Dynamic Flat field correction in X-ray computed tomography

被引:0
|
作者
Van Nieuwenhove, Vincent [1 ]
De Beenhouwer, Jan [1 ]
Marone, F. [2 ]
Mancini, L. [3 ]
Sijbers, Jan [1 ]
机构
[1] Univ Antwerp, iMinds Vis Lab, Univ Pl 1,Bldg N, B-2610 Antwerp, Belgium
[2] Paul Scherrer Inst, WBBA 216, CH-5232 Villigen, Switzerland
[3] Elettra Sincrotrone Trieste SCpA, SS 14 Km 163,5 Area Sci Pk, I-34149 Trieste, Italy
关键词
RECONSTRUCTIONS; DETECTORS;
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In computed tomography (CT), X-ray projections are acquired from different angles, which are then used to reconstruct a 3D image. Prior to reconstruction, the projections have to be normalised with respect to a white field, which is generally referred to as Flat Field Correction (FFC). The white field is computed from projections acquired without object between the x-ray source and detector. Conventional FFC assumes the flat fields to be stationary. However, due to beam intensity changes, temperature fluctuations or detector efficiency fluctuations, dynamic changes are observed resulting in projections that are not properly FFC corrected. We propose an efficient procedure to model and correct for flat field dynamics. The dynamics of the flat fields are described by eigen flat fields, derived from a series of prior and/or post flat fields using Principal Components Analysis (PCA). A time dependent flat field can then be approximated by a linear combination of the mean flat field and a limited number of eigen flat fields (EFF). The weights of these EEF in a Xray projections are estimated by minimizing the total variation using a non-linear optimization algorithm. Results on synchrotron CT datasets show that the proposed technique results in projections with almost no artefacts due to flat field fluctuations. Furthermore, the reconstructions show reduced flat field induced artefacts.
引用
收藏
页码:343 / 352
页数:10
相关论文
共 50 条
  • [21] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [22] An improved method for flat-field correction of flat panel x-ray detector
    Kwan, ALC
    Seibert, JA
    Boone, JM
    MEDICAL PHYSICS, 2006, 33 (02) : 391 - 393
  • [23] Industrial X-ray computed tomography
    Pechstein, Torsten
    TM-TECHNISCHES MESSEN, 2020, 87 (02) : 79 - 80
  • [24] Design for X-Ray Computed Tomography
    Moroni, Giovanni
    Petro, Stefano
    29TH CIRP DESIGN CONFERENCE 2019, 2019, 84 : 173 - 178
  • [25] Industrial computed X-ray tomography
    Luthi, T
    Flisch, A
    Wyss, P
    INSIGHT, 1998, 40 (03) : 196 - 197
  • [26] Dose in x-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : R129 - R150
  • [27] X-ray computed tomography of the heart
    Wijesekera, Nevin T.
    Duncan, Mark K.
    Padley, Simon P. G.
    BRITISH MEDICAL BULLETIN, 2010, 93 (01) : 49 - 67
  • [28] X-ray computed tomography using projection X-ray microscope
    Yoshimura, F
    Miyata, C
    Kuzuryu, C
    Hori, A
    Obi, T
    Ohyama, N
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 166 - 171
  • [29] Carbon Nanotube Field Emission X-ray System for Computed Tomography
    Ryu, Je Hwang
    Kim, Wan Sun
    Lee, Seung Ho
    Kang, Jung Su
    Kim, Jae Gon
    Lee, Soo Yeol
    Park, Kyu Chang
    Park, Hun Kuk
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [30] Application of Segmentation for Correction of Intensity Bias in X-Ray Computed Tomography Images
    Iassonov, Pavel
    Tuller, Markus
    VADOSE ZONE JOURNAL, 2010, 9 (01) : 187 - 191