A survey of regional guidelines for intrapartum electronic fetal monitoring in women at low obstetric risk

被引:5
|
作者
Hinsliff, SW [1 ]
Hindley, C [1 ]
Thomson, AM [1 ]
机构
[1] Univ Manchester, Sch Nursing Midwifery & Social Work, Manchester M60 7LP, Lancs, England
关键词
evidence-based practice; clinical guidelines; electronic fetal monitoring; appraisal tool;
D O I
10.1016/j.midw.2004.03.001
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Aim: to determine whether intrapartum fetal monitoring guidelines used by midwives in one region of England for women at low risk of obstetric complications were evidence-based. Objective: to assess the quality of such guidelines using an appraisal tool. Design and setting: an appraisal of guidelines gained via a postal survey of all National Health Service Trusts supplying maternity services in one region in the north of England, conducted over a six-week period (June-July 2001). Participants: 28 Trusts were eligible to participate; 32 guidelines were returned from 24 Trusts. Data analysis: two reviewers from a multi-disciplinary panel appraised each guideline, producing two sets of data that were analysed independently of each other. Each was treated as a separate case (n = 64 cases). Inter-reviewer agreement was summarised using descriptive categories. Findings: the highest possible overall quality score was 54, and the lowest 18. Whilst no guideline scored 54, five of the 64 cases scored 18. The mean overall quality score was 26.8. In 36 of the 64 cases, both reviewers rated guidelines as 'definitely not' recommended for practice. Guidelines were scored against specific aspects of evidence-based practice. Forty-one of the 64 cases received the lowest possible quality score (= '1') for use of systematic reviews of the literature on electronic fetal monitoring. In 47 cases, guidelines were scored '1' for the quality of evidence-based clinical recommendations. The quality of information on client monitoring preferences was considered low in over half the 64 cases (n = 35). There were no instances where the number of cases receiving 'highest possible quality' scores was greater than those receiving 'lowest possible quality' ratings. Conclusions and implications for practice: a small number of guidelines were assessed as high quality, but the majority were poorly appraised by the reviewer group in most areas. This has implications for the delivery of evidence-based midwifery care since those midwives practising according to the guidelines surveyed would not have been supported in implementing research into practice. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:345 / 357
页数:13
相关论文
共 50 条
  • [31] Recommendations for intrapartum fetal monitoring are not followed in low-risk women: A study from two Norwegian birth units
    Rosset, Ida Karin
    Lindahl, Kaia
    Blix, Ellen
    Kaasen, Anne
    SEXUAL & REPRODUCTIVE HEALTHCARE, 2020, 26
  • [32] FIGO consensus guidelines on intrapartum fetal monitoring: Physiology of fetal oxygenation and the main goals of intrapartum fetal monitoring (vol 131, pg 5, 2015)
    Ayres-de-Campos, Diogo
    Arulkumaran, Sabaratnam
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2016, 133 (02) : 255 - 255
  • [33] Predictive value of electronic fetal monitoring for intrapartum fetal asphyxia with metabolic acidosis
    Low, JA
    Victory, R
    Derrick, EJ
    OBSTETRICS AND GYNECOLOGY, 1999, 93 (02): : 285 - 291
  • [34] Computerized intrapartum electronic fetal monitoring: analysis of the decision to deliver for fetal distress
    Georgieva, Antoniya
    Payne, Stephen J.
    Moulden, Mary
    Redman, Christopher W. G.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 5888 - 5891
  • [35] DIFFERENCES IN INTRAPARTUM OBSTETRIC CARE PROVIDED TO WOMEN AT LOW-RISK BY FAMILY PHYSICIANS AND OBSTETRICIANS
    REID, AJ
    CARROLL, JC
    RUDERMAN, J
    MURRAY, MA
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1989, 140 (06) : 625 - 633
  • [36] INTRAPARTUM ELECTRONIC FETAL HEART-RATE MONITORING REVISITED
    PATTINSON, RC
    SOUTH AFRICAN MEDICAL JOURNAL, 1992, 81 (05): : 237 - 238
  • [37] ELECTRONIC FETAL MONITORING DEBATE Intrapartum cardiotocography and pattern recognition
    Sholapurkar, Shashikant L.
    BMJ-BRITISH MEDICAL JOURNAL, 2018, 360
  • [38] Efficacy and safety of intrapartum electronic fetal monitoring: An update - Reply
    Thacker, SB
    Stroup, DF
    Peterson, H
    OBSTETRICS AND GYNECOLOGY, 1996, 87 (03): : 477 - 477
  • [39] System errors in intrapartum electronic fetal monitoring: A case review
    Miller, LA
    JOURNAL OF MIDWIFERY & WOMENS HEALTH, 2005, 50 (06) : 507 - 516
  • [40] Predicting acidemia with intrapartum electronic fetal monitoring (EFM) patterns
    Cahill, Alison G.
    Odibo, Anthony
    Roehl, Kimberly
    Macones, George
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2012, 206 (01) : S44 - S44