Wet gas overreading characteristics of a long-throat Venturi at high pressure based on CFD

被引:7
|
作者
Xu, Ying [1 ,2 ]
Gao, Lu [1 ,2 ]
Zhao, Yi [3 ]
Wang, Huaxiang [1 ,2 ]
机构
[1] Key Lab Proc Measurement & Control Tianjin, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Sch Elect Engn & Automat, Tianjin 300072, Peoples R China
[3] Tianjin Inst Metrol Supervis & Testing, Tianjin 300192, Peoples R China
关键词
Nonstandard long-throat Venturi meter (LTVM); Wet gas; Computational fluid dynamics (CFD); Overreading (OR) correlation; Equivalent droplet diameter; FLOW;
D O I
10.1016/j.flowmeasinst.2014.09.004
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Based on the operational conditions of the PetroChina Southwest Oil & Gas well field, this study aims to explore the wet gas flow overreading (OR) characteristics of a nonstandard long-throat Venturi by the means of computational fluid dynamics (CFD) technique. The studied prototype structure size is an inner diameter of 50 mm, a diameter ratio of 0.4 and a throat length of 50 mm. According to the field experiment, the simulation pressure is 3 MPa gauge. Through a comparative study of the multiphase flow models and turbulence models, combined with the analysis of the Baker's flow regime and interparticle space under the field conditions, this paper eventually employed DPM model and Eulerian model for wet gas simulation, respectively, and RSM for turbulence model. An equivalent droplet diameter adjustment method was implemented to improve the precision of prediction. During post-processing, the liquid phase distributions and the wall pressure profiles were investigated. The numerical results indicate that the differential pressure in convergent section of long-throat Venturi by using DPM model is less than that by using Eulerian model, and the differential pressures in the divergent section by using the two models are analogous. Afterwards, the OR prediction correlations based on the differential pressure ratio method were proposed, and then compared and validated by the industrial field tests. The root mean square errors (RMSE) and the average relative errors predicted by Eulerian model were 4.24% and 3.78%, 5.69% and 5.01% by using DPM model, respectively. In conclusion, Eulerian model is more suitable for wet gas flow prediction. And some advice on the improvement of the multiphase flow simulation is provided to get a more preferable performance in wet gas flow prediction. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:247 / 255
页数:9
相关论文
共 50 条
  • [41] CFD Modelling and Numerical Simulation of the Windage Characteristics of a High-Speed Gearbox Based on Negative Pressure Regulation
    Huang, Bo
    Zhang, Hong
    Ding, Yiqun
    PROCESSES, 2023, 11 (03)
  • [42] High-current channel characteristics in high-pressure gas
    Pinchuk, M. E.
    Bogomaz, A. A.
    Budin, A. V.
    Leont'ev, V. V.
    Leks, A. G.
    Pozubenkov, A. A.
    Rutberg, Ph G.
    XXX INTERNATIONAL CONFERENCE ON INTERACTION OF INTENSE ENERGY FLUXES WITH MATTER (ELBRUS 2015), 2015, 653
  • [43] Flow and Heat-transfer Simulation Based on CFD and Experimental Study during High-Pressure Gas Quenching
    Wang, Zhijian
    Shang, Xiaofeng
    APPLIED MECHANICS AND MECHANICAL ENGINEERING, PTS 1-3, 2010, 29-32 : 1436 - 1440
  • [44] CFD simulation of pressure fluctuation characteristics in the gas-solid fluidized bed: Comparisons with experiments
    Wang Qingcheng
    Zhang Kai
    Gu Hongyan
    PETROLEUM SCIENCE, 2011, 8 (02) : 211 - 218
  • [46] CFD simulation of pressure fluctuation characteristics in the gas-solid fluidized bed:Comparisons with experiments
    Wang QingchengZhang Kai and Gu Hongyan Beijing Shenwu Thermal Energy Technology CoLTDBeijing China State Key Laboratory of Heavy Oil ProcessingChina University of PetroleumBeijing China National Engineering Lab for Biomass Power Generation EquipmentNorth China Electric Power UniversityBeijing China Electrical Engineering CollegeGuizhou UniversityGuiyang China
    Petroleum Science, 2011, 8 (02) : 211 - 218
  • [47] The Effects of Nozzle and Workpiece Placements on Cooling Rate in the Vacuum High-pressure Gas Quenching Furnace Based on CFD
    Wang, Zhijian
    Wang, Xiaoyan
    Shang, Xiaofeng
    MECHANICAL, MATERIALS AND MANUFACTURING ENGINEERING, PTS 1-3, 2011, 66-68 : 673 - 676
  • [48] A new correlation for wet gas flow rate measurement with Venturi meter based on two-phase mass flow coefficient
    He, Denghui
    Bai, Bofeng
    MEASUREMENT, 2014, 58 : 61 - 67
  • [49] Study on pressure fluctuations of Francis turbine with long and short blades based on CFD
    Zhang, Siqing
    Hu, Xiucheng
    Zhang, Lixiang
    Yu, Fengrong
    Li, Changzhen
    Shuili Fadian Xuebao/Journal of Hydroelectric Engineering, 2012, 31 (02): : 216 - 221
  • [50] CFD numerical simulation of wet flue gas desulfurization:performance improvement based on gas-liquid mass transfer enhancement
    Li W.
    Zhao Z.
    Ni Z.
    Zhou C.
    Zheng C.
    Gao X.