was 0.94, and significantly higher than that of the tumor apparent diffusion coefficient (ADC) value with an AUC of 0.68 (P<0.001). ConclusioncDWI with iso-b-value-based semiquantitative analysis was found to be useful for predicting the aggressiveness of prostate cancer and may potentially outperform tumor ADC measurements in this setting. Level of Evidence: 3 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:490-496
引用
收藏
页码:490 / 496
页数:7
相关论文
共 50 条
  • [41] Monitoring prostate thermal therapy with diffusion-weighted MRI
    Chen, Jing
    Daniel, Bruce L.
    Diederich, Chris J.
    Bouley, Donna M.
    van den Bosch, Maurice A. A. J.
    Kinsey, Adam M.
    Sommer, Graham
    Pauly, Kim Butts
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) : 1365 - 1372
  • [43] LYMPH NODE STAGING USING DIFFUSION-WEIGHTED MRI IN BLADDER OR PROSTATE CANCER
    Thoeny, Harriet C.
    Birkhaeuser, Frederic D.
    Triantafyllou, Maria
    Binser, Tobias
    Fleischmann, Achim
    Froehlich, Johannes M.
    Vermathen, Peter
    Studer, Urs E.
    JOURNAL OF UROLOGY, 2010, 183 (04): : E156 - E156
  • [44] Diffusion-weighted MRI of advanced gastric cancer: correlations of the apparent diffusion coefficient with Borrmann classification, proliferation and aggressiveness
    Ma, Liang
    Guo, Liling
    Zhu, Xuyou
    Yi, Xianghua
    Du, Wenxian
    Lan, Xiucai
    Wang, Peijun
    ABDOMINAL RADIOLOGY, 2025,
  • [45] Diffusion-weighted MRI
    Filippi, M
    Rocca, MA
    NEW FRONTIERS OF MR-BASED TECHNIQUES IN MULTIPLE SCLEROSIS, 2003, : 33 - 45
  • [46] Diffusion-weighted MRI in head and neck cancer
    Hermans, Robert
    CURRENT OPINION IN OTOLARYNGOLOGY & HEAD AND NECK SURGERY, 2010, 18 (02): : 72 - 78
  • [47] DIFFUSION-WEIGHTED MRI IN HEAD AND NECK CANCER
    Hermans, R.
    Vandecaveye, V.
    JBR-BTR, 2007, 90 (04): : 264 - 267
  • [48] Feasibility Study of Synthetic Diffusion-Weighted MRI in Patients with Breast Cancer in Comparison with Conventional Diffusion-Weighted MRI
    Choi, Bo Hwa
    Baek, Hye Jin
    Ha, Ji Young
    Ryu, Kyeong Hwa
    Moon, Jin Il
    Park, Sung Eun
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Jung, Eun Jung
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (09) : 1036 - 1044
  • [49] Intraprocedural Diffusion-weighted Imaging for Predicting Ablation Zone during MRI-guided Focused Ultrasound of Prostate Cancer
    Bitton, Rachel R.
    Shao, Wei
    Chodakeiwitz, Yosef
    Brunsing, Ryan L.
    Sonn, Geoffery
    Rusu, Mirabela
    Ghanouni, Pejman
    RADIOLOGY-IMAGING CANCER, 2024, 6 (05):
  • [50] Computed Diffusion-Weighted Imaging in Prostate Cancer: Basics, Advantages, Cautions, and Future Prospects
    Ueno, Yoshiko R.
    Tamada, Tsutomu
    Takahashi, Satoru
    Tanaka, Utaru
    Sofue, Keitaro
    Kanda, Tomonori
    Nogami, Munenobu
    Ohno, Yoshiharu
    Hinata, Nobuyuki
    Fujisawa, Masato
    Murakami, Takamichi