A theoretical approach based on electromagnetic scattering for analysing dielectric shimming in high-field MRI

被引:26
|
作者
Brink, Wyger M. [1 ]
Remis, Rob F. [2 ]
Webb, Andrew G. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, CJ Gorter Ctr High Field MRI, Postzone C3-Q,Albinusdreef 2, NL-2333 ZA Leiden, Netherlands
[2] Delft Univ Technol, Fac Elect Engn Math & Comp Sci, Circuits & Syst Grp, Delft, Netherlands
关键词
Dielectric shimming; B-1(+); electromagnetic scattering; integral equations; inverse problem; HIGH-PERMITTIVITY PADS; SIMULATIONS; MODELS; BRAIN;
D O I
10.1002/mrm.25783
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeIn this study, we analyzed dielectric shimming by formulating it as an electromagnetic scattering problem using integral equations. MethodsThree-dimensional simulations of the radiofrequency field in two configurations using different materials were analyzed in terms of induced currents and secondary fields. A two-dimensional integral equation method with different backgrounds was used to identify the underlying physical mechanisms. This framework was then used to develop an inversion method for the design of dielectric pads. ResultsThe effects of a dielectric pad can be attributed to the interference of a secondary field that is produced by the currents induced in the dielectric pad, radiating in an inhomogeneous background. The integral equation method with inhomogeneous background reduces the complexity of the forward and inverse problem significantly and can be used to optimize the permittivity distribution for a desired B-1(+) field. Agreement with experimental B-1(+) maps was obtained in a cylindrical phantom, demonstrating the validity of the method. ConclusionsThe integral equation method with inhomogeneous background yields an efficient numerical framework for the analysis and inverse design of dielectric shimming materials. Magn Reson Med 75:2185-2194, 2016. (c) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:2185 / 2194
页数:10
相关论文
共 50 条
  • [11] The Safety of High-Field MRI?
    Yilmaz, S.
    INTERNATIONAL JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2014, 5 (02): : 63 - 64
  • [12] A MODEL FOR HIGH-FIELD CONDUCTION IN A DIELECTRIC
    ODWYER, JJ
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1986, 21 (02): : 121 - 127
  • [13] HIGH-FIELD DIELECTRIC MEASUREMENTS IN WATER
    KOLODZIEJ, HA
    JONES, GP
    DAVIES, M
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS II, 1975, 71 (02): : 269 - 274
  • [14] High-field MRI for fetal autopsy
    不详
    ARCHIVES OF DISEASE IN CHILDHOOD, 2010, 95 (11) : 925 - 925
  • [15] Dipolectric antenna for high-field MRI
    Wenz, Daniel
    Xin, Lijing
    Dardano, Thomas
    Kuehne, Andre
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (04) : 1695 - 1712
  • [16] SOME ADVANTAGES OF HIGH-FIELD MRI
    GROSSI, G
    SCIELZO, G
    RIVISTA DI NEURORADIOLOGIA, 1995, 8 (05): : 691 - 692
  • [17] Clinical and high-field MRI in MRI negative epilepsy
    Martin, Pascal
    Bender, Benjamin
    CLINICAL EPILEPTOLOGY, 2023, 36 (02) : 98 - 103
  • [18] A Hybrid Field-Harmonics Approach for Passive Shimming Design in MRI
    Liu, Feng
    Zhu, Jianfeng
    Xia, Ling
    Crozier, Stuart
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (02) : 60 - 67
  • [19] ELECTROMAGNETIC FORCES IN HIGH-FIELD MAGNET COILS
    CALDWELL, J
    APPLIED MATHEMATICAL MODELLING, 1982, 6 (03) : 157 - 160
  • [20] Design and field theoretical analysis of a high-field coil
    Beigelbeck, Roman
    Keplinger, Franz
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2022, 139 (06): : 494 - 503