Electropreconcentration, gate injection, and capillary electrophoresis separation on a microchip

被引:3
|
作者
Chun, Honggu [1 ]
机构
[1] Korea Univ, Dept Biomed Engn, 466 Hana Sci Hall,145 Anamro, Seoul 02841, South Korea
基金
新加坡国家研究基金会;
关键词
Electropreconcentration; Ion concentration polarization; Capillary electrophoresis; Gate injection; ION CONCENTRATION POLARIZATION; SAMPLE PRECONCENTRATION; MICROFLUIDIC DEVICES; ELECTROSPRAY-IONIZATION; STACKING; CHARGE; CHIP; PROTEINS; DEPLETION; MEMBRANE;
D O I
10.1016/j.chroma.2018.08.053
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The nanochannel-based electropreconcentration is not compatible with successive capillary zone electrophoresis (CZE). In this study, the incompatibility is theoretically discussed and experimentally proven, and then, the development of a monolithic glass microfluidic chip for performing integrated electropreconcentration and CZE separation is described. The sample is electropreconcentrated at the interface of a micro- and nanochannel where electric double layer overlap conditions exist. Because an ion-depletion region develops at the leading front of the preconcentrated plug, a field-enhanced sample stacking effect occurs which limits the separation efficiency unless compensated for. The ion-depletion region was confirmed by monitoring the solution conductivity at discrete points in the microchannel during the preconcentration step. The solution conductivity decreased >20-fold during the preconcentration step. To overcome the effects of this region, a cross-intersection was used to shunt the ion-depleted buffer away from the analysis channel while reintroducing the running buffer. When the preconcentrated sample plug arrives at the cross-intersection, it is gate injected into the analysis channel so that fresh running buffer surrounds the plug. Under these conditions, three-peptide mixture was preconcentrated 200 fold in 60 s and the preconcentrated plug was successfully resolved with better than 1% relative standard deviations in migration times. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 50 条
  • [21] A special issue on high performance separation and analysis by capillary and microchip electrophoresis
    Otsuka, K
    ANALYTICAL SCIENCES, 2005, 21 (01) : 3 - 3
  • [22] Instrumentation for Capillary and Microchip Electrophoresis
    Carrilho, Emanuel
    Garcia, Carlos D.
    ELECTROPHORESIS, 2012, 33 (17) : 2613 - 2613
  • [23] Carbon nanotubes in capillary electrophoresis, capillary electrochromatography and microchip electrophoresis
    Pauwels, Jochen
    Van Schepdael, Ann
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (03): : 785 - 801
  • [24] Capillary electrophoresis and microchip capillary electrophoresis with electrochemical and electrochemiluminescence detection
    Du, Yan
    Wang, Erkang
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (06) : 875 - 890
  • [25] Combination of flow injection with capillary electrophoresis - Part 7. Microchip capillary electrophoresis system with flow injection sample introduction and amperometric detection
    Fu, CG
    Fang, ZL
    ANALYTICA CHIMICA ACTA, 2000, 422 (01) : 71 - 79
  • [26] Fluorescence Monitoring of Microchip Capillary Electrophoresis Separation with Monolithically Integrated Optical Waveguides
    Dongre, C.
    Dekker, R.
    Hoekstra, H. J. W. M.
    Martinez-Vazquez, R.
    Osellame, R.
    Ramponi, R.
    Cerullo, G.
    van Weeghel, R.
    Besselink, G. A. J.
    van den Vlekkert, H. H.
    Pollnau, M.
    2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 1489 - +
  • [27] Recent developments in instrumentation for capillary electrophoresis and microchip-capillary electrophoresis
    Felhofer, Jessica L.
    Blanes, Lucas
    Garcia, Carlos D.
    ELECTROPHORESIS, 2010, 31 (15) : 2469 - 2486
  • [28] Microchip capillary electrophoresis with amperometric detection for rapid separation and detection of phenolic acids
    Scampicchio, M
    Wang, J
    Mannino, S
    Chatrathi, MP
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1049 (1-2) : 189 - 194
  • [29] Revisiting electroosmotic flow: An important parameter affecting separation in capillary and microchip electrophoresis
    Ahmadzadeh, Hossein
    Prescott, Matthew
    Muster, Nemone
    Stoyanov, Alexandre
    CHEMICAL ENGINEERING COMMUNICATIONS, 2008, 195 (02) : 129 - 146
  • [30] The application of polyester microchip to capillary electrophoresis
    Xu, W
    Uchiyama, K
    Shimosaka, T
    Hobo, T
    CHEMISTRY LETTERS, 2000, (07) : 762 - 763