Research on Low-voltage Ride-through Technology of Doubly-fed VSCF Wind Power Generation System

被引:0
|
作者
Bao Wei [1 ]
Yin Zhongdong [1 ]
机构
[1] N China Elect Power Univ, Key Lab Power Syst Protect & Dynam Secur Monitori, Beijing, Peoples R China
关键词
wind power; voltage dip; low voltage ride-through (LVRT); transient voltage control; rotor-side converter;
D O I
10.1109/ICEET.2009.293
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Currently, some of the variable speed wind turbine on market have some low-voltage through capacity (LVRT), but do not have dynamic reactive power support capacity under fault.DFIG can't provide dynamic voltage support, in addition, as a result of lower terminal voltage, active power can not be completely output, which has impact on safe and stable operation of power grid. Aimed at this problem, this paper discussed how to improve the reactive power support capacity during grid fault such as three-phase voltage dip fault and presented a improved LVRT technology. First, the paper analyzed the transient responses and characteristics of DFIG under grid voltage fault and introduced several control strategies and protection programs of DFIG under voltage dip existing now; then, based on the traditional control strategy, the paper presented a transient voltage control strategy in rotor-side converter which can make DFIG output more reactive power to participate in the transient voltage control of whole grid during voltage dip in grid fault and during the recovery process after the fault to ensure that the terminal voltage of generator maintain the value before fault; finally, the EMTDC / PSCAD simulation showed that adopted transient voltage control strategy in rotor-side converter, the transient voltage control in rotor-side converter can output a large number of reactive power during fault according to the dip depth of terminal voltage to provide dynamic voltage support and insure the fast recovery of grid voltage.
引用
收藏
页码:228 / 231
页数:4
相关论文
共 50 条
  • [31] Study of brushless doubly-fed control for VSCF wind power generation system connected to grid
    Wang Qi
    Chen Xiao-hu
    Fei Wan-min
    Ji Yan-chao
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 2453 - 2458
  • [32] A control scheme to enhance low voltage ride-through of brushless doubly-fed induction generators
    Tohidi, S.
    Oraee, H.
    Zolghadri, M. R.
    Rahimi, M.
    WIND ENERGY, 2016, 19 (09) : 1699 - 1712
  • [33] Modeling and parameter optimization of HTS-FCL based on low voltage ride-through of doubly-fed wind farm
    Song W.
    Wang Q.
    Li Y.
    Wang X.
    Zhou S.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (18): : 99 - 107
  • [34] Quantitative Evaluation of Low Voltage Ride-through Control Strategies for Doubly-fed Induction Generators
    Deng S.
    Zhang X.
    Liu H.
    Chen L.
    Zhang, Xuemin (zhangxuemin@mail.tsinghua.edu.cn), 2018, Automation of Electric Power Systems Press (42): : 28 - 35
  • [35] Low voltage ride-through of doubly-fed induction generator based on rotor series resistor
    Zhang, Wenjuan
    Ma, Haomiao
    Zhang, Guokai
    Zhang, Feige
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2015, 35 (12): : 28 - 33
  • [36] Influence of low-voltage ride-through control techniques on the thermal behavior of power converters applied to wind energy conversion systems based on the doubly-fed induction generator
    de Oliveira, Igor Rodrigues
    Tofoli, Fernando Lessa
    Mendes, Victor Flores
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 239
  • [37] Fault ride-through capability enhancement of doubly-fed induction wind generators
    Mohseni, M.
    Islam, S.
    Masoum, M. A. S.
    IET RENEWABLE POWER GENERATION, 2011, 5 (05) : 368 - 376
  • [38] A new method based on state-estimation technique to enhance low-voltage ride-through capability of doubly-fed induction generator wind turbines
    Shahriari, Sayyed Ali Akbar
    Mohammadi, Mohammad
    Raoofat, Mandi
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 95 : 118 - 127
  • [39] Doubly fed induction generator wind turbines: A novel integrated protection circuit for low-voltage ride-through strategy
    Justo, Jackson John
    Mwasilu, Francis
    Jung, Jin-Woo
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2014, 6 (05)
  • [40] Efficient control scheme of wind turbines with doubly fed induction generators for low-voltage ride-through capability enhancement
    Rahimi, M.
    Parniani, M.