The Advantages of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Assessment of Tricuspid Valve Infective Endocarditis

被引:10
|
作者
Sungur, Aylin [1 ]
Hsiung, Ming C. [2 ]
Quiroz, Luis D. Meggo [1 ]
Oez, Tugba Kemaloglu [1 ]
Asaad, Ayman Haj [1 ]
Joshi, Deepak [1 ]
Doenmez, Cevdet [1 ]
Guevenc, Tolga S. [1 ]
Nanda, Navin C. [1 ]
机构
[1] Univ Alabama Birmingham, Div Cardiovasc Dis, Birmingham, AL 35294 USA
[2] Cheng Hsin Gen Hosp, Div Cardiol, Taipei, Taiwan
关键词
live; real time three-dimensional transesophageal echocardiography; right-sided infective endocarditis; three-dimensional echocardiography; tricuspid valve infective endocarditis; tricuspid valve; endocarditis; DIAGNOSIS; QUANTIFICATION; ABSCESS;
D O I
10.1111/echo.12785
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Currently, tricuspid valve infective endocarditis (TVIE) is encountered in daily clinical practice more frequently due to the increasing prevalence of illicit intravenous drug use and the implantation of intracardiac devices. In this study, we compared findings from intra-operative live/real time three-dimensional transesophageal echocardiograms (3DTEE) and two-dimensional transesophageal echocardiograms (2DTEE) of 10 patients who underwent surgery for native tricuspid valve (TV) endocarditis. Unlike 2DTEE, 3DTEE allowed en face visualization of the 3 TV leaflets from both, atrial and ventricular aspects, in 9 of the 10 cases. In the remaining patient, in whom 3DTEE could not identify all 3 leaflets en face, the TV was found essentially destroyed at surgery. Using 3DTEE, the number of vegetations was accurately reported when compared with the surgical record. Furthermore, the orientation of each vegetation was the same as noted in the surgical findings. 2DTEE missed the identification of vegetations in 5 patients. The attachment site of vegetations to the TV were also not characterized by 2DTEE in 5 patients. In all 10 cases, 3DTEE characterized the vegetations more accurately with larger dimensions, including those in the azimuthal axis, and volumes. In addition, a perivalvular abscess that lead to surgical intervention was identified by 3DTEE, however, missed by 2DTEE. In conclusion, 3DTEE allows en face visualization of the TV apparatus permitting accurate description of the number and dimensions of vegetations identified by our surgical standard, which ultimately informs patients' prognosis and dictates the timing and planning for surgical intervention. Its use should be in conjunction with 2DTEE when evaluating TVIE.
引用
收藏
页码:1293 / 1309
页数:17
相关论文
共 50 条
  • [21] Real-Time Three-Dimensional Transesophageal Echocardiography Assessment of the Mitral Valve: Perioperative Advantages and Game-Changing Findings
    Moustafa, Sherif E.
    Chandrasekaran, Krishnaswamy
    Khandheria, Bijoy
    Tajik, Jamil
    Mookadam, Farouk
    JOURNAL OF HEART VALVE DISEASE, 2011, 20 (02): : 114 - 122
  • [22] Assessment of mitral prosthetic valve thrombosis by live three-dimensional echocardiography: comparison with transesophageal echocardiography
    Moreo, Antonella
    Lobiati, Elisabetta
    De Chiara, Benedetta
    Mauri, Francesco
    HEART AND VESSELS, 2007, 22 (04) : 287 - 289
  • [23] Assessment of mitral prosthetic valve thrombosis by live three-dimensional echocardiography: comparison with transesophageal echocardiography
    Antonella Moreo
    Elisabetta Lobiati
    Benedetta De Chiara
    Francesco Mauri
    Heart and Vessels, 2007, 22 : 287 - 289
  • [24] Real-Time Three-Dimensional Transesophageal Echocardiography in the Intraoperative Assessment of Mitral Valve Disease
    Grewal, Jasmine
    Mankad, Sunil
    Freeman, William K.
    Click, Roger L.
    Suri, Rakesh M.
    Abel, Martin D.
    Oh, Jae K.
    Pellikka, Patricia A.
    Nesbitt, Gillian C.
    Syed, Imran
    Mulvagh, Sharon L.
    Miller, Fletcher A.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) : 34 - 41
  • [25] Live three-dimensional transesophageal echocardiography in mitral valve surgery
    Ma Ning
    Li Zhi-An
    Meng Xu
    Yang Ya
    CHINESE MEDICAL JOURNAL, 2008, 121 (20) : 2037 - 2041
  • [26] Live three-dimensional transesophageal echocardiography in mitral valve surgery
    MA NingLI ZhianMENG Xu and YANG Ya Department of Ultrasonography Department of Cardiac Surgery Beijing Anzhen HospitalCapital Medical UniversityBeijing China
    中华医学杂志(英文版), 2008, (20) : 2037 - 2041
  • [27] Usefulness of real-time three-dimensional echocardiography for diagnosis of infective endocarditis
    Liu, Yen-Wen
    Tsai, Wei-Chuan
    Lin, Chih-Chan
    Hsu, Chih-Hsing
    Li, Wei-Ting
    Lin, Li-Jen
    Chen, Jyh-Hong
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2009, 43 (05) : 318 - 323
  • [28] Assessment of normal tricuspid valve anatomy in adults by real-time three-dimensional echocardiography
    Anwar, Ashraf M.
    Geleijnse, Marcel L.
    Soliman, Osama I. I.
    McGhie, Jackie S.
    Frowijn, Rene
    Nemes, Attila
    van den Bosch, Annemien E.
    Galema, Tjebbe W.
    ten Cate, Folkert J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (06): : 717 - 724
  • [29] Assessment of normal tricuspid valve anatomy in adults by real-time three-dimensional echocardiography
    Ashraf M. Anwar
    Marcel L. Geleijnse
    Osama I. I. Soliman
    Jackie S. McGhie
    René Frowijn
    Attila Nemes
    Annemien E. van den Bosch
    Tjebbe W. Galema
    Folkert J. ten Cate
    The International Journal of Cardiovascular Imaging, 2007, 23 : 717 - 724
  • [30] Assessment of tricuspid valve annulus size and shape with real-time three-dimensional echocardiography
    Anwar, A.
    Soliman, O.
    Geleijnse, M.
    Mcghie, J.
    Nemes, A.
    Ten Cate, F.
    EUROPEAN HEART JOURNAL, 2006, 27 : 707 - 707