摘要
We introduce a new nonradioactive, chromogenic label based on 4-hydroxyazobenzene-2-carboxylic acid (HABA), which is suitable for bioanalytical application, e.g., detection, localization, isolation, and purification. The HABA label is superior to other systems where it is difficult to separate labeled from unlabeled molecules or to determine the amount of label. HABA is readily detected spectroscopically by its absorption at 350 nm or by its interaction with avidin that results in a red shift to 500 nm. The HABA reagents described can be conjugated to a variety of functional groups on biomolecules and purified thereafter by affinity chromatography on an avidin column. The interaction of the HABAylated biomolecules with their corresponding targets is detected with high-affinity anti-HABA antibodies or with avidin. The nonradioactive, chromogenic HABA-based reagents form a homogeneous system that can complement or replace systems where facile quantification of the label is desired. (C) 2000 Academic Press.
引用
收藏
页码:354 / 366
页数:13
相关论文
共 50 条
  • [21] CONTROLLED DEPOSITION OF GLUCOSE-OXIDASE ON PLATINUM-ELECTRODE BASED ON AN AVIDIN-BIOTIN SYSTEM FOR THE REGULATION OF OUTPUT CURRENT OF GLUCOSE SENSORS
    HOSHI, T
    ANZAI, J
    OSA, T
    ANALYTICAL CHEMISTRY, 1995, 67 (04) : 770 - 774
  • [22] A Novel Method for Assessment of Dynamic Concentration of Exogenous Protein in Serum: an Antibody-independent Sandwich System Based on Avidin-biotin Interaction
    Yu Ying-Xin
    Liu Yan-Jun
    Jiao De-Long
    Wen Li-Yan
    Xu Jiang-Ping
    Fu Ning
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2013, 40 (03) : 266 - 272
  • [23] Highly sensitive and rapid detection of porcine circovirus 2 by avidin-biotin complex based lateral flow assay coupled to isothermal amplification
    Jang, Minju
    Kim, SeJin
    Song, Junkyu
    Kim, Sanghyo
    ANALYTICAL METHODS, 2021, 13 (38) : 4429 - 4436
  • [24] VISUAL AND REAL-TIME BIOSENSOR BASED ON PLASMONIC METAMATERIALS FOR BIOTIN-AVIDIN-SYSTEM DETECTION
    Zhu, Jia
    Lin, Guanzhou
    Wang, Runhua
    Huang, Yun
    Chen, Zhuojie
    Chen, Xiaoyu
    Liu, Peimin
    Wu, Wengang
    2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 1132 - 1135
  • [25] Avidin-biotin system:: a small library of cysteine biotinylated derivatives designed for the [99mTc(N)(PNP)]2+ metal fragment
    Bolzati, Cristina
    Caporale, Andrea
    Agostini, Stefania
    Carta, Davide
    Cavazza-Ceccato, Mario
    Refosco, Florenzo
    Tisato, Francesco
    Schievano, Elisabetta
    Bandoli, Giuliano
    NUCLEAR MEDICINE AND BIOLOGY, 2007, 34 (05) : 511 - 522
  • [26] DETECTION OF MONOCLONAL FAB ANTIBODY FRAGMENTS BOUND TO LEUKOCYTE ANTIGENS - OPTIMIZATION OF THE AVIDIN-BIOTIN SYSTEM FOR QUANTITATIVE MEMBRANE-ELISA AND CELL-ELISA
    ZIERZ, R
    MONTZ, H
    BAUMGARTEN, H
    IMMUNOBIOLOGY, 1986, 173 (2-5) : 321 - 322
  • [27] Polymerase Chain Reaction Coupling with Magnetic Nanoparticles-Based Biotin-Avidin System for Amplification of Chemiluminescent Detection Signals of Nucleic Acid
    Li, Zhiyang
    He, Lei
    He, Nongyue
    Deng, Yan
    Shi, Zhiyang
    Wang, Hua
    Li, Song
    Liu, Hongna
    Wang, Zhifei
    Wang, Daxin
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2011, 11 (02) : 1074 - 1078
  • [28] Preparation and fluorescence properties of fluorophore-labeled avidin-biotin system immobilized on Fe3O4 nanoparticles through functional indolequinone linker
    Hirata, Nao
    Tanabe, Kazuhito
    Narita, Asako
    Tanaka, Kazuo
    Naka, Kensuke
    Chujo, Yoshiki
    Nishimoto, Sei-ichi
    BIOORGANIC & MEDICINAL CHEMISTRY, 2009, 17 (11) : 3775 - 3781
  • [29] COMPARATIVE QUANTITATION OF ABSCISIC-ACID IN PLANT-EXTRACTS BY GAS-LIQUID-CHROMATOGRAPHY AND AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY USING THE AVIDIN-BIOTIN SYSTEM
    LEROUX, B
    MALDINEY, R
    MIGINIAC, E
    SOSSOUNTZOV, L
    SOTTA, B
    PLANTA, 1985, 166 (04) : 524 - 529
  • [30] Avidin-biotin system-based enzyme multilayer membranes for biosensor applications: Optimization of loading of choline esterase and choline oxidase in the bienzyme membrane for acetylcholine biosensors
    Chen, Q
    Kobayashi, Y
    Takeshita, H
    Hoshi, T
    Anzai, J
    ELECTROANALYSIS, 1998, 10 (02) : 94 - 97