On the Beat Detection Performance in Long-Term ECG Monitoring Scenarios

被引:12
|
作者
Melgarejo-Meseguer, Francisco-Manuel [1 ]
Everss-Villalba, Estrella [1 ]
Gimeno-Blanes, Francisco-Javier [2 ]
Blanco-Velasco, Manuel [3 ]
Molins-Bordallo, Zaida [1 ]
Flores-Yepes, Jose-Antonio [2 ]
Rojo-Alvarez, Jose-Luis [4 ,5 ]
Garcia-Alberola, Arcadi [1 ]
机构
[1] Hosp Gen Univ Virgen Arrixaca, Cardiol Serv, Arrhythmia Unit, Murcia 30120, Spain
[2] Miguel Hernandez Univ, Dept Signal Theory & Commun, Alicante 03202, Spain
[3] Univ Alcala, Dept Signal Theory & Commun, Madrid 28805, Spain
[4] Univ Politecn Madrid, Ctr Computat Simulat, Madrid 28223, Spain
[5] Rey Juan Carlos Univ, Dept Signal Theory & Commun, Madrid 28943, Spain
关键词
QRS detection; ECG; long-term monitoring; Holter; 7-day; QRS DETECTION; ATRIAL-FIBRILLATION; CATHETER ABLATION; RECOGNITION; COMPLEX; CLASSIFICATION; COMPONENTS; TRANSFORM; ALGORITHM;
D O I
10.3390/s18051387
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Despite the wide literature on R-wave detection algorithms for ECG Holter recordings, the long-term monitoring applications are bringing new requirements, and it is not clear that the existing methods can be straightforwardly used in those scenarios. Our aim in this work was twofold: First, we scrutinized the scope and limitations of existing methods for Holter monitoring when moving to long-term monitoring; Second, we proposed and benchmarked a beat detection method with adequate accuracy and usefulness in long-term scenarios. A longitudinal study was made with the most widely used waveform analysis algorithms, which allowed us to tune the free parameters of the required blocks, and a transversal study analyzed how these parameters change when moving to different databases. With all the above, the extension to long-term monitoring in a database of 7-day Holter monitoring was proposed and analyzed, by using an optimized simultaneous-multilead processing. We considered both own and public databases. In this new scenario, the noise-avoid mechanisms are more important due to the amount of noise that exists in these recordings, moreover, the computational efficiency is a key parameter in order to export the algorithm to the clinical practice. The method based on a Polling function outperformed the others in terms of accuracy and computational efficiency, yielding 99.48% sensitivity, 99.54% specificity, 99.69% positive predictive value, 99.46% accuracy, and 0.85% error for MIT-BIH arrhythmia database. We conclude that the method can be used in long-term Holter monitoring systems.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] The Genre of Applications requiring Long-Term and Continuous Monitoring of ECG Signals
    Bansal, Malti
    Gandhi, Bani
    2017 INTERNATIONAL CONFERENCE ON INNOVATIONS IN INFORMATION, EMBEDDED AND COMMUNICATION SYSTEMS (ICIIECS), 2017,
  • [42] Enhancing long-term ECG monitoring with graphic analysis of coupling intervals
    Sapoznikov, D
    Luria, MH
    Gotsman, MS
    JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 (02) : 137 - 145
  • [43] Very Long-Term ECG Monitoring Patch with Improved Functionality and Wearability
    Martinez-Tabares, F. J.
    Gaviria-Gomez, N.
    Castellanos-Dominguez, G.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5964 - 5967
  • [44] DEMONSTRATION OF COMPLEX VENTRICULAR TACHYARRHYTHMIAS BY LONG-TERM ECG MONITORING - RELATIONSHIP TO DURATION OF MONITORING
    ANDRESEN, D
    VONLEITNER, ER
    WEGSCHEIDER, K
    SCHRODER, R
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1982, 107 (15) : 571 - 574
  • [45] Instrumentation of bridges for long-term performance monitoring
    Feng, MQ
    Kim, DK
    Sheng, LH
    Fiji, LM
    Kim, YJ
    HEALTH MONITORING AND MANAGEMENT OF CIVIL INFRASTRUCTURE SYSTEMS, 2001, 4337 : 139 - 146
  • [46] SCENARIOS IN LONG-TERM PLANNING
    JULIEN, PA
    LAMONDE, P
    LATOUCHE, D
    ACTUALITE ECONOMIQUE, 1975, 51 (02): : 253 - 281
  • [47] Preserving Abnormal Beat Morphology in Long-Term ECG Recording: An Efficient Hybrid Compression Approach
    Bera, Priyanka
    Gupta, Rajarshi
    Saha, Jayanta
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (05) : 2084 - 2092
  • [48] Smart ECG Monitoring Patch with Built-in R-Peak Detection for Long-Term HRV Analysis
    Lee, W. K.
    Yoon, H.
    Park, K. S.
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (07) : 2292 - 2301
  • [49] An approach to reliable motion artifact detection for mobile long-term ECG monitoring systems using dry electrodes
    Ottenbacher, J.
    Kirst, M.
    Jatoba, L.
    Grossmann, U.
    Stork, W.
    IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 440 - +
  • [50] Smart ECG Monitoring Patch with Built-in R-Peak Detection for Long-Term HRV Analysis
    W. K. Lee
    H. Yoon
    K. S. Park
    Annals of Biomedical Engineering, 2016, 44 : 2292 - 2301