NON-LINEAR 3D RECONSTRUCTION FOR COMPRESSIVE X-RAY TOMOSYNTHESIS

被引:0
|
作者
Zhao, Qile [1 ]
Ma, Xu [1 ]
Cuadros, Angela [2 ]
Arce, Gonzalo R. [2 ]
Chen, Rui [3 ]
机构
[1] Beijing Inst Technol, Sch Opt & Photon, Minist Educ China, Key Lab Photoelect Imaging Technol & Syst, Beijing 100081, Peoples R China
[2] Univ Delaware, Dept Elect & Comp Engn, Newark, DE 19716 USA
[3] Chinese Acad Sci, Inst Microelect, Integrated Circuit Adv Proc Ctr, Beijing 100029, Peoples R China
基金
美国国家科学基金会;
关键词
X-ray tomosynthesis; non-linear reconstruction; compressed sensing; coding mask; OPTIMIZATION; ALGORITHM;
D O I
暂无
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Compressive X-ray tomosynthesis is an emerging technology that can be used for medical diagnosis, safety inspection and industrial non-destructive testing. Traditional compressive X-ray tomosynthesis uses sequential illumination to interrogate the object of interest, which generates non-overlapping projection measurements. However, when multiple X-ray sources emit simultaneously, the projections corresponding to different sources overlap creating multiplexed measurements. Such measurement strategy leads to a non-linear reconstruction problem. The reconstruction of the three-dimensional (3D) object from multiplexed projections is an important problem. This paper proposes a non-linear 3D reconstruction approach for compressive X-ray tomosynthesis, where a set of coding masks are used to generate structured illumination and reduce radiation dose. The effectiveness of the method is verified by simulation experiments. It is shown that the proposed approach can reconstruct high-quality images with just a few snapshots.
引用
收藏
页码:3149 / 3153
页数:5
相关论文
共 50 条
  • [21] Evaluation of the X-ray digital linear tomosynthesis reconstruction processing method for metal artifact reduction
    Gomi, Tsutomu
    Hirano, Hiroshi
    Umeda, Tokuo
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2009, 33 (04) : 267 - 274
  • [22] The discovery of non-linear X-ray variability in NGC 4051
    Green, AR
    McHardy, IM
    Done, C
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 1999, 305 (02) : 309 - 318
  • [23] Non-linear quantum regime of an X-ray wiggler laser
    Avetissian, HK
    Mkrtchian, GF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 483 (1-2): : 548 - 552
  • [24] Source and coded aperture joint optimization for compressive X-ray tomosynthesis
    Ma, Xu
    Zhao, Qile
    Cuadro, Angela
    Mao, Tianyi
    Arce, Gonzalo R.
    OPTICS EXPRESS, 2019, 27 (05) : 6640 - 6659
  • [25] Single-snapshot X-ray imaging for nonlinear compressive tomosynthesis
    Zhao, Qile
    Ma, Xu
    Cuadros, Angela
    Mao, Tianyi
    Arce, Gonzalo R.
    OPTICS EXPRESS, 2020, 28 (20) : 29390 - 29407
  • [26] Non-Linear 3D Impedance Spectroscopy
    1600, IEEE Computer Society (12):
  • [27] Non-Linear 3D Impedance Spectroscopy
    Zamora, M.
    Trujillo, M.
    Felice, C.
    IEEE LATIN AMERICA TRANSACTIONS, 2014, 12 (05) : 895 - 898
  • [28] Joint iterative reconstruction and 3D rigid alignment for X-ray tomography
    Pande, K.
    Donatelli, J. J.
    Parkinson, D. Y.
    Yan, H.
    Sethian, J. A.
    OPTICS EXPRESS, 2022, 30 (06) : 8898 - 8916
  • [29] 3D Shape Reconstruction of Loop Objects in X-Ray Protein Crystallography
    Strutz, Tilo
    IEEE-ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2011, 8 (03) : 797 - 807
  • [30] 3D reconstruction of volume defects from few X-ray images
    Lehr, C
    Liedtke, CE
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, 1999, 1689 : 275 - 284