NON-LINEAR 3D RECONSTRUCTION FOR COMPRESSIVE X-RAY TOMOSYNTHESIS

被引:0
|
作者
Zhao, Qile [1 ]
Ma, Xu [1 ]
Cuadros, Angela [2 ]
Arce, Gonzalo R. [2 ]
Chen, Rui [3 ]
机构
[1] Beijing Inst Technol, Sch Opt & Photon, Minist Educ China, Key Lab Photoelect Imaging Technol & Syst, Beijing 100081, Peoples R China
[2] Univ Delaware, Dept Elect & Comp Engn, Newark, DE 19716 USA
[3] Chinese Acad Sci, Inst Microelect, Integrated Circuit Adv Proc Ctr, Beijing 100029, Peoples R China
基金
美国国家科学基金会;
关键词
X-ray tomosynthesis; non-linear reconstruction; compressed sensing; coding mask; OPTIMIZATION; ALGORITHM;
D O I
暂无
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Compressive X-ray tomosynthesis is an emerging technology that can be used for medical diagnosis, safety inspection and industrial non-destructive testing. Traditional compressive X-ray tomosynthesis uses sequential illumination to interrogate the object of interest, which generates non-overlapping projection measurements. However, when multiple X-ray sources emit simultaneously, the projections corresponding to different sources overlap creating multiplexed measurements. Such measurement strategy leads to a non-linear reconstruction problem. The reconstruction of the three-dimensional (3D) object from multiplexed projections is an important problem. This paper proposes a non-linear 3D reconstruction approach for compressive X-ray tomosynthesis, where a set of coding masks are used to generate structured illumination and reduce radiation dose. The effectiveness of the method is verified by simulation experiments. It is shown that the proposed approach can reconstruct high-quality images with just a few snapshots.
引用
收藏
页码:3149 / 3153
页数:5
相关论文
共 50 条
  • [1] Calibration of X-ray projections in 3D reconstruction
    Wang, P
    Mou, XQ
    Qin, ZY
    Cai, YL
    VISUALIZATION AND OPTIMIZATION TECHNIQUES, 2001, 4553 : 44 - 49
  • [2] Coded aperture optimization for compressive X-ray tomosynthesis
    Cuadros, Angela P.
    Peitsch, Christopher
    Arguello, Henry
    Arce, Gonzalo R.
    OPTICS EXPRESS, 2015, 23 (25): : 32788 - 32802
  • [3] Filter calculation for x-ray tomosynthesis reconstruction
    Nielsen, Tim
    Hitziger, Sebastian
    Grass, Michael
    Iske, Armin
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3915 - 3930
  • [4] Non-linear X-ray variability in X-ray binaries and active galaxies
    Uttley, P
    McHardy, IM
    Vaughan, S
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2005, 359 (01) : 345 - 362
  • [5] 3D reconstruction with X-ray CT for nondestructive inspection
    Tanaka, Toshiyuki
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2008, 94 (07): : 483 - 486
  • [6] 3D x-ray reconstruction using lightfield imaging
    Saha, Sajib
    Tahtali, Murat
    Lambert, Andrew
    Pickering, Mark
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS III, 2014, 9209
  • [7] X-ray linear and non-linear spectroscopy of the ESCA molecule
    Nenov, Artur
    Segatta, Francesco
    Bruner, Adam
    Mukamel, Shaul
    Garavelli, Marco
    JOURNAL OF CHEMICAL PHYSICS, 2019, 151 (11):
  • [8] 3D visualization of x-ray tomosynthesis digital mammography data: Preference study
    Alyassin, AM
    Eberhard, JW
    Claus, BEH
    Kaufhold, J
    Trotter, DEG
    Kapur, A
    Pakenas, WP
    Landberg, CE
    Galbo, C
    Thomas, JA
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 507 - 509
  • [9] 3D motion reconstruction and integration based on non-linear subspace
    Zhu, HongLi
    Xiang, Jian
    ADVANCED RESEARCH ON MATERIAL ENGINEERING AND ITS APPLICATION, 2012, 485 : 399 - +
  • [10] Optimization of the structured illumination series for compressive x-ray tomosynthesis
    Xu, Hao
    Ma, Xu
    Zhao, Qile
    Restrepo, Carlos M.
    Arce, Gonzalo R.
    APPLIED OPTICS, 2021, 60 (09) : 2686 - 2694