PIV investigations of the flow field in the volute of a rotary blood pump

被引:11
|
作者
Sankovic, JM
Kadambi, JR
Mehta, M
Smith, WA
Wernet, MP
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] NASA, John H Glenn Res Ctr, Cleveland, OH 44135 USA
[3] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Cleveland, OH 44106 USA
[4] Cleveland Clin Fdn, Dept Biomed Engn, Lerner Res Ctr, Cleveland, OH 44195 USA
关键词
D O I
10.1115/1.1789529
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indecies of the fluid, the pump casing, and the impeller were matched to,facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 12 kPa and at a maximum flow condition. Four hundred data pairs were used,for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately +/-2.9%.
引用
收藏
页码:730 / 734
页数:5
相关论文
共 50 条
  • [1] Experimental investigation of internal flow field in the volute of a centrifugal pump by PIV
    Zhu, Hongwu
    Xue, Dunsong
    Dong, Shouping
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 1995, 16 (04): : 440 - 443
  • [2] PIV measurements of the unsteady flow structures in a volute centrifugal pump at a high flow rate
    Jens Keller
    Eduardo Blanco
    Raúl Barrio
    Jorge Parrondo
    Experiments in Fluids, 2014, 55
  • [3] PIV measurements of the unsteady flow structures in a volute centrifugal pump at a high flow rate
    Keller, Jens
    Blanco, Eduardo
    Barrio, Raul
    Parrondo, Jorge
    EXPERIMENTS IN FLUIDS, 2014, 55 (10)
  • [4] Evaluation of hydraulic radial forces on the impeller by the volute in a centrifugal rotary blood pump
    Boehning F.
    Timms D.L.
    Amaral F.
    Oliveira L.
    Graefe R.
    Hsu P.-L.
    Schmitz-Rode T.
    Steinseifer U.
    Artificial Organs, 2011, 35 (08) : 818 - 825
  • [5] PIV measurements of flow in a centrifugal blood pump: Steady flow
    Day, SW
    McDaniel, JC
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (02): : 244 - 253
  • [6] Application of PIV for the flow field measurement in a mixed-flow pump
    Inoue, Y.
    Nagahara, T.
    26TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, PTS 1-7, 2013, 15
  • [7] Flow Field Analysis of a Centrifugal Rotary Blood Pump under Active Speed Modulations
    Huang F.
    Wang C.
    Ruan X.
    1600, Chinese Mechanical Engineering Society (32): : 2915 - 2923
  • [8] PIV measurements of intake flow field in axial-flow pump
    Liu, Chao
    Liang, Haojie
    Jin, Yan
    Yang, Fan
    Chen, Feng
    Yang, Hua
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2015, 46 (08): : 33 - 41
  • [9] PIV experimental study on the flow field characteristics of axial flow blood pump under three operating conditions
    Xiao, Zhiyong
    Tan, Jianping
    Wang, Shuai
    Yu, Zheqin
    Wu, Weiqiang
    JOURNAL OF ENGINEERING-JOE, 2019, (13): : 155 - 158
  • [10] PIV Experimental Study of the Axial Flow Blood Pump's Internal Flow Field Under Pulsatile Condition
    Wang Shuai
    Tan Jianping
    Yu Zheqin
    Xiao Zhiyong
    Wu Weiqiang
    Cheng Lizhi
    4TH INTERNATIONAL CONFERENCE ON APPLIED MATERIALS AND MANUFACTURING TECHNOLOGY, 2018, 423