PIV investigations of the flow field in the volute of a rotary blood pump

被引:11
|
作者
Sankovic, JM
Kadambi, JR
Mehta, M
Smith, WA
Wernet, MP
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] NASA, John H Glenn Res Ctr, Cleveland, OH 44135 USA
[3] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Cleveland, OH 44106 USA
[4] Cleveland Clin Fdn, Dept Biomed Engn, Lerner Res Ctr, Cleveland, OH 44195 USA
关键词
D O I
10.1115/1.1789529
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indecies of the fluid, the pump casing, and the impeller were matched to,facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 12 kPa and at a maximum flow condition. Four hundred data pairs were used,for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately +/-2.9%.
引用
收藏
页码:730 / 734
页数:5
相关论文
共 50 条
  • [21] A BLOOD PUMP FLOW VISUALIZATION USING A WALL-PIV TECHNIQUE
    Berthe, A.
    Kondermann, D.
    Christensen, C.
    Goubergrits, L.
    Kertzscher, U.
    Afteld, K.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (07): : 593 - 593
  • [22] Noninvasive pulsatile flow estimation for an implantable rotary blood pump
    Karantonis, Dean M.
    Cloherty, Shaun L.
    Mason, David G.
    Ayre, Peter J.
    Lovell, Nigel H.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1018 - +
  • [23] Mathematical modeling of a rotary blood pump in a pulsatile flow environment
    Pirbodaghi, T.
    Vandenberghe, S.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2010, 15 : 20 - 20
  • [24] Design and evaluation of a pulsatile flow rotary vane blood pump
    Li, Mengtang
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2023, 237 (11) : 2561 - 2574
  • [25] Sensorless flow and head estimation in the VentrAssist rotary blood pump
    Ayre, PJ
    Vidakovic, SS
    Tansley, GD
    Watterson, PA
    Lovell, NH
    ARTIFICIAL ORGANS, 2000, 24 (08) : 585 - 588
  • [26] Numerical Investigations of a Single Stage Volute Pump in Viscous Operation
    Chatagny L.
    Berten S.
    International Journal of Fluid Machinery and Systems, 2023, 16 (01) : 14 - 33
  • [27] Investigation of Blood Hemolysis Study in Rotary Blood Pump between Continuous Flow and Pulsatile Flow
    Rungsirikunnan, Chitsanupong
    Mondee, Kamonwan
    Gesprasert, Goragoch
    Naiyanetr, Phornphop
    2018 11TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2018), 2018,
  • [28] Flow field investigations in rotating facilities by means of stationary PIV systems
    Armellini, A.
    Mucignat, C.
    Casarsa, L.
    Giannattasio, P.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (02)
  • [29] Measurements in the dynamic pressure field of the volute of a centrifugal pump
    Parrondo, JL
    Fernandez, J
    Santolaria, C
    Gonzalez, J
    HYDRAULIC MACHINERY AND CAVITATION, VOLS I AND II, 1996, : 401 - 410
  • [30] ON THE EFFECT OF VOLUTE DESIGN ON UNSTEADY FLOW AND IMPELLER-VOLUTE INTERACTION IN A CENTRIFUGAL PUMP
    Litfin, Oliver
    Delgado, Antonio
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING - 2014, VOL 1B: SYMPOSIA, 2014,