Multi-echo balanced SSFP with a sequential phase-encoding order for functional MR imaging at 7T

被引:1
|
作者
Liang, Huilou [1 ,2 ]
Pan, Ziyi [3 ]
Qian, Chencan [1 ,2 ]
Liu, Chengwen [4 ]
Sun, Kaibao [1 ]
Weng, Dehe [5 ]
An, Jing [5 ]
Zhuo, Yan [1 ,2 ]
Wang, Danny J. J. [6 ]
Guo, Hua [3 ]
Xue, Rong [1 ,2 ,7 ]
机构
[1] Chinese Acad Sci, Beijing MRI Ctr Brain Res, Inst Biophys, State Key Lab Brain & Cognit Sci, 15 Datun Rd, Beijing 100101, Peoples R China
[2] Univ Chinese Acad Sci, Beijing, Peoples R China
[3] Tsinghua Univ, Ctr Biomed Imaging Res, Sch Med, Dept Biomed Engn, Beijing, Peoples R China
[4] Cent South Univ, Xiangya Hosp 2, Med Psychol Ctr, Changsha, Peoples R China
[5] Siemens Shenzhen Magnet Resonance Ltd, Shenzhen, Peoples R China
[6] Univ Southern Calif, Mark & Mary Stevens Neuroimaging & Informat Inst, Lab FMRI Technol LOFT, Los Angeles, CA 90007 USA
[7] Beijing Inst Brain Disorders, Beijing, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
BOLD fMRI; echo-train readout; multi-echo; passband balanced SSFP; submillimeter in-plane resolution; ultrahigh field; GRADIENT-ECHO; HUMAN BRAIN; FMRI; SIGNAL; BSSFP; NOISE; OXYGENATION; REDUCTION; FREQUENCY; TRUEFISP;
D O I
10.1002/mrm.29301
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop a 2D multi-echo passband balanced SSFP (bSSFP) sequence using an echo-train readout with a sequential phase-encoding order (sequential multi-echo bSSFP), and evaluate its performance in fast functional brain imaging at 7 T. Methods As images of sequential multi-echo bSSFP exhibit multiple ghosts due to periodic k-space modulations, a GRAPPA-based reconstruction method was proposed to eliminate ghosting artifacts. MRI experiments were performed to compare the image quality of multi-echo bSSFP and conventional single-echo bSSFP. Submillimeter-resolution fMRI using a checkerboard visual stimulus was conducted to compare the activation characteristics of multi-echo bSSFP, conventional single-echo bSSFP and standard gradient-echo EPI (GE-EPI). Results A higher mean structural similarity index was found between images of single-echo bSSFP and multi-echo bSSFP with a shorter echo train length (ETL). Multi-echo bSSFP (ETL = 3) showed higher temporal SNR (tSNR) values than GRAPPA-accelerated single-echo bSSFP (R = 2). In submillimeter-resolution fMRI experiments, multi-echo bSSFP (ETL = 3) approached the imaging speed of GRAPPA-accelerated single-echo bSSFP (R = 2), but without tSNR penalty and reduced activation due to acceleration. The median t-value and the number of significantly activated voxels were comparable between GE-EPI and multi-echo bSSFP (ETL = 3) that provides virtually distortion-free functional images and inherits the activation patterns of conventional bSSFP. Conclusion Sequential multi-echo bSSFP (ETL = 3) is suitable for fast fMRI with submillimeter in-plane resolution, and offers an option to accelerate bSSFP imaging without tSNR penalty like parallel imaging.
引用
收藏
页码:1303 / 1313
页数:11
相关论文
共 35 条
  • [1] Use of multi-echo functional MR imaging to assess somatosensory activation
    Newton, J
    Francis, S
    Sleigh, A
    Sunderland, A
    Gowland, P
    NEUROIMAGE, 2001, 13 (06) : S918 - S918
  • [2] Myelin water imaging of in vivo and ex vivo human brains using multi-echo gradient echo at 3T and 7T
    Xu, Guojun
    Zhao, Zhiyong
    Zhu, Qinfeng
    Zhu, Keqing
    Zhang, Jing
    Wu, Dan
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 803 - 813
  • [3] THE IMPORTANCE OF PHASE-ENCODING ORDER IN ULTRA-SHORT TR SNAPSHOT MR IMAGING
    HOLSINGER, AE
    RIEDERER, SJ
    MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) : 481 - 488
  • [4] Imaging arterial and venous vessels using Iron Dextran enhanced multi-echo 3D gradient echo MRI at 7T
    Li, Yinghao
    Li, Wei
    Paez, Adrian
    Cao, Di
    Sun, Yuanqi
    Gu, Chunming
    Zhang, Kaihua
    Miao, Xinyuan
    Liu, Peiying
    Li, Wenbo
    Pillai, Jay
    Lu, Hanzhang
    van Zijl, Peter C. M.
    Earley, Christopher
    Li, Xu
    Hua, Jun
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [5] ALTERED PHASE-ENCODING ORDER FOR REDUCED SENSITIVITY TO MOTION IN 3-DIMENSIONAL MR IMAGING
    KORIN, HW
    RIEDERER, SJ
    BAMPTON, AEH
    EHMAN, RL
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (06): : 687 - 693
  • [6] Comparing the efficacy of data-driven denoising methods for a multi-echo fMRI acquisition at 7T
    Beckers, Abraham B.
    Drenthen, Gerhard S.
    Jansen, Jacobus F. A.
    Backes, Walter H.
    Poser, Benedikt A.
    Keszthelyi, Daniel
    NEUROIMAGE, 2023, 280
  • [7] Low SAR 31P (multi-echo) spectroscopic imaging using an integrated whole-body transmit coil at 7T
    van Houtum, Q.
    Welting, D.
    Gosselink, W. J. M.
    Klomp, D. W. J.
    Arteaga de Castro, C. S.
    van der Kemp, W. J. M.
    NMR IN BIOMEDICINE, 2019, 32 (12)
  • [8] Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging
    Posse, S
    Wiese, S
    Gembris, D
    Mathiak, K
    Kessler, C
    Grosse-Ruyken, ML
    Elghahwagi, B
    Richards, T
    Dager, SR
    Kiselev, VG
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (01) : 87 - 97
  • [9] Advances in MR angiography with 7T MRI: From microvascular imaging to functional angiography
    Park, Chan-A
    Kang, Chang-Ki
    Kim, Young-Bo
    Cho, Zang-Hee
    NEUROIMAGE, 2018, 168 : 269 - 278
  • [10] Myelin water imaging of in vivo and ex vivo human brains using multi-echo gradient echo at 3 T and 7 T
    Xu, Guojun
    Zhao, Zhiyong
    Zhu, Qinfeng
    Zhu, Keqing
    Zhang, Jing
    Wu, Dan
    MAGNETIC RESONANCE IN MEDICINE, 2024,